ELECTRIC PRODUCTS
APRIL 2012
www.voltex.co.za
www.lsis.biz
CONTENTS
SUSOL/METASOL SERIES
2, 3 and 4 pole series up to 1600AF
Rated ambient temperature at 40C calibrated for
50C available
page 6
METASOL SERIES
page 8
METASOL SERIES
3 and 4 pole series up to 800AF Mini-contactors available
AC/DC common use coil from 100AF
SUSOL/METASOL SERIES
65, 85 and 150 kA breaking capacity
High funtional digital trip relays
CE marked and Marine classification
page 50
SUSOL SERIES
Type
BKN
BKN-c
BKN-b
BKH
BKP
BFN
Protection
Rated current
Characteristic
B, C, D curve
B, C, D curve
C, D curve
B, C, D curve
1P, 2P, 3P
Poles
1p+N
1P, 2P, 3P
Breaking capacity
1pole
1pole
1pole
2~4pole
2~4pole
2~4pole
1A
2A
3A
4A
6A
10A
6kA at
230/400VAC
16A
20A
6kA at
400VAC
10kA at
230/400VAC
4.5kA at
230VAC
10kA at
400VAC
10kA at
220/240VAC
25A
32A
40A
50A
63A
80A
10kA at
230/400VAC
100A
10kA at
400VAC
125A
Standard
IEC 60898/60947-2
IEC 60898/60947-2
IEC 60947-2
Type of trip
Electrical endurance
6000 operations
8000 operations
6000 operations
20000 operations
10000 operations
Mount
Plug-in
Width
Terminal
Auxiliary switch, AX
Optional
1 changeover contact
1 changeover contact
6A at 24VDC, 2A at 48VDC
2A at 48VDC, 1A at 125VDC
1A at 130VDC
Lug terminal
Lug terminal
9mm wide
8.8mm wide
IEC 60898
IEC 60947-2
Dimension
See drawing 1
See drawing 2
See drawing 3
See drawing 4
See drawing 5
Characteristic curve
See curve 1
See curve 1
See curve 1
See curve 1
See curve 2
(33)
23.5
(14)
45
60
68
17.8
63
81
56
82
65
45
37
82
63
37
45
(19)
60
5
43.8
60
68
65
17.8
75
75
Type
RKP
RKS
RKS-b
RKN
Protection
Rated current, In
3(C,D),6,10,16,20,25,32A(B,C,D curve)
RKN-b
Ground fault
25, 32, 40, 63A
32 KGRc
32KGRd
Type
BKD
Rated current, In
Number of poles
Rated voltage
240/415VAC
Standard
Non-operating, l no
0.5l n
0.5l n
0.5l n
0.5l n
Electrical
Number of poles
1P + N
1P + N
2, 4 pole
2 pole
endurance
Rated voltage
230VAC
230VAC
230VAC(2p), 230/400VAC(4p)
110/220VAC
Mount
0.1 sec.
0.3 sec.
0.1 sec.
0.03 sec.
Width
Standard
IEC 61009
IEC 61009
IEC 61008
Terminal
Dimension
See drawing 4
Ground fault
Electro-magnetic
Electro-magnetic
Electro-magnetic
Electronic
Overcurrent
Thermal-magnetic
Thermal-magnetic
N.A
Bimetallic
4.5kA
10kA
Type of trip
Breaking Capacity
1.5kA
20000 operations
10000 operations
2.5kA
Electrical endurance
20000 operations
4000 operations
6000 operations
6000 operations
Mount
Width
35mm
Terminal
Dimension
See drawing 1
See drawing 5
See drawing 2
See drawing 3
Characteristic curve
See drawing 6
See drawing 7
See curve 1
Drawing 1 : Type RKP
(22)
18
(17)
19
50
78
55
24
45
60
82
111
81
45
35
37
IEC 60947-3
40, 50, 63A
23
23
(22)
18
8.9
18
27
20
35.6
21
22
N
(13)
45
61
74
46
72
36
54
108
42.7
68
82
82
68
45
36
21
60
82
5N
73.5
45
13
59.8
37
60
68
70
22
45
22
23
(10)
5
17.8
45
60
70
PRODUCT DESCRIPTION
The BKS surge protective device is applied to the alternating current 50/60Hz, 220V/380V power system and provides
the protection from the surge overvoltage of an electric system.
Moreover, it is the protection element (MOV) replacement type and is the product with convenience and economic
efficiency. However, only the protection module is provided so that separate components have to be combined
according to the site conditions. If the protective device is normal, the display becomes green. The display becomes
red after operation (abnormal or after an accident).
PRODUCT RATING
Type
BKS-A
BKS-B
BKS-C
Pole
BKS-D
BKS-E
1, 2, 3, 4 Pole
AC 220V
AC 220V
AC 220V
AC 380V
AC 380V
AC 320
AC 320V
AC 320V
AC 420V
AC 460V
1.0kA
1.2kA
1.5kA
2.0kA
2.3kA
10kA
20kA
40kA
60kA
70kA
) kA
Response time ns
<25 ns
-40 ~ +80 C
Usable frequency Hz
50/60Hz
Attachment type
Protection class
Alarm Contact
No
Class II
No
No
No
No
* The surge protective device starts to operate above the maximum continuous operating voltage Uc (MCOV).
Drawing
Operation state
display window
MOV System unit
Common bar
DIN-rail mounting bed
www.voltex.co.za
MC type
Magnetic Contactors
Frame size
18AF
Type
screws clamp terminals
22AF
40AF
65AF
100AF
MC-6a
MC-9a
MC-12a
MC-18a
MC-9b
MC-12b
MC-18b
MC-22b*
MC-32a
MC-40a
MC-50a
MC-65a
MC-75a
MC-85a
MC-100a
Number of poles
3pole
3pole
690V
690V
690V
690V
690V
690V
690V
1000V
1000V
1000V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
6kV
6kV
8kV
8kV
8kV
Rated frequency
Rated impulse withstand voltage, Uimp
Maximum operating rate in operating cycles per hour (AC3)
Durability
Current
and
3pole
3pole
Mechanical
15 mil. operations
15 mil. operations
12 mil. operations
12 mil. operations
Electrical
2 mil. operations
2 mil. operations
power
UL rating
(50/60Hz)
3pole
2 mil. operations
25
25
25
32
25
25
32
40
50
60
70
100
110
135
160
200/240V
kW
A
2.2
9
2.5
11
3.5
13
4.5
18
2.5
11
3.5
13
4.5
18
5.5
22
7.5
32
11
40
15
55
18.5
65
22
75
25
85
30
105
380/440V
kW
A
3
7
4
9
5.5
12
7.5
18
4
9
5.5
12
7.5
18
11
22
15
32
18.5
40
22
50
30
65
37
75
45
85
55
105
500/550V
kW
A
3
6
4
7
7.5
12
7.5
13
4
7
7.5
12
7.5
13
15
20
18.5
28
22
32
30
43
33
60
37
64
45
75
55
85
690V kW
A
3
4
4
5
7.5
9
7.5
9
4
6
7.5
9
7.5
9
15
18
18.5
20
22
23
30
28
33
35
37
42
45
45
55
65
Continuous current
25
25
25
32
25
25
40
40
50
60
70
100
110
135
160
HP
HP
0.5
1.5
0.5
1.5
0.72
2
1
3
0.5
1.5
0.75
2
1
3
2
3
2
5
3
7.5
3
10
5
15
5
15
7.5
15
10
20
200~208V HP
Three 220~240V HP
2
3
2
3
3
5
5
7.5
2
3
3
5
5
7.5
7.5
10
7.5
10
15
15
20
25
25
30
25
30
30
40
30
40
phase 440~480V HP
550~600V HP
5
7.5
5
7.5
7.5
10
10
15
5
7.5
7.5
10
10
15
15
20
20
25
30
30
40
50
50
60
50
60
60
75
75
75
NEMA size
00
00
00
00
Single 110~120V
phase 220~240V
Size
and
AC Weight kg
control
Size (W x H x D) mm
0.33
45 x 73.5 x 79
0.34
45 x 73.5 x 86
0.4
45 x 83 x 90
0.9
55 x 106 x 119
1.6
70 x 140 x 135.8
weight
DC Weight kg
control
Size (W x H x D) mm
0.5
45 x 73.5 x 113.7
0.51
45 x 73.5 x 117.7
0.6
45 x 83 x 117.1
1.2
55 x 106 x 146.4
2.6
70 x 140 x 172.3
1a or 1b
UA-1
1a1b
UA-1
UA-1
UA-1
UA-1
UA-2, UA-4
UA-2, UA-4
UA-2, UA-4
UA-2, UA-4
UA-2, UA-4
Auxiliary (standard)
Side mount
Auxiliary
Front mount
(Note) Minimum conduct of Auxiliary contactor is DC 17V 5mA.
