Datele climatice caracteristice localitii n care este amplasat cldirea

Bucuresti zona climatica II

Altitudine
92

ian.
-2.4

feb.
-0.1

mart.
4.8

apr.
11.1

mai
16.7

Lunile
iunie iulie
20.2
22.0

aug.
21.2

sept.
16.9

oct.
10.1

nov.
5.2

dec.
0.2

BUCURESTI
Luna
ITS

I
76.7

II
106.9

III
103.5

IV
94.8

V
91.6

VI
96.8

VII
94.9

VIII
138.1

IX
136.8

X
125.7

XI
73.3

XII
68.9

ITS-V

59.3

87.3

91.4

91.6

86.0

92.8

89.9

123.8

119.1

104.1

57.4

53.0

ITV

30.9

53.9

65.9

76.0

74.9

79.6

72.2

78.0

84.6

66.0

33.0

27.3

ITN-V

14.9

28.0

38.9

52.8

70.4

78.2

71.1

75.8

60.1

36.3

16.5

12.3

ITN

13.6

20.7

30.0

39.6

65.9

76.9

70.1

73.7

51.2

25.2

15.3

11.7

ITN-E

14.9

28.0

38.9

52.8

70.4

78.2

71.1

75.8

60.1

36.3

16.5

12.3

ITE

30.9

53.9

65.9

76.0

74.9

79.6

72.2

78.0

84.6

66.0

33.0

27.3

ITS-E

59.3

87.3

91.4

91.6

86.0

92.8

89.9

123.8

119.1

104.1

57.4

53.0

233.5

200.8

233.2

175.5

114.2

54.2

41.3

ITOriz

49.6

85.0

124.8

167.2

205.6

ID-Vert

13.6

20.7

30.0

39.6

46.9

50.3

48.2

45.0

35.6

25.2

15.3

11.7

ID-Oriz

27.1

41.4

60.0

79.2

93.9

100.7

96.3

90.1

71.1

50.4

30.6

23.5

Temperaturi subsol 2 - neincalzit, fara instalatii termice


Planseu peste planseu izolat termic R = 1,50 mpK/W
Luna
I
II
III
IV
V
VI
Bloc
10.34
10.13
11.45
13.03
14.91 16.25

VII
17.26

VIII
17.59

IX
16.74

X
15.06

XI
13.39

XII
11.55

Temperatura camerei troliului - sp. neincalzit, fara instalatii termice, Rpe3 = 1.238 mpK/W
Luna
I
II
III
IV
V
VI
VII
VIII
IX
Bloc
15.84
16.19
17.03
18.13
19.09 19.71 20.06 19.95
19.23

X
18.18

XI
17.21

XII
16.32

Temperatura interioara rezultanta medie a zonei principale a cladirii - ti med

timed

t i , jV j
j 1
n

V j
j 1

ta
10.5

timed

t i , jV j
j 1
n

V j
j 1

hol
birouri
casa scarii
gr. sanitare
windfang
c. termica
arhiva
server
sp. tehnic
put lift
sala mese

ti
[gr. C]
20
20
20
15
12
15
20
10
18
20
20

S sbs S parter
S1
S 2-4 S 5-6
[mp]
[mp]
[mp]
[mp]
[mp]
32.25
68.75
30.35 30.35 30.85
92.9
147.5
252.35 257.8 358.6
21
21.55
21.15 21.15 21.15
15.05
19
21.7
19
19
8
47.55
68.9
11.1
4.3
4.3
4.3
4.3
5.76
ti,j*Vj = 186011.57
Vj
= 9503.60

S7
[mp]
20.75
80

H nivel
[m]
3.31
3.31
3.31
3.31
3.31
3.31
3.31
3.31
3.31
28.16
2.86

Vj
[mc]
940.37
6564.06
560.88
498.98
26.48
157.39
228.06
36.74
99.63
162.20
228.8

tij*Vj
18807.42
131281.2
11217.59
7484.74
317.76
2360.86
4561.18
367.41
1793.36
3244.03
4576

ti med = 19.57

CALCULUL Ngz - metoda analitica - cap. 3.1.1 / NP 048, la care se adauga corectia datorata incalzirii cu intermitenta (c

luna
tiR
teR
tiR - teR

Dz(k)

august
septembr. octombr. noiembr. decembr.
ian.
febr.
16.34
16.34
16.34
16.34
16.34
16.34
16.34
24.67
20.37
14.05
7.63
2.94
0.85
3.74
-8.33
-4.03
2.29
8.71
13.4
15.49
12.6
Z(0)
Z(1)

[
tiR > teR
Dz(0)=0
Dz(1)=31 Dz(2)=30 Dz(3)=31 Dz(4) =31 Dz(5)=28

Ngz(k)

70.99

261.3

Dz1 = 0.5* tiR - teR (1)


teR (0) - teR(1)

*[ Z(0) + Z(1)]

DzL = 0.5* tiR - teR (L)


teR (L+1) - teR(L)

*[ Z(L) + Z(L+1)] =

415.4

480.19

352.8

10.98

tiR (1)>teR (1) = >

8.61

tiR (L)>teR (L) = >

DzL<0.5*Z(1)
DzL<0.5*Z(L)

