With what are SIMATIC WinCC flexible 2008, 2007, 2005 and 2004 compatible?

Entry ID: 22055368

WinCC flexible Version Software


2000 Professional SP4 XP Home SP1 *2) XP Home SP2
*2) *2) *1)

WinCC flexible
2004 2004 SP1 2005 2005 SP1 2007 2008 2008 SP1 2008 SP2 2008 SP3

x x

x x x

x x x x
*4)

x x x
*5)

x x x *6)

x x x *6) x x *6) x x *6) x *6)

XP Home SP3 XP Embedded

XP Embedded SP2 XP Embedded Standard 2009 XP Professional SP1 *1) XP Professional SP2 Microsoft Windows (32-Bit) Vista Business Vista Ultimate
*1) *1) *1)

x x

x x

x x x x x x x x x x x x x x *6) x x x x x x x x x x x x x x x x
*6)

XP Professional SP3 *1) Vista Business SP1


*1) *1)

Vista Ultimate SP1 Windows 7 Embedded Standard Windows 7 Embedded Standard SP1 Windows 7 Professional Windows 7 Professional SP1 Windows 7 Enterprise Windows 7 Enterprise SP1 Windows 7 Ultimate Windows 7 Ultimate SP1 Windows 7 Professional Microsoft Windows (64-Bit) Windows 7 Professional SP1 Windows 7 Enterprise Windows 7 Enterprise SP1 Windows 7 Ultimate Windows 7 Ultimate SP1 V6.0 Microsoft Internet Explorer V6.0 SP1 V7.0 V8.0 V9.0 x x x x x x x x

x x

x x x

x x x x

This entry was updated last time 24th of April 2013. You will find the newest list for download at our Compatibility Tool. http://support.automation.siemens.com/WW/view/en/64847782 Use the upper navigation after starting the Compatibility Tool and click at "Tools" for downloading the lists.

Change date: 29.04.2013

This entry is from the Service1Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use apply (http://www.siemens.com/terms_of_use).

Page: 1/4

With what are SIMATIC WinCC flexible 2008, 2007, 2005 and 2004 compatible?

Entry ID: 22055368

WinCC flexible Version Software


Trend Micro OfficeScan V7.3 Trend Micro OfficeScan V8.0 McAfee Internet Security Suite 2007 Virus Scanner McAfee Internet Security Suite 2008 McAfee Application Control V5.1 Symantec Norton Internet Security 2010 V6.0 SP3 V5.3 SP1 V5.3 SP2 V5.3 SP3 V5.4 V5.4 SP1 Step 7 V5.4 SP2 V5.4 SP3 V5.4 SP4 V5.4 SP5 V5.5 V5.5 SP1 V5.5 SP2 V10.5 Step 7 TIA V11.0 V11.0 SP1 V11.0 SP2 V12.0 V6.0 SP1 V6.0 SP3 V6.0 SP4 V6.2 V6.2 SP2 V6.2 SP3 V7.0 V7.0 SP1 V7.0 SP2 V7.0 SP3 x x x x x x *9) x x x
*8)

WinCC flexible
2004 2004 SP1 2005 2005 SP1 2007 2008 2008 SP1 2008 SP2 2008 SP3

x x x x x x x x x *9) x x x
*3)

x x

ProTool/Pro *15)

x *9) x x *10) x x x x

x *9)

*8)

x x x x x

x x x x x x x

x x

x x x x x x x

x x x x

x x x x

x x x x x

x x x x

x x x

SIMATIC WinCC

x x *12) x x x

*12)

*12)

x x x

x *12) x x x x

x x x x

Change date: 29.04.2013

This entry is from the Service2Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use apply (http://www.siemens.com/terms_of_use).

Page: 2/4

With what are SIMATIC WinCC flexible 2008, 2007, 2005 and 2004 compatible?