MT type
Thermal Overload Relays
MT-12/
Type
MT-32/
MT-32/
MT-63/
MT-95/
690V
690V
690V
690V
690V
690V
690V
690V
690V
690V
6kV
6kV
6kV
6kV
6kV
Trip class
10A, 20
10A, 20
10A, 20
10A, 20
10A, 20
Setting range
0.1~18A
0.1~40A
0.1~40A
4~65A
7~100A
Weight kg
0.1
0.17
0.17
0.31/0.33
0.48/0.5
Size (W x H x D) mm
45 x 73.2 x 63.7
45 x 75 x 90
45 x 75 x 90
55 x 81 x 100
70 x 97 x 110
Size
and
weight
* The safety cover of magnetic contactor and thermal overload relay is optional.
10
11
MC type
Magnetic Contactors
Frame size
225AF
150AF
Type
screws clamp terminals
400AF
800AF
MC-130a
MC-150a
MC-185a
MC-225a
MC-265a
MC-330a
MC-400a
MC-500a
MC-630a
MC-800a
Number of poles
3pole
3pole
3pole
3pole
690V
690V
690V
690V
1000V
1000V
1000V
1000V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
8kV
8kV
8kV
8kV
Mechanical
5 mil. operations
5 mil. operations
5 mil. operations
Electrical
1 mil. operations
1 mil. operations
1 mil. operations
Rated frequency
Rated impulse withstand voltage, Uimp
Maximum operating rate in operating cycles per hour (AC3)
Durability
Current
and
power
UL rating
(50/60Hz)
160
210
230
275
300
350
450
580
660
900
200/240V
kW
A
37
130
45
150
55
185
75
225
80
265
90
330
125
400
147
500
190
630
220
800
380/440V
kW
A
60
130
75
150
90
185
132
225
147
265
160
330
200
400
265
500
330
630
440
800
500/550V
kW
A
60
90
70
100
110
180
132
200
147
225
160
280
225
350
265
400
330
500
500
720
690V kW
A
55
60
55
60
110
120
140
150
160
185
200
225
250
300
300
380
400
420
500
630
Continuous current
160
210
230
275
300
350
450
580
660
900
HP
HP
10
20
15
25
15
30
15
40
200~208V HP
Three 220~240V HP
40
40
40
50
60
60
60
75
75
100
100
125
125
150
150
200
200
250
200
300
phase 440~480V HP
550~600V HP
75
75
100
75
125
125
150
150
200
200
250
250
300
300
400
400
500
500
600
600
NEMA size
Single 110~120V
phase 220~240V
Size
and
AC Weight kg
control
Size (W x H x D) mm
2.4
95 x 158 x 132
weight
DC Weight kg
control
Size (W x H x D) mm
2.3
95 x 158 x 132
Auxiliary (standard)
Side mount
Auxiliary
Front mount
5.4
9.2
22.4
UA-1
2a2b
AU-100 (Max.4NO4NC)
2a2b
AU-100 (Max.4NO4NC)
2a2b
AU-100 (Max.4NO4NC)
UA-2, UA-4
MT type
Thermal Overload Relays
MT-150/
Type
MT-225/
MT-400/
MT-800/
690V
690V
690V
690V
690V
690V
690V
690V
6kV
6kV
6kV
6kV
10A, 20
10A, 20
10A, 20
10A, 20
34~150A
65~240A
85~400A
200~800A
Weight kg
0.67
2.5
2.6
11.5
Size (W x H x D) mm
95 x 109 x 113
* The safety cover of magnetic contactor and thermal overload relay is optional.
12
13
MC type
Magnetic Contactors
Frame size
18AF
Type
MC-6a/4
MC-9a/4
MC-12a/4
MC-18a/4
MC-22a/4
40AF
MC-32a/4
85AF
MC-40a/4
MC-50a/4
MC-65a/4
MC-75a/4
Number of poles
4pole
4pole
4pole
4pole
690V
690V
690V
690V
690V
690V
690V
1000V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
6kV
6kV
6kV
8kV
15 mil. operations
15 mil. operations
15 mil. operations
12 mil. operations
1 mil. operations
1 mil. operations
1 mil. operations
Rated frequency
Rated impulse withstand voltage, Uimp
Maximum operating rate in operating cycles per hour (AC1)
Durability
Mechanical
Electrical
Current
Thermal current
and
AC-1
power
MC-85a/4
25
25
25
40
40
50
60
80
100
110
135
kW
15
15
18
22
30
37
41
51
25
25
25
40
40
50
60
80
100
110
135
380/400V
kW
17
17
17
27
27
35
42
56
70
76
95
25
25
25
40
40
50
60
80
100
110
135
500/550V
kW
21
21
21
35
35
43
52
70
88
97
120
25
25
25
40
40
50
60
80
100
110
135
690V
kW
27
27
27
44
44
55
66
88
110
120
150
25
25
25
40
40
50
60
80
100
110
135
200/240V
UL rating
Continuous current
25
25
25
32
32
45
50
70
80
90
100
(50/60Hz)
Single 110~120V
HP
0.5
0.5
0.75
7.5
phase 220~240V
HP
1.5
1.5
7.5
10
15
15
200~208V HP
7.5
7.5
10
10
15
20
25
Three 220~240V
HP
7.5
7.5
10
10
15
20
25
30
phase 440~480V
HP
7.5
10
10
20
25
30
40
50
50
550~600V HP
7.5
7.5
10
15
15
20
25
30
40
50
50
NEMA size
00
00
Size
AC Weight
and
control
Size (W x H x D)
mm
weight
DC Weight
kg
control
Size (W x H x D)
Auxiliary (standard)
Auxiliary
14
22AF
kg
mm
0.33
0.4
0.59
1.2
45 x 73.5 x 79
47.2 x 80 x 86.8
59 x 83.5 x 94.5
91 x 123.5 x 117.8
0.5
0.5
0.7
1.29
45 x 73.5 x 110.7
47.2 x 80 x 113.2
59 x 83.5 x 121
91 x 123.5 x 117.8
Side mount
UA-1
AU-1
AU-1
AU-1
Front mount
AU-2, AU-4
AU-2, AU-4
AU-2, AU-4
AU-2, AU-4
15
MC type
Magnetic Contactors
Frame size
225AF
Type
MC-100a/4
MC-130a/4
MC-150a/4
400AF
MC-185a/4
MC-225a/4
MC-265a/4
MC-330a/4
800AF
MC-400a/4
MC-500a/4
MC-630a/4
4pole
4pole
4pole
690V
690V
690V
1000V
1000V
1000V
50/60Hz
50/60Hz
50/60Hz
8kV
