Sei sulla pagina 1di 1

DIgSILENT

u=1,00 p.u.

CT BAGUA 10kV

P=-1,20 MW
Q=-0,50 Mvar
loading=54,94 %

-2

u=1,02 p.u.

P=1,49 MW
Q=0,69 Mvar
loading=5,99 %

Load Bagua G 10kV

P=0,50 MW
Q=0,24 Mvar
=

Load BAGUA G 22.9kV

P=-0,45 MW
Q=-0,26 Mvar
loading=82,37 %

P=0,45 MW
Q=0,28 Mvar
loading=82,37 %

MUYO
P=3,59 MW
Q=2,08 Mvar
loading=73,46 %

P=-4,37 MW
Q=-2,78 Mvar
loading=6,35 %

P=-1,60 MW
Q=-0,77 Mvar
loading=73,46 %

BAGUA 10kV

P=1,60 MW
Q=0,77 Mvar
=

u=1,04 p.u.

Load Bagua 10kV

Load NJaen 22.9kV

u=0,97 p.u.

P=0,40 MW
Q=-0,00 Mvar
=

N JAEN 22.9kV(1)

NJAEN 60kV

P=-0,00 MW
Q=-0,00 Mvar
loading=6,89 %

Lne Cutervo-Jaen

Lne Carhuaquero cutervo

P=-0,72 MW
Q=2,04 Mvar
loading=1,69 %

Red Exter..

CARHUAQUERO

u=0,98 p.u.

CARHUAQUERO 138kV

P=0,30 MW
Q=0,10 Mvar
loading=9,14 %

u=0,98 p.u.

P=-0,40 MW
Q=0,00 Mvar
loading=12,19 %

P=1,03 MW
Q=-1,92 Mvar
loading=1,71 %

P=-1,02 MW
Q=1,94 Mvar
loading=1,71 %

P=0,72 MW
Q=-2,04 Mvar
loading=1,69 %

P=0,72 MW
Q=-2,04 Mvar
loading=6,89 %

P=4,46 MW
Q=2,89 Mvar
loading=76,49 %

P=0,40 MW
Q=0,20 Mvar
loading=30,02 %

u=0,96 p.u.

P=-0,72 MW
Q=2,06 Mvar
loading=6,89 %

P=-4,46 MW
Q=-2,54 Mvar
loading=76,49 %

P=2,10 MW
Q=1,02 Mvar
=

u=0,98 p.u.

-0,72 MW
2,06 Mvar
-0,33

MUYO 1

P=4,46 MW
Q=2,54 Mvar
loading=6,35 %

P=0,78 MW
Q=0,70 Mvar
loading=1,65 %

Load BAGUA 22.9kV

CARHUAQUERO 22.9kV

u=0,99 p.u.

Lne 60 BAGUA - MUYO

P=-1,03 MW
Q=1,92 Mvar
loading=12,19 %

CUTERVO138kV

MUYO 2

P=1,43 MW
Q=-1,90 Mvar
loading=12,19 %

-1

P=2,43 MW
Q=1,55 Mvar
loading=72,00 %

CH_MUYO_G2

P=-0,78 MW
Q=-1,09 Mvar
loading=1,65 %

JAEN- A

u=0,98 p.u.

CH_MUYO_G1

~
G

BAGUA G(2)

u=1,01 p.u.

BAGUA

~
G

~
G

Lne BAGUA G - CT BAGUA G

P=-1,45 MW
Q=-0,68 Mvar
loading=5,99 %

u=0,98 p.u.

BAGUA 60kV

u=1,00 p.u.

P=-1,99 MW
Q=-0,93 Mvar
loading=73,46 %

P=0,25 MW
Q=0,12 Mvar
=

CT BAGUA G-G1(1)
CT_BAGUA_G GT2
P=0,45 MW
Q=0,28 Mvar
loading=84,04 %

BAGUA 22.9kV

P=1,20 MW
Q=0,56 Mvar
loading=54,94 %

Lne 60 JAEN BAGUA

P=0,45 MW
Q=0,28 Mvar
loading=82,37 %

BAGUA G

P=-0,45 MW
Q=-0,26 Mvar
loading=82,37 %

-3

~
G

P=0,45 MW
Q=0,28 Mvar
loading=84,04 %

BAGUA G 22.9kV
u=0,96 p.u.

BAGUA G(1)

u=1,02 p.u.

CT BAGUA G-G1
CT_BAGUA_G GT1

P=-0,40 MW
Q=-0,19 Mvar
loading=30,02 %

u=0,99 p.u.

P=-0,65 MW
Q=2,98 Mvar
loading=3,91 %

P=2,43 MW
Q=1,55 Mvar
loading=72,09 %

CH_MUYO_4.16kV

PSE_MUYO_22.9kV

P=0,40 MW
Q=0,19 Mvar
=

u=0,99 p.u.

NJAEN 138kV
Load Muyo

CARHUAQUERO 220kV

P=0,10 MW
Q=-0,00 Mvar
=

CUTERVO22.9kV

P=-0,20 MW
Q=-0,10 Mvar
loading=9,14 %

u=0,98 p.u.

P=0,20 MW
Q=0,10 Mvar
=

CUTERVO13.2kV

Lne 60 JAEN DJAEN

u=0,98 p.u.

u=1,00 p.u.