=>
=>

k=L+1

Dz =

Dz(k) =Dz(0) + Dz(1) +..Dz(L) + Dz(L+1) = 212


k=0

Ngz (k) = Dz(k)* [ tiR - teR(k)], in care k=1,.., L


Ngz (k) =
1858.26
NUMARUL CORECTAT DE GRADE-ZILE "Ngz" - pt incalzirea cu intermitenta
Ngz = [(k)*Ngz(k)]

in care: (k)

f + a(k)*0(k) + G(k)*(k)
P
0(k) =

Qo
Q inc(k)

f = 8

Q o = 60.8+219.3 = 280.1 kW = 280100 W


Q inc(k) = ( SE/Rmed + 0.33*B1*na*V)*C*[tiR - teR(k)]

luna
SE/ R med
B1
na
V
C
tiR
teR
Q inc(k)
Qo

august
septembr. octombr. noiembr. decembr.
3,361.81
3,361.81 3,361.81
3,361.81 3,361.81
1.182
1.182
1.182
1.182
1.182
0.435
0.435
0.435
0.435
0.435
9944.3
9944.3
9944.3
9944.3
9944.3
0.892
0.892
0.892
0.892
0.892
16.34
16.34
16.34
16.34
16.34
24.67
20.37
14.05
7.63
2.94
-37516.78 -18150.37
280100
280100

10313.74
280100

39228.23 60351.12
280100
280100

ian.
febr.
3,361.81 3,361.81
1.182
1.182
0.435
0.435
9944.3
9944.3
0.892
0.892
16.34
16.34
0.85
3.74
69764.10 56748.07
280100
280100

o (k)

-7.47

-15.43

27.16

7.14

4.64

4.01

Calculul Mc - capacitatea termica a elementelor de constructie interioare


(pt b.a., bca, caramida 0.1m, pt mat. termoizolante 0.05m )
Elem. comp. material
Suprafata

c
S*(**c)
al anvelopei
[mp]
[kg/mc]
[m]
[J/kg K]
PE1
Tencuiala int.
1143.5
1600
0.01
840 89235881
Zidarie BCA
825
0.09
870
Tencuiala ext.
1700
0.02
840
PE2
Tencuiala int.
69.84
1600
0.01
840 14667381
Diafragma b. a.
2600
0.09
840
Hidroizolatie
600
0.001
1460
Polistiren extr.
20
0.025
1460
Caramida
1800
0.125
870
PE2'
Tencuiala int.
165.76
1600
0.01
840 34809600
Diafragma b. a.
2600
0.09
840
Hidroizolatie
600
0.001
1460
Polistiren extr.
20
0.025
1460
Caramida
1800
0.125
870
Pamant
PE3
Tencuiala int.
29.05
1600
0.01
840
390432
Zidarie BCA
825
0.1
870
Tencuiala int.
1600
0.01
840
PE4
Tencuiala int.
88.94
1600
0.01
840 18677400
Diafragma b.a.
2600
0.09
840
Polistiren exp
20
0.05
1460
Tencuiala ext.
1700
0.02
840
F1 - ferestre Sticla - 70%
180.8
2500
0.012
840
4556160
R =0.55
Rama Al. - 30%
77.48
2600
0.05
480
4834752
F2 - ferestre Sticla - 70%
453.91
2500
0.012
840 11438532
cortina, R=0.9 Rama Al. - 30%
194.53
2600
0.05
480 12138672
Placa
Finisaj - gresie
327.06
2400
0.01
920 62717026
peste subsol 2 Sapa - ciment
1800
0.04
840
Placa b. a.
2600
0.05
840
Polistiren exp.
20
0.05
1460
Tencuiala int.
1600
0.015
840
Terasa
Gresie
347.29
2400
0.015
920 71472282
circulabila
Sapa - ciment
1800
0.04
840
Hidroiz. Bitum.
600
0.001
1460
Termoiz. BCA
600
0.15
840
Bariera vapori
600
0.002
1460
Beton de panta
1800
0.12
840
Placa b. a.
2600
0.085
840
Tencuiala int.
1600
0.015
840
Terasa
Pietris
13.4
1800
0.04
840
2757720
necirculabila Sapa - ciment
1800
0.04
840
Hidroiz. Bitum.
600
0.001
1460
Termoiz. BCA
600
0.15
840
Bariera vapori
600
0.002
1460
Beton de panta
1800
0.12
840
Placa b. a.
2600
0.085
840

4.94

Tencuiala int.
A1 (vezi plan) Gresie
Sapa - ciment
Hidroiz. Bitum.
Placa b. a.
Polistiren
Tencuiala int.
A2 (vezi plan) Finisaj-mocheta
Sapa - ciment
Placa b. a.
Polistiren exp.
Tencuiala ext.
A3 (vezi plan) Finisaj-mocheta
Sapa - ciment
Placa b. a.
Polistiren exp.
Tencuiala ext.
Usi ext.
Foaie de tabla
metalice
Int. - poliuretan
(subsol)
Foaie de tabla
Mc

35.6

58.54

4.7

5.04

1600
2400
1800
600
2600
20
1600
1600
1800
2600
20
1600
1600
1800
2600
20
1600
2600
30
2600