8kV
8kV
5 mil. operations
Rated frequency
Rated impulse withstand voltage, Uimp
Maximum operating rate in operating cycles per hour (AC1)
Durability
Mechanical
Electrical
Current
Thermal current
and
AC-1
power
MC-800a/4
160
165
250
300
330
360
420
500
630
750
900
kW
57
60
76
87
100
115
135
160
245
255
310
150
155
200
230
260
300
350
420
630
660
800
380/400V
kW
106
110
142
165
185
215
250
300
450
470
570
150
155
200
230
260
300
350
420
630
660
800
500/550V
kW
132
137
180
205
230
265
315
375
560
590
710
150
155
200
230
260
300
350
420
630
660
800
690V
kW
165
170
225
255
290
335
390
470
710
740
900
150
155
200
230
260
300
350
420
630
660
800
200/240V
UL rating
Continuous current
160
160
210
230
275
300
350
450
580
660
900
(50/60Hz)
Single 110~120V
HP
7.5
10
15
15
15
phase 220~240V
HP
15
20
25
30
40
200~208V HP
30
40
40
60
60
75
100
125
150
200
200
Three 220~240V
HP
30
40
50
60
75
100
125
150
200
250
300
phase 440~480V
HP
60
75
100
125
150
200
250
300
400
500
600 *
550~600V HP
60
75
100
125
150
200
250
300
400
500
600 **
NEMA size
Size
AC Weight
and
control
Size (W x H x D)
mm
weight
DC Weight
kg
9.9
26.3
2a2b
2a2b
2a2b
Side mount
AU-100
AU-100
AU-100
Front mount
control
Auxiliary
kg
5.6
Size (W x H x D)
Auxiliary (standard)
mm
16
17
MINI CONTACTORS
6 TO 16A
Mini contactors
Fast-on type
6A
9A
12A
16A
GMC-6M
GMC-9M
GMC-12M
GMC-16M
DC coil
GMD-6M
GMD-9M
GMD-12M
GMD-16M
AC coil
GMC-6MF
GMC-9MF
GMC-12MF
GMC-16MF
GMD-6MF
GMD-9MF
GMD-12MF
GMD-16MF
AC coil
GMC-6MC
GMC-9MC
GMC-12MC
GMC-16MC
DC coil
GMD-6MC
GMD-9MC
GMD-12MC
GMD-16MC
AC coil
GMC-6MP
GMC-9MP
GMC-12MP
GMC-16MP
DC coil
GMD-6MP
GMD-9MP
GMD-12MP
GMD-16MP
kW
kW
20
kW
20
kW
20
2.2
12
15
380/440V
2.2
5.5
12
7.5
16
500/550V
3.7
5.5
690V
hp
hp
hp
hp
continuous current
1/2
1 *
1.5
2 **
240V
1.5
480V
7.5 ***
600V
7.5
00
120V
230V/240V
Model No.
00
00
AU-2M
Fast-on type
AU-2MF
AU-4M
AU-2MC
AU-4MF
AU-1M
AU-4MC
AU-1MF
AU-1MP
AU-1MC
(Note) * = 1/2 for cage clamp type, ** = 1.5hp for cage clamp type, *** = 5hp for cage clamp type
16AF : not approved from UL
Bimetallic style
Type GT
Differential
18
Setting
ranges (A)
GT-12M
0.1 - 0.16
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
1 - 1.6
1.6 - 2.5
2.5 - 4
4-6
5-8
6-9
7 - 10
9 - 13
13 - 16
GTK-12M
Non-differential (3-heater)
GTH-12M/3
Non-differential (2-heater)
GTH-12M
DMP06-T/Ta
DMP06-T/Ta
Tunnel type
Protection
Over current
Phase failure
3 sec.
Reverse phase
Asymmetry
5 sec.
Stall
5 sec.
Lock
Under current
3 sec.
Ground fault
Within 50ms
Alarm
0.5~6
5~60
0.5~6
5~60
Motor capacity
220~240V
0.09~0.75
1.1~11
0.09~0.75
1.1~11
(kW)
380~440V
0.12~1.5
2.2~22
0.09~1.5
2.2~22
Time setting
Definite
Delay in starting
0~60sec
range (sec)
Time
Delay in operating
0~30sec
Inverse time
0~60sec
Reset
Tolerance
Manual reset
Current
5%
Time
5% (or 0.5sec)
Operating power
Voltage
AC 190~250V
(Note 3)
Frequency
60Hz (50Hz)
OL
2-SPST
AL
SPST
Aux. contact
Insulation resistance
1.2 x 50
2.5kV/5min
Temperature
Operation
-25~70 C
Storage
-30~80 C
Humidity
Display
Base for
separate mount
DMP60-S/Sa
-T/Ta
Operation time
Environment
Overload Relays
DMP06-S/Sa
Panel mount
DMP
Screw type
20
1.5
-S/Sa
Wiring
200/240V
Ratings / UL 508
three phase
DMP
DC coil
AC1
single phase
AC coil
Ratings / IEC60947-4
AC3
Mounting type
Bar-Graph
(Note 1) In extension type, the digital EMPR is calibrated with combining the display past and main body so,
please be cautious not to combine the display part main body with different part No.
(Note 2) Instantaneous short circuit protection is optional
(Note 3) Operational voltage of AC 110V and 50Hz is optional
19
Frame
Type
32AF
100AF
MMS-32H
MMS-63S
MMS-63H
MMS-100S
MMS-110H
Instantaneous type
MMS-32HI
MMS-63HI
MMS-100HI
Breaking capacity
Standard
High breaking
Standard
High breaking
Standard
High breaking
Toggle
Rotary
Rotary
Rotary
Rotary
Rotary
Up to 690V
Up to 690V
Up to 690V
Up to 690V
Up to 690V
Up to 690V
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
690V
690V
1,000V
1,000V
1,000V
1,000V
6kV
6kV
8kV
8kV
8kV
8kV
Cat. A
Cat. A
Cat. A
Cat. A
Cat.A
Cat. A
Handle Type
Number of poles
Rated operational voltage (Ue)
Rated frequency
Rated insulation voltage (Ui)
Rated impulse voltage (Uimp)
Utilization category
63AF
MMS-32S
AC 3
AC 3
AC 3
AC 3
AC3
AC 3
100.000
100,000
50,000
50,000
50,000
50,000
100,000
100,000
25,000
25,000
25,000
25,000
25
25
25
25
25
25
-20 ~ +60C
-20 ~ +60C
-20 ~ +60C
-20 ~ +60C
-20 ~ +60C
-20 ~ +60C
13 x le max.
