Sei sulla pagina 1di 2

DATE: 04/10/2013 valve nos.

D1 D2 D3 D4 D5 D6 D7 local NOT OK OK OK OK OK OK OK remote OK OK OK OK OK OK NOT OK

BEFORE HP CV AFTER HP CV AFTER HP CV EXTRACTION LINE TURBINECASING AFTER LP CV BALANCE LINE

Remarks: 1.) Drain D1: During local operation of valve both open and close push button required to press continiously. But travel of val 2.) Drain D7: during remote operation valve could not open and both open and close feedback persist on control panel. ACTION: DEFECT OF BOTH PROBLEM ENTERED IN SAP.

niously. But travel of valve is found OK in both opening and closing operation. t on control panel.