Sei sulla pagina 1di 39

DISEO DE SEPARADO

DATOS BASICOS PARA EMPESAR


PRESION (Kg/cm2)

99.05

1408.491

TEMPERATURA C

40

104

FLOWRATE(Kgmole/h)

154.46

ENTALPIA(KW)

296.8

DATOS OBTENIDOS EN SIMULADOR


WG

30719.86
18.8125

kg/h
Lb/s

WL

0.0331

lb/s

0.98771

PM g

11.2

2.5533

Lb/ft3

62.1781

Lb/ft3

0.01699

cp

DATOS OBTENIDOS EN BASE A NORMAS I CRITERIOS ESTABLECIDOS


Dp
100
m
TR

0.35

MIN

SEO DE SEPARADOR VERTICAL

(*) INGRESAR DATOS

CALCULO DE LA K.

wl/wg 0.I
0.1 wl/wg 1
wl/wg >1

k1
k2
k3

CALCULO DEL PESO MOLECULAR DE LA MEZCLA


COMP.DE LA C.32 FRAC MOLAR
PM
H2
1.24879936
0.619481 2.01588
N2
0.227781 28.01348 6.38093849
CH4
0.102915 16.04246 1.65100977
Ar
39.948
1.88222992
0.047117
NH3
0.000146 17.03056 0.00248646
H20
0.00256 18.01528 0.04611912
PM mz

CALCULO DE LA VELOCIDADA DE EROSION


VE
C
m

62.52922385 ft/s
100
2.55760766 lb/ft3

0.35
0.25
0.2

11.2

WL
WG

0.0331 Lb/s
18.8125 Lb/s

*conforme al siguiente criterio selecciona tu k


k

wl/wg
K1
K2
K3

0.002
0.35
NO
NO

0.35

selecciona tu k

CALCULOS DEL DISEO


DATOS
SIMBOLOS
DEN LIQ
L
DEN GAS
V
FM LIQ
WL
FM GAS
WG
TIEMPO DE R.
TR
CTE S-B
K

VALOR
UNIDADAD
62.1781
lb/ft3
2.5533
lb/ft3
0.0331
lb/s
18.8125009
lb/s
5
minutos
0.35
CTE

1-CALCULO DE LA VELOCIADA DE DISEO

1.691

ft/seg

2-CALCULO DEL FLUJO VOLUMETRICO DEL GAS

7.368 ft3/seg
3-CALCULO DEL AREA

4.356 ft2
4-CALCULO DEL DIAMETRO

2.355 FT

28.261 IN

5-CALCULO DEL FLUJO VOLUMETRICO DEL LIQUIDO

0.001 ft3/seg
6-CALCULO DEL VOLUMEN DEL LIQUIDO

0.160 ft3
7-CALCULO DE LA HALTURA DEL LIQ EN EL RECIPIENTE

30

0.033 ft

0.390 IN

8-CALCULO DE LA DENSINDAD DE LA MESCLA

2.558 lb/ft3
9-CALCULO DE LA VELOCIDADD DE BOQUILLA

50.0233791 ft/seg
30 ft/seg
10-CALCULO DEL DIAMETRO DE LA BOQUILLA

1.75684257 FT

21.08211081 IN

11-CALCULO DE LA VELOCIDAD MAXIMA DE LA SALIDA DEL GAS DEL SEPARADOR.


50.0655584 FT/SEG
60 FT/SEG.
12-CALCULO DE LA VELOCIDAD DEL LIQUIDO A LA SALIDA DEL SEPARADOR
10.1454488 ft/seg
3 ft/seg
13-CALCULO DEL DIAMETRO DE BOQUILLA DEL GAS DE SALIDA
0.395413298 FT

4.744959577 IN
6
0.5
14-CALCULO DEL DIAMETRO DE BOQUILLA DE SALIDA DEL LIQUIDO

0.045093137 ft

0.541117648 IN

"DISEO DE SEPARADOR BIFASICO"

4.1-RECALCULO DE AREA:
4.909 FT2
IN

2.500 FT
0.762 m

24 IN

2 FT

1.04111765 IN

2 IN

0.16666667 FT

RESULTADOS
NIVEL H
h0

PDVSA
ESPESIFICACION DE DISEO
HO=DV/4

RESULTADO
0.625

h1

HI=(DV-D1)/2-HO

h2

H2=6"=0.5

0.5

h3

H3=0.6DV O 3"(MIN)

1.5

h4

H4=DI

h5

H5=0.3DV O 2"(MIN)

h6

H6=CAP.LIQ.=1"(MIN)

h7

N/A

h0

HO=DV/4

*********

dv
l/dv

**********

RANGO

0.375

2
0.75
0.032534333
0
0.625

ft
m

2.5 L/DV 6

6.407534333
1.953016465
2.5
2.56301

dentro del rango

DIMENCIONES DEL SEPARADOR

DIAMETRO

0.762

metros

LONGITUD

1.9530

metros

DIMENCIONES DEL SEPARADOR


160-LF
DIAMETRO
LONGITUD

0.83
0.83
1.8000
2.02
TI-PAG 107 T2-PAG-348

0.395

DIMENCIONES DEL SEPARADOR


DIAMETRO

2.500 pies
0.762 metros

LONGITUD

6.40753433 pies
1.953 metros
2

2.500

PDVSA

AJUSTANDO SEGN FIG


0.625

0.625

0.375

0.375

0.5

0.5

1.5

1.5

0.75

0.03253433

0.625

0.625
L

USTANDO SEGN FIGURA

8.625
2.6289
L/D
2.500
0.762

3.45
DENTRO DEL RANGO

KR

Potrebbero piacerti anche