13 x le max.
13 x le max.
13 x le max.
13 x le max.
13 x le max.
45 x 105 x 54.4
45 x 105 x 60.3
55 x 125 x 112.3
55 x 125 x 112.3
70 x 165 x 138
70 x 165 x 138
320
360
1,000
1,000
2,200
2,200
Overload protection
Phase failure function
Trip indicating function
Test function
Dimension (W x H x D)
Weight (g)
Rated
20
Thermal release
220V
240V
230V
415V
400V
460V
440V
535V
500V
220V
240V
230V
690V
600V
415V
400V
460V
440V
525V
500V
220V
240V
230V
690V
600V
415V
400V
460V
440V
525V
500V
690V
600V
220V
240V
230V
415V
400V
460V
440V
525V
500V
690V
600V
220V
240V
230V
415V
400V
460V
440V
525V
500V
690V
600V
220V
240V
230V
415V
400V
460V
440V
525V
500V
690V
600V
breaking
Rated
Adjustment
capacity
operational
range
(kA)
current (le)
(A)
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
ICU
ICS
0.16
0.1~0.16
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
0.25
0.16~0.25
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
0.4
0.25~0.4
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
0.63
0.4~0.63
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
0.63~1
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
1.6
1~1.6
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
2.5
1.6~2.5
100
100
100
100
100
100
50
38
100
100
100
100
100
100
100
100
2.5~4
100
100
100
100
50
38
15
11
100
100
100
100
100
100
100
100
4~6
100
100
100
100
15
11
10
100
100
100
100
100
100
100
100
5~8
100
100
100
100
15
11
10
100
100
100
100
50
38
50
38
10
6~10
100
100
50
38
15
11
100
100
100
100
50
38
50
38
12
10
38
50
38
13
9~13
100
100
50
38
10
100
100
100
100
50
38
42
32
100 100 50
38
10
38
42
32
17
11~17
50
38
20
15
10
100
100
50
38
20
15
10
100 100 25
19
10
100 100 50
50
50
38
12
100 100 50
38
40
30
25
19
10
38
35
27
12
22
14~22
40
30
15
11
100
100
50
38
20
15
10
50
38
25
19
10
100 100 50
50
50
38
12
100 100 50
38
40
30
25
19
10
50
38
35
27
12
26
18~26
40
30
15
11
100
100
50
38
20
15
10
50
38
25
19
10
100 100 50
50
35
27
12
100 100 50
38
40
30
25
19
10
50
38
35
27
12
32
22~32
30
22
15
11
100
100
50
38
20
15
10
50
38
25
19
10
100 100 50
50
35
27
10
100 100 50
38
40
30
15
11
10
50
38
25
19
12
40
28~40
50
38
25
19
10
100 100 50
50
35
27
10
100 100 50
38
40
30
15
11
50
38
20
15
12
50
34~50
50
38
25
19
10
100 100 50
50
35
27
10
100 100 50
38
40
30
12
50
38
15
11
10
63
45~63
50
38
25
19
10
100 100 50
50
35
27
10
100 100 50
38
40
30
12
50
38
15
11
75
55~75
100 100 50
38
40
30
100 100 75
50
50
38
12
90
70~90
100 100 50
38
40
30
100 100 75
50
50
38
12
100
80~100
100 100 50
38
40
30
100 100 75
50
50
38
12
21
Frame size
[AF]
TE100
TE160
TD100
TD160
TS100
TS160
TS250
TS400
TS630
TS800
100
160
100
160
100
160
250
400
630
800
16~100
300, 400
500, 630
700**, 800
3,4
3,4
2*, 3, 4
1, 2*, 3, 4
2*, 3, 4
2*, 3, 4
2*, 3, 4
2*, 3, 4
2*, 3, 4
2*, 3, 4
Rated operational
AC [V]
690
690
690
240(1P), 690
690
690
690
690
690
690
voltage, Ue
DC [V]
500
500
500
250(1P), 500
500
500
500
500
500
500
750
750
750
750
750
750
750
750
[kV]
220/240V
DC
30(1P)
50(1P)
85
100
200
100
120
200
100
120
200
100
120
200
100
120
200
100
120
200
100
120
200
[kA]
50
85
50
85
85
100
200
380/415V [kA]
37
50
37
50
50
85
150
50
85
150
50
85
150
50
85
150
50
85
150
65
85
150
65
85
150
65
100
150
440/460V [kA]
25
37
25
37
50
70
130
50
70
130
50
70
130
50
70
130
50
70
130
65
85
130
65
85
130
65
100
130
480/500V [kA]
18
25
18
25
30
50
65
30
50
65
42
65
85
42
65
85
42
65
85
42
65
85
42
65
85
42
85
100
660/690V [kA]
10
10
10
15
20
10
15
20
10
15
20
10
20
35
10
20
35
10
20
35
16(1P)
25(1P)
250V [kA]
37
50
37
50
42
65
100
42
65
100
50
85
100
50
85
100
50
85
100
50
85
100
50
85
100
50
85
100
37
50
37
50
42
65
100
42
65
100
50
85
100
50
85
100
50
85
100
50
85
100
50
85
100
50
85
100
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
[kA]
105
187
105
187
187
220
440
105(1P)
105(1P)
187
220
440
220
264
440
220
264
440
220
264
440
220
264
440
220
264
440
220
264
440
380/415V [kA]
77.7
105
77.7
105
105
187
330
105
187
330
105
187
330
105
187
330
105
187
330
143
187
330
143
187
330
143
220
330
440/460V [kA]
52.5
77.7
52.5
77.7
105
154
286
105
154
286
105
154
286
105
154
286
105
154
286
143
187
286
143
187
286
143
220
286
480/500V [kA]
36
52.5
36
52.5
63
105
143
63
105
143
88
143
187
88
143
187
88
143
187
88
143
187
88
143
187
88
187
220
660/690V [kA]
9.2
13.6
9.2
13.6
14
17
14
17
17
30
40
17
30
40
17
30
40
17
40
74
17
40
74
17
40
74
[%lcu]
220/240V
Category of utilization
ATU
MTU ***
LSI
ETS ***
LSI
ETM ***
Earth-fault protection, lg
Ammeter
Communication
Isolation behaviour
Trip unit (release)
Thermal-Magnetic
fixed-thermal, fixed-magnetic
FTU
adjustable-thermal, fixed-magnetic
adjustable-thermal, adjustable-magnetic
magnetic only
*****
FMU
Electronic
Option
Connection
fixed
front-connection
*****
*****
*****
rear-connection
plug-in
front-connection
Mechanical life
rear-connection
[operations]
25000
25000
25000
25000
25000
25000
25000
20000
20000
10000
[operations]
10000
10000
10000
10000
10000
10000
10000
6000
6000
3000
Basic dimensions, W x H x D
1-pole [mm]
35 x 140 x 86
(front connection)
3-pole [mm]
76 x 130 x 82
76 x 130 x 82
90 x 140 x 86
90 x 140 x 86
105 x160 x 86
105 x 160 x 86
105 x 160 x 86
4-pole [mm]
101 x 130 x 82
101 x 130 x 82
120 x 140 x 86
120 x 140 x 86
140 x 160 x 86
140 x 160 x 86
140 x 160 x 86
Weight
1-pole [kg]
0.57
(front connection)
3-pole [kg]
1.05
1.05
1.5
1.5
5.4
5.4
15.1
4-pole [kg]
Reference standard
(Note) applicable or available
** - FLA = 566 A, LRA = 4495 A
22
1.35
1.35
1.8
1.8
2.6
2.6
2.6
7.2
7.2
19.6
IEC60947-2
IEC60947-2
IEC60947-2
IE60947-2
IEC60947-2
IEC60947-2
IEC60947-2
IEC60947-2
IEC60947-2
IEC60947-2
1. The breakers with electronic trip units are available only at 3-pole version. (Only for AC supply)
The trip unit ATU is available from 125A
Amb. Temp.