CH_L grande 001

~
G

CUTERVO

P=-0,10 MW
Q=0,00 Mvar
loading=9,14 %

LONGA GRANDE 0.4k

P=0,15 MW
Q=0,09 Mvar
loading=69,97 %

Load Cutervo 22.9kV

Load Cutervo 13.2kV

JAEN 22.9k

~
G

CH_L grande 002

LONGA GRANDE 22.9k

P=0,15 MW
Q=0,09 Mvar
loading=69,97 %

u=0,96 p.u.

TR2_Longa grande
P=0,30 MW
Q=0,18 Mvar
loading=77,42 %

P=-0,30 MW
Q=-0,17 Mvar
loading=77,42 %

u=0,99 p.u.
Lne L G_Jaen

Lne Longa Grande_Jaen


P=0,30 MW
Q=0,17 Mvar
loading=1,44 %

P=-0,21 MW
Q=0,01 Mvar
loading=0,78 %

P=-0,29 MW
Q=-0,25 Mvar
loading=1,44 %

Diagrama Unifiliar
Sistema Electrico JAEN - BAGUA

P=0,21 MW
Q=-0,01 Mvar
loading=0,78 %

P=0,50 MW
Q=0,24 Mvar
=

P=0,66 MW
Q=-3,08 Mvar
loading=3,91 %

JAEN

JAEN 60kV

P=1,63 MW
Q=-1,80 Mvar
loading=84,22 %

u=0,97 p.u.
P=-0,66 MW
Q=3,08 Mvar
loading=84,22 %

-4

Load Chamaya

P=-1,83 MW
Q=1,81 Mvar
loading=9,99 %

Lne JAEN-QUANDA 1

~
G

P=1,30 MW
Q=0,50 Mvar
loading=46,43 %

TR2_QUANDA
P=2,60 MW
Q=1,00 Mvar
loading=75,87 %

CH_QUANDA002

P=-2,60 MW
Q=-0,84 Mvar
loading=75,87 %

Lne JAEN-QUANDA 2B

Lne JAEN-QUANDA 2A
P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

P=0,00 MW
Q=0,00 Mvar
=

P=0,00 MW
Q=0,00 Mvar
=

Load_Huarango

Load_BellV_Pirias _Puquio

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

JAEN 10kV
P=-0,97 MW
Q=-0,92 Mvar
loading=84,22 %

u=1,04 p.u.

CH_PELOTA
P=4,70 MW
Q=2,28 Mvar
=

P=-1,00 MW
Q=-0,59 Mvar
loading=37,53 %

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

P=0,00 MW
Q=0,00 Mvar
=

Load

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

CT_JAEN_GALCO_4.16kV

Ramas

Tensin, Magnitud [p.u.] Potencia Activa [MW]


Potencia Reactiva [Mvar]

Red Externa
Potencia Activa
Potencia Reacti

Mximo Nivel de Carga [%] Factor de Poten

u=1,07 p.u.

TR2 H LA PELOTA
P=-2,80 MW
Q=-0,83 Mvar
loading=71,50 %

P=2,80 MW
Q=1,00 Mvar
loading=71,50 %

P=1,40 MW
Q=0,42 Mvar
loading=11,24 %

P=1,40 MW
Q=0,50 Mvar
loading=49,55 %

CH_PELOTA_G1

Lne 10 JAEN-PELOTA(1)

P=1,40 MW
Q=0,50 Mvar
loading=74,33 %

u=1,05 p.u.

CH_PELOTA_G2

P=1,00 MW
Q=0,62 Mvar
loading=37,65 %

G
~

P=0,00 MW
Q=0,00 Mvar
=

CT_JAEN_GALCO
Load_San Ignacio

UNCP
FIE

Flujo Carga Balanceada


Nodos

P=1,40 MW
Q=0,42 Mvar
loading=11,24 %

TR2 CT JAEN
P=1,00 MW
Q=0,62 Mvar
loading=37,53 %

Load_2

P=-1,37 MW
Q=-0,38 Mvar
loading=11,24 %

Lne 10 JAEN-PELOTA
Load Jaen 10kV

u=1,04 p.u.

PELOTA 10kV
P=-1,37 MW
Q=-0,38 Mvar
loading=11,24 %

PowerFactory 14.0.524

G
~

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

G
~

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

P=1,30 MW
Q=0,50 Mvar
loading=46,43 %

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

Compensacin/Filtro

CH_QUANDA001

~
G

P=-0,00 MW
Q=2,34 Mvar
=

u=1,05 p.u.

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

P=0,00 MW
Q=0,00 Mvar
=

u=1,08 p.u.

CT QUANDA

Lne JAEN-QUANDA 2D

P=2,60 MW
Q=-1,49 Mvar
loading=9,99 %

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

Lne JAEN-QUANDA 2C

QUANDA 22.9kV

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

P=0,00 MW
Q=0,00 Mvar
loading=0,00 %

P=0,00 MW
Q=0,00 Mvar
=

Lne JAEN-QUANDA 2G

Lne JAEN-QUANDA 2F

Lne JAEN-QUANDA 2E

Load_coipa y chirinos

Flujo de Potencia

Proyecto:MaxDem C-2

"Coordinacion de Proteccion del Sistema Electrico


Central Hidroelectrica Quanda_subestacion Jaen"
Bach.Alex Medina Gaspar

Grfica: JAEN BAGUA


Fecha:
Anexo:

Potrebbero piacerti anche