PROJECT : CLIENT : JOB NO.

: Connection from Diaphragm, Ledger to CMU Wall INPUT DATA


GRAVITY LOAD SERVICE ANCHORAGE FORCE SERVICE DIAPHRAGM SHEAR FORCE 2=Hem-Fir(N), 3=Hem-Fir, 4=Spruce-Pine-Fir) LEDGER GRADE D+L = Fanch = V= 250 420 640 0 2 plf
plf

DATE :

PAGE : DESIGN BY : REVIEW BY :

plf Douglas Fir-Larch, G=0.5 No.1

LEDGER SPECIES ( 0=Douglas Fir-Larch, 1=Douglas Fir-Larch(N),

( 0=Select Structural, 1=No.1 & Btr, 2=No.1, 3=No.2, 4=No.3, 5=Stud, 6=Construction, 7=Standard, 8=Utility) LEDGER SIZE 4 x 8 ( No.1, Douglas Fir-Larch, G=0.5 ) f= ANCHOR BOLT DIAMETER 3/4 in WET SERVICE FACTOR ( Tab 10.3.3, NDS 2001, Page 59 ) CM = TEMPERATURE FACTOR ( Tab 10.3.4, NDS 2001, Page 59 ) Ct = PURLIN ANCHORS SPACING TYPE OF MASONRY ( 1=CMU, 2=BRICK ) THICKNESS OF WALL SPECIAL INSPECTION ( 0=NO, 1=YES ) MASONRY STRENGTH REBAR YIELD STRESS WALL HORIZ. REINF. 1 # f M' = fy = t= S= 36 1 8 0 1.5 60 5 in CMU in No ksi ksi @ 16 in. o. c.

1.0 1.0

DESIGN SUMMARY
4 x 8 LEDGER with 3/4 in DIA. A.B.'s @ 36 in o.c. SIMPSON PLURLIN ANCHOR PAI23 w/ 9-10d x 1 1/2 Nails @ 36 in o.c.

ANALYSIS
THE DIAPHRAGM SHEAR TRANSFERS INTO THE TOP OF THE LEDGER BY NAILS THOUGH PLY WOOD AND THE LEDGER BOLTS WOULD RESIST BOTH THE DIAPHRAGM SHEAR BY PARALLEL TO GRAIN BEARING AND THE GRAVITY LOAD BY PERPENDICULAR TO GRAIN BEARING. LATER FORCES IN THE OTHER DIRECTION WOULD BE RESIST BY SIMPSON PLURLIN ANCHORS. CHECK LEDGER CAPACITY LOAD DURATION FACTOR ( Tab 2.3.2, NDS 2001, Page 9 ) GROUP ACTION FACTOR (Sec 10.3.6, NDS 2001, Page 60) GEOMETRY FACTOR ( Sec 11.5.1, NDS 2001, Page 76 ) (CD)Lat = (CD)D+L = Cg = CD = 1.6 1.0 1.0 1.0 ( All dimensions conform to the specified minimums.) Z^ = Z|| = 880 1640

(for wind/seismic loads) (for gravity loads)

DESIGN VALUE FOR THE BOLT BEARING PERPENDICULAR TO GRAIN (Tab 11E, NDS 2001, Page 85) DESIGN VALUE FOR THE BOLT BEARING PARALLEL TO GRAIN (Tab 11E, NDS 2001, Page 85) THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING PARALLEL TO GRAIN THE ANGLE BETWEEN DIRECTION OF COMBINED LOAD AND DIRECTION OF GRAIN THE MAXIMUM ALLOWABLE BOLT SPACING SHALL BE CALCULATED AS FOLLOWS :

lbf lbf
880 2624 2079 lbf lbf lbf

THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING PERPENDICULAR TO GRAIN Z^' = Z^(CD)D+LCMCtCgCD = Z||' = Z||(CD)LATCMCtCgCD = q = 21.34
o

THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING AT THE ANGLE TO GRAIN Zq' = Z^'Z||' /(Z^'cos2q+Z||'sin2q) =

' Z^ , S 1 = MIN D+L

Zq L) ( D ++
2

'

36.30

in

( Use 36 in )