TD160
TS250
TS630
TS800
TD160
TS250
TS630
TS800
-5C
122.5%
122.5%
110.0%
110.0%
122.0%
122.0%
122.2%
112.2%
0C
120.0%
120.0%
109.0%
109.0%
120.0%
120.0%
112.0%
112.0%
10C
115.0%
115.0%
107.0%
107.0%
116.0%
116.0%
110.0%
110.0%
20C
110.0%
110.0%
105.0%
105.0%
112.0%
112.0%
108.0%
108.0%
25C
107.5%
107.5%
104.0%
104.0%
110.0%
110.0%
107.0%
107.0%
30C
105.0%
105.0%
103.0%
103.0%
108.0%
108.0%
106.0%
106.0%
35C
102.5%
102.5%
101.5%
101.5%
106.0%
106.0%
104.5%
104.5%
40C
100.0%
100.0%
100.0%
100.0%
104.0%
104.0%
103.0%
103.0%
45C
97.5%
97.5%
98.5%
98.5%
102.0%
102.0%
101.5%
101.5%
50C
95.0%
95.0%
97.0%
97.0%
100.0%
100.0%
100.0%
100.0%
23
Electrical Characteristics
Overview
Classification
TS1000
TS1250
TS1600
TS1000
TS1250
TS1600
1000
1250
1600
3, 4
3, 4
3, 4
-5~40C
800, 1000
1250
1600
50C
800, 1000
1250
1560
65C
800, 1000
1240
1420
Type
Ampere frame
Pole
Rated current, (A)
In
Ui
Uimp
Ue
1000
1000
1000
690
690
690
AC50/60Hz
DC
Rated short-circuit breaking capacity
IEC60947-2
220/240V
Current
protection
55
75
200
55
75
55
75
380/415V
50
70
150
50
70
50
70
440/460V
50
65
130
50
65
50
65
480/500V
40
50
100
40
50
40
50
660/690V
35
45
50
35
45
35
45
Rated service
500V 2P
750V 3P
%Icu
100%
75%
100%
100%
75%
100%
75%
25
3s
12
25
-
50
30
50
50
10000
4000
10000
10000
In/2
6000
4000
5000
5000
In
5000
3000
4000
2000
In/2
4000
3000
3000
2000
In
2000
2000
2000
1000
kA peak
25
Isolation
Category
Mechanical life (operations)
Electrical life
440V
(operations)
690V
Pollution degree
L / S / I / G / Thermal
L / S / I / G / Thermal (Continuous)
S type
P type
P type
Over/Under current
-
Over/Under frequency
Unbalance (Voltage/Current)
Reverse power
Current (R / S / T / N)
3 Phase Voltage/Current
RMS/Vector
Measurement
function
3 Phase Voltage/Current
RMS/Vector
Energy (Positive/Negative)
Energy (Positive/Negative)
Frequency, Demand
Frequency, Demand
Voltage/Current harmonics
(1st~63th)
3 Phase Waveforms
THD, TDD, K-Factor
Fine adjustment
P type
time delay/instantaneous/ground
Digital Output
IDMTL setting
Communication
Self Power
- Power source
works over 25% of
Power supply
P type
: DO (Alarm)
(Ground fault is not available
3DO (Fixed)
3DO (Programmable)
L, S/I, G Alarm
Modbus/RS-485
Profibus-DP
Profibus-DP
Profibus-DP
Self Power
AC/DC 100~250V
AC/DC 100~250V
DC 24~60V
DC 24~60V
DC 24~60V
LED for
trip info.
P type
Modbus/RS-485
AC/DC 100~250V
RTC timer
P type
Available
Available
Available
Available
N type
N type
N type
10 records
256 records
256 records
Dimension (mm)
3-pole
(H x W x D)
4-pole
Weight (kg)
3-pole
13
Fault recording
4-pole
16.8
Event recording
Operating
button
24
P type
AC50/60Hz 1s
(Life cycle)
L / S / I / G / Thermal
Other
protection
(sym)
250V 2P
A type
Externals
DC
N type
Ground fault
Reset button
P type
A type
A type
25
Type
Type and Pole
Rated current, In
30
50
60
100
125
250
S-Type
N-Type
S-Type
H-Type
N-Type
S-Type
N-Type
S-Type
H-Type
N-Type
S-Type
H-Type
2 pole
ABS32c
ABN52c
ABS52c
ABH52c
ABN62c
ABS62c
ABN102c
ABS102c
ABH102c
ABN202c
ABS202c
ABH202c
3 pole
ABS33c
ABN53c
ABS53c
ABH53c
ABN63c
ABS63c
ABN103c
ABS103c
ABH103c
ABN203c
ABS203c
ABH203c
4 pole
ABS34c
ABN54c
ABS54c
ABH54c
ABN64c
ABS64c
ABN104c
ABS104c
ABH104c
ABN204c
ABS204c
ABH204c
(3, 5, 10)
15, 20, 30
Rated operational
AC(V)
690
690
690
690
690
690
690
690
690
690
690
690
voltage, Ue
DC(V)
500
500
500
500
500
500
500
500
500
500
500
500
750
750
750
750
750
750
750
750
750
750
750
750
kV
2.5
2.5
10
2.5
10
10
480/500V
7.5
7.5
10
35
7.5
10
10
25
30
18
26
30
415/460V
14 (10)
14
18
50
14
18
18
37
50
26
37
50
380V
18 (14)
18
22
50
18
22
22
42
50
30
42
50
220/250V
30 (25)
30
35
100
30
35
35
85
100
65
85
100
500V(3P)
10
30
10
10
20
30
10
20
30
AC
DC
250V(2P)
Service breaking capacity (%Icu), Ics
Category of use
Endurance
Mechanical
(Number of operations)
Electrical
10
30
10
10
20
30
10
20
30
100
100
100
100
100
100
100
100
100
100
100
100
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
for 3 pole
Accessories
Electrical auxiliaries
Auxiliary switch
Alarm switch
Shunt trip
Undervoltage trip
External accessories
Dimensions (mm)
W x H x D (3P)
Weight (kg)
2 pole
0.5
0.5
0.5
0.7
0.5
0.5
0.5
0.7
0.7
1.1
1.1
1.1
3 pole
0.7
0.7
0.7
0.7
0.7
0.7
1.2
1.2
1.2
4 pole
0.9
0.9
0.9
1.2
0.9
0.9
0.9
1.2
1.2
1.6
1.6
1.6
(Note) 1.
2.
26
applicable or available
available as a seperate breaker
75 x 130 x 60
75 x 130 x 60
90 x 155 x 60
75 x 130 x 60
75 x 130 x 60
90 x 155 x 60
105 x 165 x 60
Amb. Temp.