Entry ID: 22055368

WinCC flexible Version Software


V11.0 WinCC TIA V11.0 SP1 V11.0 SP2 V12.0 V6.2 (CD 11/2003) V6.2 (CD 11/2003) SP1 V6.3 (Edition 2005) V6.4 (Edition 2006) V7.0 (Edition 2007) SIMATIC NET PCSW V7.1 (Edition 2008) V7.1 (Edition 2008) SP2 V7.1 (Edition 2008) SP3 V7.1 (Edition 2008) SP4 V8.0 (Edition 2010) V8.1 (Edition 2011) SP1 V1.4 SP1 V1.4 SP2 SIMATIC Logon V1.4 SP3 V1.4 SP4 V1.5 V7.1 SP1 PCS 7 V7.1 SP2 V7.1 SP3 V7.1 SP4 V8.0 Upd1 SIMATIC PCS 7 Industry Library SIMATIC iMAP V8.0 V2.0 SP1 V3.0 V3.2 SP1 V4.0 V4.1 SP1 SIMOTION Scout V4.1 SP2 V4.1 SP4 V4.1 SP5 V4.2 SP1 V4.3 SP1 HF1 2007 WinAC MP 2008 2008 Upd4 *14)
*14)

WinCC flexible
2004 2004 SP1 2005 2005 SP1 2007 2008 2008 SP1 2008 SP2 2008 SP3

x x x x x x x x x x x x x x x

x x x

x x x x

x x x x

x x

x x x x x x x

x x x x

x x x x x

x x x x x x *7) x *7)

x x x x x

x *16) x x

x x x
*10)

x
*11)

x x
*11)

x x

x x x

x *13) x

x x x

x x x

x x x x

Change date: 29.04.2013

This entry is from the Service3Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use apply (http://www.siemens.com/terms_of_use).

Page: 3/4

With what are SIMATIC WinCC flexible 2008, 2007, 2005 and 2004 compatible?

Entry ID: 22055368

WinCC flexible Version Software


2005 2005 SP1 2005 SP2 WinAC RTX 2008 2008 SP1 2009 2010 SIMATIC S7 1200
2004 2004 SP1 2005

WinCC flexible
2005 SP1 2007 2008 2008 SP1 2008 SP2 2008 SP3

x x x x x x x x x x x x x 38111886 x x 38111886

*1) Release statement applies also for MUI operating systems. *2) Windows XP Home is released only for WinCC flexible Micro Edition of each of the WinCC flexible versions concerned. *3) Not in integrated operation with STEP 7 to V5.3 + SP1 on operating system Windows XP SP2 and not in combination with products from the SIMATIC NET CD 11/2003 + SP1. Technical background: STEP 7 V5.3 + SP1 is not released for Microsoft Windows XP Pro SP2. STEP 7 V5.3 + SP2 is released for Microsoft Windows XP Pro SP2; integrated operation of WinCC flexible 2004 SP1 with STEP 7 V5.3 SP2 is released in Microsoft Windows XP Pro SP2. For further information, please refer to the links below. http://support.automation.siemens.com/WW/view/de/19985823 *4) Only WinCC flexible 2005 Runtime on platforms released for it: SIMATIC Panel PC 477 SIMATIC Panel PC 677 Microbox PC 420 *5) Only WinCC flexible 2007 Runtime on platforms released for it: SIMATIC Panel PC 477/477B Microbox PC 420/427B Box PC 627B SIMATIC Panel PC 677/677B *6) Only WinCC flexible 2008 Runtime on platforms released for it: SIMATIC Panel PC 477/477B Microbox PC 420/427B Box PC 627B SIMATIC Panel PC 677/677B *7) This PCS 7 version is only released with WinCC flexible 2008 SP2 Upd13. *8) Only permissible if configured panels are not connected to a controller via Ethernet later on; otherwise use STEP7 V5.3 SP3 with WinCC flexible 2005 HF3. *9) If you install WinCC flexible on a computer on which ProTool is already installed, under certain circumstances you can no longer start ProTool from STEP 7. As a remedy, call ProTool once via the Windows Start menu following the installation of WinCC flexible. After that you can once again open ProTool from STEP 7. *10) Only in conjunction with WinCC flexible 2005 HF4. *11) With the Component Merger you cannot create any combined PROFINET components, because the Component Merger does not support CPU components in the PCD format V3.0. It is therefore not possible to create combined components in the V3.0 format. *12) It is imperative that you keep to the specified installation sequence when using WinCC V6.2 or WinCC V6.2 SP2. More information is available at this link: http://support.automation.siemens.com/WW/view/de/30576253 *13) There is no release for operation of WinCC flexible 2008 integrated in the SIMOTION SCOUT V4.1 SP1 interface. Release is made separately in the SIMOTION SCOUT context. *14) Please note that WinAC MP 2008 can only be run in Windows XP. *15) Please note that ProTool/Pro is only released for Windows XP SP2. *16) This PCS 7 version is only released with WinCC flexible 2008 SP3 Upd3.