0.015
0.01
0.04
0.01
0.035
0.05
0.015
0.005
0.045
0.05
0.05
0.02
0.005
0.045
0.05
0.05
0.02
0.0015
0.035
0.0015

343160671

Tc

1
3600

Mc
SE/Rmed+ 0.33*B1*na*Vinc

Tc

1
3600

343160671
3361.81 +

18.88

343160671

1687.31

constanta de timp a constructiei

3600

E = exp[-(24 - f)/Tc] = exp(-(24-8)/18.88)=


0.428502963

3490936

11059377

887924

26596.08

343160671

Mc = [Sm* pm*pm*cpm]

Tc

840
920
840
1460
840
1460
840
1460
840
840
1460
840
1460
840
840
1460
840
480
1460
480

5049.12 67964.451 18.87901

0.43

atorata incalzirii cu intermitenta (cap. 3.1.3 / NP 048)

martie
aprilie
mai
16.34
16.34
16.34
8.76
14.92
19.99
7.58
1.42
-3.65

Z(L)
Z(L+1)
]
Dz(6)=31 Dz(7)=30 Dz(8)=0
234.98

iunie
16.34
23.33
-6.99

iulie
16.34
24.73
-8.39

42.6

Dz1 = 31

(oct.)

DzL = 30

(aprilie)

Dz0 = 0
Dz(L+1) = 0

NGZ corectat pentru incalzirea cu intermitenta


TiR (k) =

tiR - teR (k)


ti med - teR (k)

P = 24
(k)

tiG - teR (k)


ti med - teR (k)

na*V)*C*[tiR - teR(k)]

martie
aprilie
mai
iunie
3,361.81 3,361.81 3,361.81 3,361.81
1.182
1.182
1.182
1.182
0.435
0.435
0.435
0.435
9944.3
9944.3
9944.3
9944.3
0.892
0.892
0.892
0.892
16.34
16.34
16.34
16.34
8.76
14.92
19.99
23.33
34138.92
280100

iulie
3,361.81
1.182
0.435
9944.3
0.892
16.34
24.73

luna
tiR
teR
ti med
ti - teR
TiR(k)
tiG
(k)
o (k)
6395.42 -16438.93 -31481.67 -37787.01 276939.59 E
280100
280100
280100
280100
termen B

august
16.34
24.67
19.57
-5.1
1.633
12
2.48
-7.45
0.43
0.411

8.20

43.80

-17.04

-8.90

-7.41

termen 1
Tc
a(k)
G(k)
(k)
Ngz(k)

22.58
18.88
0.000
-

NGZ = [ (k) * Ngz(k)] =

Determinarea a(k) si G(k) prin verificarea inegalitatii :


teR(k) +[ti - teR(K)]*

teR(k)+[ti - teR(k)] ]*
[

Determinarea coeficientului de corectie a necesarului de c


(k)

f + a(k) * o (k) +

tru incalzirea cu intermitenta

tiG = 12 C

septembr.
16.34
20.37
19.57
-0.8
5.038
12
10.46
-15.28
0.43
0.427

octombr.
16.34
14.05
19.57
5.52
0.415
12
-0.37
27.64
0.43
0.452

noiembr.
16.34
7.63
19.57
11.94
0.729
12
0.37
7.16
0.43
0.483

decembr.
16.34
2.94
19.57
16.63
0.806
12
0.54
4.64
0.43
0.507

ian.
16.34
0.85
19.57
18.72
0.827
12
0.60
4.02
0.43
0.519

febr.
16.34
3.74
19.57
15.83
0.796
12
0.52
4.95
0.43
0.503

martie
16.34
8.76
19.57
10.81
0.701
12
0.30
8.25
0.43
0.477

aprilie
16.34
14.92
19.57
4.65
0.305
12
-0.63
43.80
0.43
0.449

20.03
18.88
0.000
-

16.55
18.88
0.963
0
1.442
70.99

13.39
18.88
2.182
0
0.984
261.30

11.38
18.88
2.903
1.631
0.932
415.40

10.56
18.88
3.026
3.191
0.919
480.19

11.70
18.88
2.845
0.874
0.939
352.80

13.92
18.88
1.958
0
1.007
234.98

17.01
18.88
0.822
0
1.834
42.60

1833.97

si G(k) prin verificarea inegalitatii :

+[ti - teR(K)]*

E
1+(E-1)/o(k) *TiR(k)

> tiG

Inegalitatea se verifica
pt lunile oct., nov., martie, aprilie, deci: a(k) = -Tc*ln{1+(E-1)/ o (k)*TiR(k)}
G(k) = 0

*[

termen B

termen 1

]
]

Pt lunile dec. , ian., feb.


inegalitatea nu se verifica, deci:

a(k) = -Tc*ln{[1- o (k)*TiR(k)]/[ (k) - o (k)*


G(k) = p - f + Tc*ln[ (k)] - a(k)

cientului de corectie a necesarului de caldura (k)


(k)

f + a(k) * o (k) + G(k)* (k)