-5C
0C
10C
20C
25C
30C
35C
40C
45C
50C
In=15 to 30
111.9%
111.3%
110.0%
108.0%
106.6%
104.9%
102.7%
100.0%
96.8%
93.3%
In=40 to 100
110.2%
109.8%
108.7%
107.0%
105.8%
104.3%
102.4%
100.0%
97.2%
94.0%
In=100 to 225
114.3%
113.2%
110.6%
107.5%
105.8%
104.0%
102.0%
100.0%
97.9%
95.6%
In=250 to 800
110.0%
109.0%
107.0%
105.0%
104.0%
103.0%
101.5%
100.0%
98.5%
97.0%
27
Type
Type and Pole
400
800
1000
1200
N-Type
S-Type
H-Type
L-Type
N-Type
S-Type
L-Type
S-Type
L-Type
2 pole
ABN402c
ABS402c
ABH402c
ABL402c
ABN802c
ABS802c
ABL802c
3 pole
ABN403c
ABS403c
ABH403c
ABL403c
ABN803c
ABS803c
ABL803c
ABS1003b
ABL1003b
ABS1203b
ABS1203bE
ABL1203b
4 pole
ABN404c
ABS404c
ABH404c
ABL404c
ABN804c
ABS804c
ABL804c
ABS1004b
ABL1004b
ABS1204b
ABL1204b
Rated operational
AC(V)
690
690
690
690
690
690
690
600
600
600
600
voltage, Ue
DC(V)
500
500
500
500
500
500
500
750
750
750
750
750
750
750
690
690
690
690
690
kV
voltage, Uimp
L-Type
Rated current, In
S-Type
1000
1200
600
DC
690V
10
14
10
14
480/500V
18
35
50
65
25
45
65
50
75
50
50
75
415/460V
37
50
65
85
37
65
85
65
85
65
65
85
380V
42
65
70
100
45
75
100
65
85
65
65
85
220/250V
50
75
85
125
50
85
125
100
125
100
100
125
500V(3P)
10
20
40
40
10
20
40
250V(2P)
Service breaking capacity (%Icu), Ics
Category of use
10
20
40
40
10
20
40
100
100
100
75
100
100
75
Endurance
Mechanical
2500
2500
2500
2500
2500
(Number of operations)
Electrical
500
500
500
500
500
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
for 3 pole
Accessories
Electrical auxiliaries
Auxiliary switch
Alarm switch
Shunt trip
Undervoltage trip
External accessories
Terminal shield
Insulation barrier
Rear connection
-
Plug-in device
Dimensions (mm)
W x H x D (3P)
Weight (kg)
2 pole
5.2
5.2
5.2
5.2
11
11
11
3 pole
6.2
6.2
6.2
6.2
11.5
11.5
11.5
19.6
19.6
4 pole
7.8
7.8
7.8
7.8
18.2
18.2
18.2
25.7
25.7
25.7
(Note) 1.
2.
28
Mechanical interlock
applicable or available
available as a seperate breaker
Amb. Temp.
-5C
0C
10C
20C
25C
30C
35C
40C
45C
50C
In=15 to 30
111.9%
111.3%
110.0%
108.0%
106.6%
104.9%
102.7%
100.0%
96.8%
93.3%
In=40 to 100
110.2%
109.8%
108.7%
107.0%
105.8%
104.3%
102.4%
100.0%
97.2%
94.0%
In=100 to 225
114.3%
113.2%
110.6%
107.5%
105.8%
104.0%
102.0%
100.0%
97.9%
95.6%
In=250 to 800
110.0%
109.0%
107.0%
105.0%
104.0%
103.0%
101.5%
100.0%
98.5%
97.0%
29
125
250
H-Type
N-Type
S-Type
H-Type
N-Type
S-Type
N-Type
S-Type
H-Type
N-Type
S-Type
EBN52c
EBN102c
EBN202c
3 pole
EBS33c
EBN53c
EBS53c
EBH53c
EBN63c
EBS63c
EBN103c
EBS103c
EBH103c
EBN203c
EBS203c
EBH203c
EBS34c
EBS54c
EBH54c
EBS64c
EBN104c
EBS104c
EBH104c
EBS204c
EBH204c
Overload,
Overload,
Overload,
Overload,
Overload,
Short-circuit and
Short-circuit and
Short-circuit and
Short-circuit and
Short-circuit and
Ground fault
Ground fault
Ground fault
Ground fault
Ground fault
15, 20, 30
60
30, 100/200/500
30, 100/200/500
30, 100/200/500
220/460
220/460
220/460
kV
sec
0.1 sec
0.1 sec
mA
AC(V)
100
voltage, Uimp
60
S-Type
4 pole
50
2 pole
Protective function
Rated current, In
30
30, 100/200/500
30, 100/200/500
30, 100/200/500
30, 100/200/500
220/460
220/460
220/460
220/460
0.1 sec
0.1 sec
0.1 sec
0.1 sec
0.1 sec
50
460V
14
14
18
50
14
18
18
37
50
26
37
415V
14
14
18
50
14
18
18
37
50
26
37
50
220/250V
30
30
35
100
30
35
35
85
100
65
85
100
100
100
100
100
100
100
100
100
100
100
100
Endurance
Mechanical
25000
25000
25000
25000
25000
25000
25000
25000
25000
20000
20000
20000
(Number of operations)
Electrical
10000
10000
10000
10000
10000
10000
10000
10000
10000
5000
5000
5000
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
AC
for 3 pole
Accessories
Electrical auxiliaries
Auxiliary switch
Alarm switch
Shunt trip
Undervoltage trip
External accessories
Insulation barrier
Terminal cover (Long)
Terminal cover (Short)
Rotary handle (Direct)
Rotary handle (Direct, Key lock)
W x H x D (3P)
Weight (kg)
2 pole
0.5
0.5
1.1
3 pole
0.7
0.7
0.7
0.7
0.7
0.7
1.2
1.2
1.2
4 pole
0.9
0.9
1.2
0.9
0.9
1.2
1.2
1.5
1.5
(Note) 1.
2.
30
75 x 130 x 60
75 x 130 x 60
90 x 155 x 60
75 x 130 x 60
75 x 130 x 60
90 x 155 x 60
105 x 165 x 60
applicable or available
available as a seperate breaker
31
400
1200
1600
N-Type
S-Type
H-Type
L-Type
N-Type
S-Type
L-Type
S-Type
S-Type
3 pole
EBN403c
EBS403c
EBH403c
EBL403c
EBN803c
EBS803c
EBL803c
EBS1003b
EBS1203b
4 pole
EBN404c
EBS404c
EBH404c
EBL404c
Type
Type and Pole
Protective function
Rated current, In
mA
AC(V)
800
1000
1200
30, 100/200/500mA
30, 100/200/500mA
100/200/500mA
100/200/500mA
220/460
220/460
220/460
220/460
220/460
220/460
220/460
220/460
220/460
kV
sec
0.1 sec
0.1 sec
0.1 sec
0.1 sec
0.1 sec
0.1 sec
0.1 sec
0.1 sec
0.1 sec
37
50
65
85
37
65
85
85
85
AC
220/250V
Service breaking capacity (%Icu), Ics
Category of use
50
75
85
125
50
85
125
125
125
100
100
100
75
100
100
75
Endurance
Mechanical
40000
40000
40000
40000
2500
2500
2500
2500
2500
(Number of operations)
Electrical
10000
10000
10000
10000
500
500
500
500
500
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
Hydraulic-magnetic release
Shunt trip
Undervoltage trip
Insulation barrier
for 3 pole
Accessories
Electrical auxiliaries
Auxiliary switch
Alarm switch
External accessories
Plug-in kit
140 x 257 x 109
W x H x D (3P)
Weight (kg)
2 pole
3 pole
11.5
11.5
11.5
27.1
27.1
4 pole
8.4
8.4
(Note) 1.