BASIC DESIGN VALUE FOR SHEAR (Tab 4A, NDS 2001 SUPP, Page 31) THE ALLOWABLE DESIGN VALUE FOR SHEAR DEPTH FROM THE UNLOADED EDGE OF THE LEDGER TO THE CENTER OF THE BOLT THE ALLOWABLE DESIGN SHEAR IS GIVEN BY NDS 2001 Eq. 3.4-6, Page 17, AS
' V =

Fv = Fv' =

180 3.63

psi
180

Fv(CD)D+LCMCt =

psi

de =

in

2 ' de F v bd 3 d

761

lbf

>

(D+L)S

756

lbf

[Satisfactory]

DESIGN PURLIN ANCHORS SELECT SIMPSON PAI23 w/ 9-10d x 1 1/2 Nails @ 36 in o.c. DESIGN FORCE FOR STEEL ANCHOR (UBC97,SEC 1633.2.8.1, ITEM 4) : DESIGN FORCE FOR WOOD MEMBER (UBC97SEC. 1633.2.8.1, ITEM 5) : 1.4FanchS = 0.85FanchS = 1764 1071 lbf lbf < < 1880 1128 lbf, allowable lbf, allowable

[Satisfactory]

CHECK WALL CAPACITY TO SPAN LATERALLY S SPACING ALLOWABLE MASONRY STRESS FACTOR : Allowable reinf. stress Allowable stress Steel elasticity modulus Effective width The tensile stress in reinforcement is
2

cont'd = 0.667 Modular ratio Wall reinf. area Tension reinf. ratio The neutral axis depth factor The lever-arm factor
2

SF 32000 330 1350 29000 12 psi psi ksi ksi in

Fs Fb=(SF)(0.33fm') Em Es bw

= = = = =

n As r k j

= = = = =

21.48 0.23 0.005 0.36 0.88 in / ft

Masonry elasticity modulus

The compressive stress in the extreme fiber is < Fs

F S f s == anch 8 A s jd

6938

psi

[Satisfactory]

F S f b == anch 2 4b w jk d

185

psi

<

Fb

[Satisfactory]

Techincal References: 1. "National Design Specification, NDS", 2001 Edition, AF&AP, AWC, 2001. 2. Alan Williams: "Structuiral Engineering Reference Manual", Professional Publications, Inc, 2001.

PROJECT : CLIENT : JOB NO. : Connection from Diaphragm, Ledger to CMU Wall INPUT DATA
GRAVITY LOAD SERVICE ANCHORAGE FORCE SERVICE DIAPHRAGM SHEAR FORCE 1=Southern Pine with 5"-6" Wide) LEDGER GRADE D+L = Fanch = V= 250 420 640 0 2 plf
plf

DATE :

PAGE : DESIGN BY : REVIEW BY :

plf Southern Pine


Non-Dense Select Structural

LEDGER SPECIES ( 0=Southern Pine with 2"-4" Wide,

( 0=Dense Select Structural, 1=Select Structural, 2=Non-Dense Select Structural, 3=No.1 Dense, 4=No.1, 5=No.1 Non-Dense, 6=No.2 Dense, 7=No.2, 8=No.2 Non-Dense)

LEDGER SIZE

10

( Non-Dense Select Structural, Southern Pine ) f= ANCHOR BOLT DIAMETER 3/4 in WET SERVICE FACTOR ( Tab 10.3.3, NDS 2001, Page 59 ) CM = TEMPERATURE FACTOR ( Tab 10.3.4, NDS 2001, Page 59 ) Ct = PURLIN ANCHORS SPACING TYPE OF MASONRY ( 1=CMU, 2=BRICK ) THICKNESS OF WALL SPECIAL INSPECTION ( 0=NO, 1=YES ) MASONRY STRENGTH REBAR YIELD STRESS WALL HORIZ. REINF. 1 # f M' = fy = t= S= 36 1 8 0 1.5 60 5 in CMU in No ksi ksi @ 16 in. o. c. 1.0 1.0

DESIGN SUMMARY
4 x 10 LEDGER with 3/4 in DIA. A.B.'s @ 37 in o.c. SIMPSON PLURLIN ANCHOR PAI23 w/ 9-10d x 1 1/2 Nails @ 36 in o.c.