P

f =
P =

88
24

mai
16.34
19.99
19.57
-0.42
8.690
12
19.02
-16.95
0.43
0.428

iunie
16.34
23.33
19.57
-3.76
1.859
12
3.01
-8.87
0.43
0.416

iulie
16.34
24.73
19.57
-5.16
1.626
12
2.47
-7.39
0.43
0.411

19.81
18.88

21.77
18.88

22.61
18.88

{1+(E-1)/ o (k)*TiR(k)}

[1- o (k)*TiR(k)]/[ (k) - o (k)*TiR(k)]}

+ Tc*ln[ (k)] - a(k)

TEMPERATURA EXT. ECHIVALENTA CARACTERISTICA PERETELUI EXT.TRANSPARENT


=0.3, R1= 0,55 - ferestre termoizolante, rama de Al. , R2 =0,9 - perete cortina
csn = 0,55

t EF

TEMPERATURA EXT. ECHIVALENTA

n RFn csn I Tn 1 csn I dif n t e

t E pe j

NORD

NORD

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

R1
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3

R2
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

csn
-

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala N I dif. Vert. t e


73.7
45
51.2
35.6
25.2
25.2
15.3
15.3
11.7
11.7
13.6
13.6
20.7
20.7
30
30
39.6
39.6
65.9
46.9
76.9
50.3
70.1
48.2

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I tot N-V I dif. Vert. t e


75.8
45
60.1
35.6
36.3
25.2
16.5
15.3
12.3
11.7
14.9
13.6
28
20.7
38.9
30
52.8
39.6
70.4
46.9
78.2
50.3
71.1
48.2

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

tFn (R1) tFn (R2)


31.23
24.19
14.96
7.72
2.13
-0.16
3.32
9.75
17.83
26.16
30.91
31.94
-

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

tFn (R1) tFn (R2)


31.42
37.92
25.00
30.15
15.97
19.25
7.83
9.51
2.18
3.45
-0.04
1.47
3.98
6.57
10.56
14.22
19.03
23.95
26.57
32.85
31.03
37.92
32.03
38.41

N-V

abs
august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

N-V

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

R1
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3

R2
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

csn
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9

SUD

abs
august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

SUD

R1

R2

csn

I totala S

I dif. Vert. t e

tFn (R1)

tFn (R2)

abs
cs I T 1
e

abs

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

138.1
136.8
125.7
73.3
68.9
76.7
106.9
103.5
94.8
91.6
96.8
94.9

45
35.6
25.2
15.3
11.7
13.6
20.7
30
39.6
46.9
50.3
48.2

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

37.07
31.96
24.08
12.99
7.32
5.57
11.14
16.42
22.84
28.50
32.72
34.19

SUD-VEST

0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

SUD-VEST

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

R1
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3

R2
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

csn
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala SV I dif. Vert. t e


123.8
45
119.1
35.6
104.1
25.2
57.4
15.3
53
11.7
59.3
13.6
87.3
20.7
91.4
30
91.6
39.6
86
46.9
92.8
50.3
89.9
48.2

R1
0.3
0.3
0.3
0.3

R2

0.55
0.55
0.55
0.55

I totala SV I dif. Vert. t e


123.8
45
119.1
35.6
104.1
25.2
57.4
15.3

csn
0.9
0.9
0.9
0.9

abs

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

tFn (R1) tFn (R2)


35.78
45.05
30.35
38.91
22.12
29.32
11.55
15.58
5.88
9.49
3.99
8.06
9.36
15.38
15.32
22.02
22.55
29.71
27.99
35.17
32.36
40.09
33.74
41.21

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

21.2
16.9
10.8
5.2

tFn (R1)
-

TERASA / ZONA JARDINIERE PART


abs
august
0.8
septembrie
0.8
octombrie
0.8
noiembrie
0.8

SUD-EST
august
septembrie
octombrie
noiembrie

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

tFn (R2)
45.05
38.91
29.32
15.58

0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3

0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

53
59.3
87.3
91.4
91.6
86
92.8
89.9

11.7
13.6
20.7
30
39.6
46.9
50.3
48.2

0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

9.49
8.06
15.38
22.02
29.71
35.17
40.09
41.21

decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

EST

EST

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8

R1
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3

R2
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

csn
-

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala E I dif. Vert. t e


78
45
84.6
35.6
66
25.2
33
15.3
27.3
11.7
30.9
13.6
53.9
20.7
65.9
30
76
39.6
74.9
46.9
79.6
50.3
72.2
48.2

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

abs

tFn (R1) tFn (R2)


31.62
27.22
18.66
9.33
3.55
1.41
6.33
13.01
21.14
26.98
31.16
32.13

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

TEMPERATURA EXTERIOARA VIRTUALA t ev - cf. rel. (10), NP 048

Sp

R
t ev

luna
tEpe1 NORD

ej

pe j

tE p

ej

Sp
Sn
tEF
tp
n
RFn
p Rp
t ev =

SE
R

august septembr. octombr. noiembr.