2.
32
Dimensions (mm)
applicable or available
available as a seperate breaker
33
Frame size
Metasol
Type
Ampere frame
(AF)
(In max)
at 40C
AN-08D
AN-10D
AN-13D
AN-16D
AS-20D
630
800
1000
1250
1600
2000
200
400
400
630
630
800
Metasol
AN-06D
AS-25E
AS-32E
AS-40E
2000
2500
3200
4000
4000
2500
3200
4000
4000
630
1000
1250
1600
2000
AS-25E
AS-32E
AS-40E
5000
4000
5000
6300
1000, 1250
5000
4000
5000
6300
1600, 2000
(0.4 ~ 1.0) x In max
400
630
Metasol
AS-50F
630, 800
Metasol
AS-20E
630, 800
1000
1250
1600
2000
800
1000, 1250
2500
3200
4000
4000
5000
4000
5000
(Ui)
1000
1000
1000
1000
(Ue)
690
690
690
690
(Uimp)
12
12
12
12
50/60
50/60
50/60
50/60
Frequency (Hz)
Number of poles (P)
3, 4
3, 4
3, 4
220V/230V/380V/415V
65
3, 4
70
85
100
120
460V/480V/500V
65
70
85
100
120
550V/600V/690V
50
65
85
85
100
100%
100%
100%
100%
100%
220V/230V/380V/415V
143
154
187
220
264
460V/480V/500V
143
154
187
220
264
AC 50/60Hz
550V/600V/690V
105
143
187
187
220
Rated short-time
1 sec
50
65
85
85
100
2 sec
42
55
75
75
90
3 sec
36
50
65
65
85
40
40
40
(Icu)
AC 50/60Hz
Rated service breaking capacity (kA)
(Ics)
... % x Icu
(Icm)
(Icw)
Mechanical
Electrical
Connections **
40
80
80
80
80
Without maintenance
20,000
15,000
10,000
10,000
With maintenance
30,000
20,000
15,000
15,000
Without maintenance
5,000
5,000
2,000
2,000
With maintenance
10,000
10,000
5,000
5,000
Horizontal connection
Draw-out / Fixed
6300
1600, 2000
Vertical connection
Weight (kg)
Draw-out type
(3P/4P)
Front connection
Mixed connection
63/74
70/85
87/103
104/147
145/173
181/223
186/230
(With cradle)
61/72
68/83
85/101
102/145
143/171
179/221
184/228
29/32
33/40
44/50
58/70
78/90
97/117
102/124
34/44
38/47
44/55
63/100
76/94
98/123
103/130
32/42
36/45
42/53
61/98
74/92
96/121
101/128
Cradle only
Fixed type
H
W
Draw-out
3P
type
4P
Fixed type
3P
4P
N, A, P type
N, A, P type
N, A, P type
N, A, P type
Trip relay
Certificate & Approval
Marine classification
34
** : Standard,
Main body
: Option
35
Classification
N type
A type
P type
S type
Externals
Current
L / S / I / G / Thermal
protection
L / S / I / G / Thermal
L / S / I / G / Thermal (Continuous)
P type
P type
Over/Under current
Other
protection
Over/Under frequency
Unbalance (Voltage/Current)
Reverse power
Current (R / S / T / N)
3 Phase Voltage/Current
RMS/Vector
Measurement
function
3 Phase Voltage/Current
RMS/Vector
Energy (Positive/Negative)
Energy (Positive/Negative)
Frequency, Demand
Frequency, Demand
Voltage/Current harmonics
(1st~63th)
3 Phase Waveforms
THD, TDD, K-Factor
Fine adjustment
P type
time delay/instantaneous/ground
Overload protection relays
P type
: DO (Alarm)
(Ground fault is not available
when using Pre trip alarm)
Digital Output
IDMTL setting
Communication
Self Power
- Power source
3DO (Programmable)
L, S/I, G Alarm
load current
Modbus / RS-485
Profibus-DP
Profibus-DP
Profibus-DP
Self Power
AC/DC 100~250V
AC/DC 100~250V
DC 24~60V
DC 24~60V
AC/DC 100~250V
DC 24~60V
LED for
trip info.
P type
RTC timer
P type
Modbus/RS - 485
3DO (Fixed)
Available
Available
Available
Available
N type
N type
N type
10 records
256 records
256 records
Fault recording
Event recording
Operating
button
Reset button
Reset, Menu
P type
A type
A type
www.voltex.co.za
37
VL 06
VL 06...36
Type
VL-06
Rated voltage
08
04
VL-06
Ur (kV)
Ir (A)
Rated frequency
Type
06
VH-06
Rated voltage
400
630
fr (Hz)
13
72
50/60
Ir (A)
Rated frequency
12/20/25/32/40
VH-12
50
12/20/25/32/40
7.2
1250
2000
Isc (kA)
12.5
Ik (kA)
12.5
Ik (kA)
(MVA)
100
160
(MVA)
Ip (kA)
20.8
32.5
Ip (kA)
VH-17
50
12
2500
3150
4000
1250
2000
2500
fr (Hz)
50
Ur (kV)
12/20/25/32
17.5
3150
4000
1250
2000
2500
Isc (kA)
50
50
623
1039
1515
(cycle)
Rated withstand
Ud (kV)
20
Rated withstand
Ud (kV)
20
28
38
voltage
Impulse (1.2 x 50
Up (kV)
60
voltage
Impulse (1.2 x 50
Up (kV)
60
75
95
O-0.3s-CO-15s-CO
28
Closing coil
(V)
Trip coil
(V)
Auxiliary contact
(cycle)
)
Control voltage
O-0.3s-CO-3min-CO
Closing coil
(V)
Trip coil
(V)
Auxiliary contact
4a4b, 10a10b
(sec)
0.04
(sec)
0.04
(sec)
0.06
(sec)
0.06
Type test
Mechanical
M2
Electrical
E2 (List1)
(time)
Electrical
(time)
Lifetime *
30000
P type
Installation
(mm)
C2
Mechanical
(time)
Electrical
(time)
130
(kg)
37
37
(kg)
18, 25, 32
19, 26, 33
Weight
20000
20000
Fixed
Draw-out
CB (E, F, G type)
Applied standards
M2
E2 (List3)
30000
Fixed
Mechanical
Electrical
C2
Mechanical
Draw-out
Weight
Type test
P type
P type
P type
G type**
G type**
(mm)
210
275
210
275
210
CB (H type)
(kg)
230
287
275
290
385
230
287
290
385
230
287
290
Cradle (H type)
(kg)
175
320
320
315
175
320
320
315
175
320
320
Applied standards
* With maintenance
3150
50/60
275
275
IEC 62271-100
* With maintenance
** G type (for MCSG)
VL 06...17
Type
VL-06
Rated voltage
Ur (kV)
Ir (A)
Rated frequency