ANALYSIS
THE DIAPHRAGM SHEAR TRANSFERS INTO THE TOP OF THE LEDGER BY NAILS THOUGH PLY WOOD AND THE LEDGER BOLTS WOULD RESIST BOTH THE DIAPHRAGM SHEAR BY PARALLEL TO GRAIN BEARING AND THE GRAVITY LOAD BY PERPENDICULAR TO GRAIN BEARING. LATER FORCES IN THE OTHER DIRECTION WOULD BE RESIST BY SIMPSON PLURLIN ANCHORS. CHECK LEDGER CAPACITY LOAD DURATION FACTOR ( Tab 2.3.2, NDS 2001, Page 9 ) GROUP ACTION FACTOR (Sec 10.3.6, NDS 2001, Page 60) GEOMETRY FACTOR ( Sec 11.5.1, NDS 2001, Page 76 ) (CD)Lat = (CD)D+L = Cg = CD = 1.6 1.0 1.0 1.0 ( All dimensions conform to the specified minimums.) Z^ = Z|| = 950 1680

(for wind/seismic loads) (for gravity loads)

DESIGN VALUE FOR THE BOLT BEARING PERPENDICULAR TO GRAIN (Tab 11E, NDS 2001, Page 85) DESIGN VALUE FOR THE BOLT BEARING PARALLEL TO GRAIN (Tab 11E, NDS 2001, Page 85) THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING PARALLEL TO GRAIN THE ANGLE BETWEEN DIRECTION OF COMBINED LOAD AND DIRECTION OF GRAIN THE MAXIMUM ALLOWABLE BOLT SPACING SHALL BE CALCULATED AS FOLLOWS :

lbf lbf
950 2688 2164 lbf lbf lbf

THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING PERPENDICULAR TO GRAIN Z^' = Z^(CD)D+LCMCtCgCD = Z||' = Z||(CD)LATCMCtCgCD = q = 21.34
o

THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING AT THE ANGLE TO GRAIN Zq' = Z^'Z||' /(Z^'cos2q+Z||'sin2q) =

' Z^ , S 1 = MIN D+L

Zq L) ( D ++
2

'

37.79

in

( Use 37 in )

BASIC DESIGN VALUE FOR SHEAR (Tab 4B, NDS 2001 SUPP, Page 37) THE ALLOWABLE DESIGN VALUE FOR SHEAR DEPTH FROM THE UNLOADED EDGE OF THE LEDGER TO THE CENTER OF THE BOLT THE ALLOWABLE DESIGN SHEAR IS GIVEN BY NDS 2001 Eq. 3.4-6, Page 17, AS
' V =

Fv = Fv' =

175 4.63

psi
175

Fv(CD)D+LCMCt =

psi

de =

in

2 ' de F v bd 3 d

944

lbf

>

(D+L)S

787

lbf

[Satisfactory]

DESIGN PURLIN ANCHORS SELECT SIMPSON PAI23 w/ 9-10d x 1 1/2 Nails @ 36 in o.c. DESIGN FORCE FOR STEEL ANCHOR (UBC97,SEC 1633.2.8.1, ITEM 4) : DESIGN FORCE FOR WOOD MEMBER (UBC97SEC. 1633.2.8.1, ITEM 5) : 1.4FanchS = 0.85FanchS = 1764 1071 lbf lbf < < 1880 1128 lbf, allowable lbf, allowable

[Satisfactory]

CHECK WALL CAPACITY TO SPAN LATERALLY S SPACING ALLOWABLE MASONRY STRESS FACTOR : Allowable reinf. stress Allowable stress Steel elasticity modulus Effective width The tensile stress in reinforcement is
2

cont'd = 0.667 Modular ratio Wall reinf. area Tension reinf. ratio The neutral axis depth factor The lever-arm factor
2

SF 32000 330 1350 29000 12 psi psi ksi ksi in

Fs Fb=(SF)(0.33fm') Em Es bw

= = = = =

n As r k j

= = = = =

21.48 0.23 0.005 0.36 0.88 in / ft

Masonry elasticity modulus

The compressive stress in the extreme fiber is < Fs

F S f s == anch 8 A s jd

6938

psi

[Satisfactory]

F S f b == anch 2 4b w jk d

185

psi

<

Fb

[Satisfactory]

Techincal References: 1. "National Design Specification, NDS", 2001 Edition, AF&AP, AWC, 2001. 2. Alan Williams: "Structuiral Engineering Reference Manual", Professional Publications, Inc, 2001.