22.63
17.94
11.39
5.56

decembr.
0.48

ian.
-2.08

febr.
0.39

martie
5.51

aprilie
12.23

1+2+3
SE/Rmed

mai
18.05

iunie
21.73

iulie
23.42

Spe1/Rpe1 (N)
tEpe2 NORD
Spe2/Rpe2 (N)
tEpe4 NORD
Spe4/Rpe4 (N)
tEpe1 F.O.
Spe1/Rpe1 (FO)
tEpe2' F.O.
Spe2'/Rpe2' (FO)
tEpe3 F.O.
Spe3/Rpe3 (FO)
tEpe1 N-V
SPE1/RPE1(NV)
tEpe2 N-V
SPE2/RPE2(NV)
tEpe1 SUD
SPE1/RPE2 (S)
tEpe2 SUD
SPE2/RPE2 (S)
tEpe1 S-V
SPE1/RPE1(SV)
tEpe2 S-V
SPE2/RPE2(SV)
tEpe1 EST
SPE1/RPE1 (E)
tEpe2 EST
SPE2/RPE2 (E)
tEFn1 NORD
SFn1/RFn (N)
tEFn1 N-V
SFn1/RFn1 (NV)
tEFn2 N-V
SFn2/RFn2 (NV)
tEFn1 SUD
SFn1/RFn1 (S)
tEFn1 S - V
SFn1/RFn1 (SV)

180.71
22.63
12.36
22.63
74.74
21.20
13.13
21.20
70.71
19.95
26.08
22.66
29.37
22.66
11.44
23.46
293.78
23.46
14.42
23.28
137.80
23.28
18.24
22.69
532.65
22.69
26.00
31.23
130.84
31.42
26.84
37.92
262.31
37.07
84.11
35.78
85.45

180.71
17.94
12.36
17.94
74.74
16.90
13.13
16.90
70.71
19.23
26.08
18.05
29.37
18.05
11.44
19.05
293.78
19.05
14.42
18.82
137.80
18.82
18.24
18.37
532.65
18.37
26.00
24.19
130.84
25.00
26.84
30.15
262.31
31.96
84.11
30.35
85.45

180.71
11.39
12.36
11.39
74.74
10.80
13.13
10.80
70.71
18.18
26.08
11.54
29.37
11.54
11.44
12.69
293.78
12.69
14.42
12.41
137.80
12.41
18.24
11.92
532.65
11.92
26.00
14.96
130.84
15.97
26.84
19.25
262.31
24.08
84.11
22.12
85.45

180.71
5.56
12.36
5.56
74.74
5.20
13.13
5.20
70.71
17.21
26.08
5.58
29.37
5.58
11.44
6.31
293.78
6.31
14.42
6.10
137.80
6.10
18.24
5.79
532.65
5.79
26.00
7.72
130.84
7.83
26.84
9.51
262.31
12.99
84.11
11.55
85.45

180.71
0.48
12.36
0.48
74.74
0.20
13.13
0.20
70.71
16.32
26.08
0.48
29.37
0.48
11.44
1.22
293.78
1.22
14.42
1.01
137.80
1.01
18.24
0.68
532.65
0.68
26.00
2.13
130.84
2.18
26.84
3.45
262.31
7.32
84.11
5.88
85.45

180.71
-2.08
12.36
-2.08
74.74
-2.40
13.13
-2.40
70.71
15.84
26.08
-2.06
29.37
-2.06
11.44
-1.26
293.78
-1.26
14.42
-1.49
137.80
-1.49
18.24
-1.86
532.65
-1.86
26.00
-0.16
130.84
-0.04
26.84
1.47
262.31
5.57
84.11
3.99
85.45

180.71
0.39
12.36
0.39
74.74
-0.10
13.13
-0.10
70.71
16.19
26.08
0.48
29.37
0.48
11.44
1.50
293.78
1.50
14.42
1.25
137.80
1.25
18.24
0.82
532.65
0.82
26.00
3.32
130.84
3.98
26.84
6.57
262.31
11.14
84.11
9.36
85.45

180.71
5.51
12.36
5.51
74.74
4.80
13.13
4.80
70.71
17.03
26.08
5.62
29.37
5.62
11.44
6.46
293.78
6.46
14.42
6.30
137.80
6.30
18.24
5.97
532.65
5.97
26.00
9.75
130.84
10.56
26.84
14.22
262.31
16.42
84.11
15.32
85.45

180.71
12.23
12.36
12.23
74.74
11.30
13.13
11.30
70.71
18.13
26.08
12.40
29.37
12.40
11.44
12.95
293.78
12.95
14.42
12.90
137.80
12.90
18.24
12.70
532.65
12.70
26.00
17.83
130.84
19.03
26.84
23.95
262.31
22.84
84.11
22.55
85.45

180.71
18.05
12.36
18.05
74.74
16.70
13.13
16.70
70.71
19.09
26.08
18.11
29.37
18.11
11.44
18.38
293.78
18.38
14.42
18.31
137.80
18.31
18.24
18.17
532.65
18.17
26.00
26.16
130.84
26.57
26.84
32.85
262.31
28.50
84.11
27.99
85.45

180.71
21.73
12.36
21.73
74.74
20.20
13.13
20.20
70.71
19.71
26.08
21.74
29.37
21.74
11.44
21.99
293.78
21.99
14.42
21.93
137.80
21.93
18.24
21.76
532.65
21.76
26.00
30.91
130.84
31.03
26.84
37.92
262.31
32.72
84.11
32.36
85.45