Rated short-circuit current
20/25
06/13/20
VL-12
20/25
7.2
630
1250
2000
630
VL-17
50/60
20/25
06/13/20
17.5
1250
fr (Hz)
2000
630
Type
VH-20
Rated voltage
1250
2000
25
25
VH-20
Ur (kV)
Ir (A)
Rated frequency
32
12/20/32
VH-20
40
12/20/32
24/25.8
2500
1250
fr (Hz)
2000
3150
1250
2000
Isc (kA)
20/25
Isc (kA)
25
31.5
Ik (kA)
20/25
Ik (kA)
25
31.5
40
(MVA)
(MVA)
1039/1117
1309/1407
1662/1787
Ip (kA)
65
82
104
(cycle)
3
60 (65)
250/310
410/520
Ip (kA)
62.5/65
(cycle)
600/750
Rated withstand
Ud (kV)
20
28 (42)
38
Rated withstand
Ud (kV)
voltage
Impulse (1.2 x 50
Up (kV)
60
75
95
voltage
Impulse (1.2 x 50
Up (kV)
Control voltage
O-0.3s-CO-15s-CO
(V)
Trip coil
(V)
Control voltage
O-0.3s-CO-3min-CO
Closing coil
(V)
Trip coil
(V)
Auxiliary contact
4a4b, 10a10b
(sec)
0.04
(sec)
0.04
(sec)
0.06
(sec)
0.06
Type test
Mechanical
M2
Electrical
E2 (List3)
(time)
Electrical
(time)
Weight
Applied standards
* With maintenance
Lifetime *
30000
P type
Draw-out
P type
Installation
(mm)
150
M2
E2 (List3)
30000
Fixed
Mechanical
Electrical
C2
Mechanical
Type test
150 (210)
(time)
Electrical
(time)
20000
20000
Fixed
CB (H type)
(kg)
100
100
130
115 (120)
115 (120)
130 (140)
115 (120)
115 (120)
130 (140)
Cradle (H type)
(kg)
170
170
180
170 (200)
170 (200)
180 (200)
170 (200)
170 (200)
180 (200)
IEC 62271-100
C2
Mechanical
P type
Draw-out
150 (210)
Weight
Applied standards
40
125
Closing coil
Auxiliary contact
3150
60
38
06/13/20
12
275
210
210 (275)
275
210
210 (275)
275
CB (H type)
(kg)
295
256
256 (273)
318
256
256 (273)
318
Cradle (H type)
(kg)
316
275
257 (284)
316
257
257 (284)
316
IEC 62271-100
* With maintenance
39
VH 06...36
Accessories
Type
VH-36
Rated voltage
25
12/20/32
VH-36
32
Ur (kV)
Ir (A)
Rated frequency
1250
2000
3150
1250
2000
fr (Hz)
12/20/32
VH-36
40
12/20/32
3150
1250
2000
25
31.5
40
Ik (kA)
25
31.5
40
(MVA)
1559
1964
2494
Ip (kA)
65
81.9
104
(cycle)
Rated withstand
Ud (kV)
70 (95)
voltage
Impulse (1.2 x 50
Up (kV)
170
Trip coil
(V)
(sec)
0.06
Mechanical
Keylock
Button padlock
E2 (List3)
C2
Earthing S/W
Position S/W
Keylock
Door interlock
Button padlock
MOC
Button cover
TOC
Mechanical
(time)
20000
Electrical
(time)
20000
Plug interlock
Shutter padlock
P type
Fixed
Draw-out
* With maintenance
Position S/W
M2
Electrical
Applied standards
4a4b, 10a10b
0.04
Weight
O-0.3s-CO-3min-CO
DC 48V, DC 110V, DC 125V, DC 220V, AC 48V, AC 110V, AC 220V
(sec)
Installation
(V)
Lifetime *
Cradle
Button cover
Closing coil
Auxiliary contact
Type test
Main
Isc (kA)
3150
50/60
Dimensions
36
300
CB (H type)
(kg)
400
490
400
490
400
490
Earthing S/W
Cradle (H type)
(kg)
700
750
700
750
700
750
Position S/W
Keylock
Door interlock
Button padlock
MOC
Button cover
TOC
Plug interlock
Shutter padlock
IEC 62271-100
G TYPE
Bushing
Insulation Shutter
For MESG
40
F TYPE
Insulation Shutter
For MESG
H TYPE
Bushing
Metal Insulation Shutter
Closed Compartment structure
Earthing Switch & Interlock
For MCSG
Door Interlock
41
GAUTENG
VOLTEX LS
411 Roan Crescent
Corporate Office Park North,
Midrand
Tel: +27 (11) 314 0620
WESTERN CAPE
BELLCO
362 Victoria Road, Salt River
Tel: +27 (21) 440 7100
KWAZULU NATAL
VOLTEX BRIARDENE
2 Brickworks Way, Briardene
Tel: +27 (31) 573 9200
VOLTEX POLOKWANE
Tel: +27 (15) 297 6177
VOLTEX RANDBURG
Tel: +27 (11) 792 3380
VOLTEX BRAMLEY
Tel: +27 (11) 887 1308/9
VOLTEX CENTURION
Tel: +27 (12) 653 3090
VOLTEX DENVER
Tel: +27 (11) 616 6269
VOLTEX KEMPTON PARK
Tel: +27 (11) 970 3290
VOLTEX NEWCASTLE
Tel: +27 (34) 315 4150
VOLTEX REUVEN
Tel: +27 (11) 434 3800
MPUMALANGA
VOLTEX WITBANK
Tel: +27 (13) 692 8536
VOLTEX LYDENBURG
Tel: +27 (13) 235 4706
VOLTEX NELSPRUIT
Tel: +27 (13) 753 3641/2/3/4
NORTHERN CAPE
VOLTEX KIMBERLEY
Tel: +27 (53) 832 1211
VOLTEX UPINGTON
Tel: +27 (54) 332 6211/1874
KWAZULU NATAL
VOLTEX BALLITO
Tel: +27 (32) 946 3966
VOLTEX BRIARDENE
Tel: +27 (31) 573 9200
VOLTEX DURBAN
Tel: +27 (31) 310 7900
VOLTEX PIETERMARITZBURG
Tel: +27 (33) 342 9773
VOLTEX PINETOWN
Tel: +27 (31) 702 0831
NORTH WEST
VOLTEX KLERKSDORP
Tel: +27 (18) 462 1517/9957
VOLTEX RUSTENBURG
Tel: +27 (14) 597 1311
VOLTEX POTCHEFSTROOM
Tel: +27 (18) 297 5520/1
WESTERN CAPE
VOLTEX BLACKHEATH
Tel: +27 (21) 905 1877
VOLTEX BRACKENFELL
Tel: +27 (21) 982 1404
VOLTEX CAPE TOWN
Tel: +27 (21) 531 2033
LIMPOPO
VOLTEX PHALABORWA
Tel: +27 (15) 781 6409/1
VOLTEX TZANEEN
Tel: +27 (15) 307 1213/4
2012/05
www.voltex.co.za
www.lsis.biz
SAFETY INSTRUCTIONS
For your safety, please read users manual thoroughly before operating.
Contact the nearest authorized service facility for examination, repair, or adjustment.
Please contact qualified service technician when you need maintenance.
Do not disassemble or repair by yourself.
Any maintenance and inspection shall be performed by the personnel having expertise concerned.