180.71
23.42
12.36
23.42
74.74
22.00
13.13
22.00
70.71
20.06
26.08
23.43
29.37
23.43
11.44
23.74
293.78
23.74
14.42
23.67
137.80
23.67
18.24
23.44
532.65
23.44
26.00
31.94
130.84
32.03
26.84
38.41
262.31
34.19
84.11
33.74
85.45

tEFn2 S - V
45.05
SFn2/RFn2 (SV) 427.92
tEFn2 S-E
45.05
SFn2/RFn2 (S)
30.250
tEFn1 EST
31.62
SFn1/RFn1 (E)
109.20
tEFn1 F.O.
21.20
SFn1/RFn1 (FO) 33.16
tp terasa
23.22
Sp/Rp terasa
359.51
tE plan parter
23.22
Sp/Rp pl parter
51.76
tE subsol 2
17.59
Sp/Rp subsol 1
180.50
1+2+3
91394.5
SE/R
3,361.81
tev
27.19

38.91
29.32
15.58
9.49
8.06
15.38
22.02
29.71
35.17
40.09
41.21
427.92 427.92
427.92
427.92
427.92
427.92
427.92
427.92
427.92
427.92
427.92
38.91
29.32
15.58
9.49
8.06
15.38
22.02
29.71
35.17
40.09
41.21
30.250 30.250
30.250
30.250
30.250
30.250
30.250
30.250
30.250
30.250
30.250
27.22
18.66
9.33
3.55
1.41
6.33
13.01
21.14
26.98
31.16
32.13
109.20 109.20
109.20
109.20
109.20
109.20
109.20
109.20
109.20
109.20
109.20
16.90
10.80
5.20
0.20
-2.40
-0.10
4.80
11.30
16.70
20.20
22.00
33.16
33.16
33.16
33.16
33.16
33.16
33.16
33.16
33.16
33.16
33.16
20.28
15.76
11.83
8.30
6.71
7.87
13.75
18.08
21.17
22.42
23.69
359.51 359.51
359.51
359.51
359.51
359.51
359.51
359.51
359.51
359.51
359.51
20.28
15.76
11.83
8.30
6.71
7.87
13.75
18.08
21.17
22.42
23.69
51.76
51.76
51.76
51.76
51.76
51.76
51.76
51.76
51.76
51.76
51.76
16.74
15.06
13.39
11.55
10.34
10.13
11.45
13.03
14.91
16.25
17.26
180.50 180.50
180.50
180.50
180.50
180.50
180.50
180.50
180.50
180.50
180.50
76278.4 53787.8 30138.84 14104.96 7477.113 18454.45 36230.52 57357.58 74696.86 86205.31 90551.39
3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81
22.69
16.00
8.97
4.20
2.22
5.49
10.78
17.06
22.22
25.64
26.94

TEMPERATURA EXTERIORA DE REFERINTA - teR, cf. rel (9) din NP 048

t eR

luna
SE/ R med
B1
fta
na
V
tev
te
teR

SE

R 0.33 B1 f ta na V t ev 0.33 na V t e

SE
0.33 B1 na V
R

august septembr. octombr. noiembr. decembr.


ian.
febr.
martie
aprilie
mai
iunie
iulie
3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81
1.182
1.182
1.182
1.182
1.182
1.182
1.182
1.182
1.182
1.182
1.182
1.182
1.107
1.107
1.107
1.107
1.107
1.107
1.107
1.107
1.107
1.107
1.107
1.107
0.435
0.435
0.435
0.435
0.435
0.435
0.435
0.435
0.435
0.435
0.435
0.435
9944.3 9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
27.19
22.69
16
8.97
4.2
2.22
5.49
10.78
17.06
22.22
25.64
26.94
21.20
16.90
10.80
5.20
0.20
-2.40
-0.10
4.80
11.30
16.70
20.20
22.00
24.67
20.37
14.05
7.63
2.94
0.85
3.74
8.76
14.92
19.99
23.33
24.73

ATURA EXT. ECHIVALENTA CARACTERISTICA PERETELUI EXT.OPAC

abs
cs I T 1 cs
e
j

17
17
17
17
17
17
17
17
17
17
17
17

abs/ e csn
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala N I dif. Vert. t e


73.7
45
51.2
35.6
25.2
25.2
15.3
15.3
11.7
11.7
13.6
13.6
20.7
20.7
30
30
39.6
39.6
65.9
46.9
76.9
50.3
70.1
48.2

17
17
17
17
17
17
17
17
17
17
17
17

abs/ e csn
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I tot N-V I dif. Vert. t e


75.8
45
60.1
35.6
36.3
25.2
16.5
15.3
12.3
11.7
14.9
13.6
28
20.7
38.9
30
52.8
39.6
70.4
46.9
78.2
50.3
71.1
48.2

I t
j

abs/ e

dif

csn

I totala S

I dif. Vert. t e

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

tEpe j,n
22.63
17.94
11.39
5.56
0.48
-2.08
0.39
5.51
12.23
18.05
21.73
23.42

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

tEpe j,n
22.66
18.05
11.54
5.58
0.48
-2.06
0.48
5.62
12.40
18.11
21.74
23.43

tEpe j,n

17
17
17
17
17
17
17
17
17
17
17
17

0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235

17
17
17
17
17
17
17
17
17
17
17
17

abs/ e csn
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235

ZONA JARDINIERE PARTER (Z1)


e
abs/ e cso
17
0.0471
17
0.0471
17
0.0471
17
0.0471

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

138.1
136.8
125.7
73.3
68.9
76.7
106.9
103.5
94.8
91.6
96.8
94.9

45
35.6
25.2
15.3
11.7
13.6
20.7
30
39.6
46.9
50.3
48.2

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

23.46
19.05
12.69
6.31
1.22
-1.26
1.50
6.46
12.95
18.38
21.99
23.74

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala SV I dif. Vert. t e


123.8
45
119.1
35.6
104.1
25.2
57.4
15.3
53
11.7
59.3
13.6
87.3
20.7
91.4
30
91.6
39.6
86
46.9
92.8
50.3
89.9
48.2

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

t Epe j,n
23.28
18.82
12.41
6.10
1.01
-1.49
1.25
6.30
12.90
18.31
21.93
23.67

0.7
0.7
0.7
0.7

I tot.oriz
I dif. oriz. t e
49.6
27.1
85
41.4
124.8
60
167.2
79.2

21.2
16.9
10.8
5.2

t Epe j,n
23.22
20.28
15.76
11.83

17
17
17
17
17
17
17
17

0.0471
0.0471
0.0471
0.0471
0.0471
0.0471
0.0471
0.0471

0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

17
17
17
17
17
17
17
17
17
17
17
17

abs/ e csn
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

august

septembr.

octombr.

205.6
233.5
200.8
233.2
175.5
114.2
54.2
41.3

93.9
100.7
96.3
90.1
71.1
50.4
30.6
23.5

I totala E I dif. Vert. t e


78
45
84.6
35.6
66
25.2
33
15.3
27.3
11.7
30.9
13.6
53.9
20.7
65.9
30
76
39.6
74.9
46.9
79.6
50.3
72.2
48.2

noiembr.

decembr.

0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

8.30
6.71
7.87
13.75
18.08
21.17
22.42
23.69

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

t Epe j,n
22.69
18.37
11.92
5.79
0.68
-1.86
0.82
5.97
12.70
18.17
21.76
23.44

ian.

febr.

martie

aprilie

mai

iunie

iulie

6060.54

4804.511 3050.356 1489.024 128.5488

-557.045 104.4459 1475.633 3275.316 4833.971 5819.511

6272.11

2297.704

1918.414 1379.606 884.8048 442.3936 211.8912 413.8512 846.5744 1420.222 1897.995 2207.605 2367.645

924.7546

736.6205 470.9474 227.7198

19.5888

-84.0686

19.5888 229.3522

506.044 739.0691 887.2094 956.1783

7230.372

5871.21 3911.058 1944.742

376.004

-388.332

462.3 1990.972

3991.19 5664.716 6777.318 7316.668

951.844 157.6004

-232.5

3632.611

2936.673 1936.456

12675.77

10262.4 6659.108 3234.584

4086.133

3165.02 1957.366 1010.085 278.6892

843.3128

671 428.6348 210.1572

379.882

58.5112

-1039.09

195.05

983.052 2012.916 2857.092 3421.957 3693.467

458.093 3335.141 7094.855 10150.67 12156.22 13094.76

-20.9344 434.3888

1275.69 2332.877 3422.774 4044.264

4179.03

-1.0736 106.8232 283.4304 510.7652 713.1388 832.8452 859.6852

9946.795

7908.647 5049.468 2494.568 904.9695 385.5957 1723.377 3730.048 6282.325 8616.884 9946.795 10075.33

3117.958

2688.156 2025.369 1092.589 615.6852 468.4927 936.9854 1381.086 1921.072 2397.135 2752.079 2875.721

3057.401

2593.408 1890.154 986.9475

502.446 340.9455

799.812 1309.094 1926.898 2391.746 2765.162 2883.083

19277.8

16650.37 12546.61 6666.994 4060.961 3449.035

6581.41 9422.798

1362.763

1177.028

243.815

465.245

3452.904

2972.424 2037.672 1018.836

387.66

153.972

691.236 1420.692 2308.488 2946.216 3402.672 3508.596

6.632

-79.584

702.992

560.404

886.93

358.128

471.295 287.0725

172.432

-3.316

12713.5 15049.95 17155.31 17634.58

666.105 898.7275 1063.893 1212.723 1246.603

159.168

374.708

553.772

669.832

729.52

8347.822

7290.863 5665.878 4253.003 2983.933 2412.312 2829.344 4943.263 6499.941 7610.827 8060.214 8516.792

1201.867

1049.693 815.7376 612.3208

3174.995
91394.49

3021.57 2718.33 2416.895 2084.775 1866.37 1828.465 2066.725 2351.915 2691.255 2933.125 3115.43
76278.41 53787.81 30138.84 14104.96 7477.113 18454.45 36230.52 57357.58 74696.86 86205.31 90551.39

429.608 347.3096 407.3512

711.7 935.8208 1095.759 1160.459 1226.194

TEMPERATURA INTERIOARA REDUSA - cf. rel. (8) din NP 048

ti R ti a

Sinc
SE
0,33 B1 na V
R

luna
august septembr. octombr. noiembr. decembr.
ian.
febr.
martie
aprilie
mai
iunie
S inc
2875.58 2875.58 2875.58 2875.58 2875.58 2875.58 2875.58 2875.58 2875.58 2875.58 2875.58
B1
1.182
1.182
1.182
1.182
1.182
1.182
1.182
1.182
1.182
1.182
1.182
na
0.435
0.435
0.435
0.435
0.435
0.435
0.435
0.435
0.435
0.435
0.435
V
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
SE/ R med 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81 3,361.81
ti med
19.57
19.57
19.57
19.57
19.57
19.57
19.57
19.57
19.57
19.57
19.57
a
5.68
5.68
5.68
5.68
5.68
5.68
5.68
5.68
5.68
5.68
5.68
tiR
16.34
16.34
16.34
16.34
16.34
16.34
16.34
16.34
16.34
16.34
16.34

iulie
2875.58
1.182
0.435
9944.3
3,361.81
19.57
5.68
16.34

Dimensiuni caracteristice elementelor de constructie - opace/ transparente


cf. C107/3 - 97
ALCATUIREA PERETILOR
Calculul rezistentelor termice unidirectionale in camp curent - cf. rel R=Rsi +i/a*i +Rse,
in care Rsi= 1/i si Rse= 1/e; i=6 sau 8 [W/m2K] si e = 12 sau 24 [W/m2K],
a=coef de maj a conductivitatii termice a mat. In functie de starea si vechimea lor, (in acest caz a=1)
cf. MC-001/1

PERETE EXTERIOR - PE1


nr. crt.
Elemente componente
1 Tencuiala int. - mortar de var
2 Zidarie din blocuri de BCA
3 Tencuiala ext. - mortar var/ciment
TOTAL
R = 1/i + Ro + 1/e
R' = r*R

1/i
0.125
0.125
0.125

i = 8

a
'=a* 1/e
Ro
e=24
W/mK m2K/W
0.01
0.7
1
0.7
0.042
0.014
0.35
0.35
1 0.350
0.042
1.000
0.02
0.87
1 0.870
0.042
0.023
1.037
1.204
0.963

i = 8
PERETE EXTERIOR - PE2 - pereti subsol - zona SUPRATERANA
1/i
nr. crt.
Elemente componente

a
'=a* 1/e
Ro
e=24
m
W/mK m2K/W
1 Tencuiala int. - mortar de var
0.125
0.01
0.7
1
0.7
0.042
0.014
2 Diafragma beton armat
0.125
0.3
2.03
1
2.03
0.042
0.148
3 Hidroizolatie
0.125 0.001
0.17
1
0.17
0.042
0.006
4 Polistiren extrudat
0.125 0.025
0.044
1 0.044
0.042
0.568
5 Zid prot. hidroizolatie - caramida
0.125 0.125
0.8
1
0.8
0.042
0.156
6 Tencuiala ext. - mortar var/ciment 0.125
0.02
0.87
1 0.870
0.042
0.023
TOTAL
0.915
R = 1/i + Ro + 1/e
1.082
R' = r*R
R1' = 0.865

PERETE EXTERIOR - PE2' - pereti subsol - zona SUBTERANA


1/i
nr. crt.
Elemente componente

a
m
W/mK 1 Tencuiala int. - mortar de var
0.125
0.01
0.7
2 Diafragma beton armat
0.125
0.3
2.03
3 Hidroizolatie
0.125 0.001
0.17
2 Polistiren extrudat
0.125 0.025
0.044
3 Zid prot. hidroizolatie - caramida
0.125 0.125
0.8
4 Pamant
0.125
2.15
1.16
TOTAL
R = 1/i + Ro + R pamant + 1/e
R' = r*R

'=a* 1/e
1
0.7
1
2.03
1
0.17
1 0.044
1
0.8
1
1.16

0.059
0.059
0.059
0.059
0.059
0.059

PERETE ADIACENT SP. NEINCALZITE (CAMERA TROLIU) - PE3


1/i
nr. crt.
Elemente componente

a
'=a* 1/e

i = 8
Ro + R p e=17
m2K/W
0.014
0.148
0.006
0.568
0.156
1.853
2.746
2.930
R2' = 2.344

Ro

i = 8
e=12

m
1 Tencuiala int. - mortar de var
2 Zidarie blocuri BCA
3 Tencuiala int. - mortar de var
TOTAL
R = 1/i + Ro + 1/e
R' = r*R

0.125
0.125
0.125

0.01
0.35
0.01

W/mK 0.7
1
0.35
1
0.7
1

0.7
0.35
0.7

0.084
0.084
0.084

m2K/W
0.014
1.000
0.014
1.029
1.238

i = 8
PERETE EXTERIOR -DIAFRAGMA B.A. - PE4
1/i
nr. crt.
Elemente componente

a
'=a* 1/e
Ro
e=24
m
W/mK m2K/W
1 Tencuiala int. - mortar de var
0.125
0.01
0.7
1
0.7
0.042
0.014
2 Diafragma b.a.
0.125
0.3
2.03
1
2.03
0.042
0.148
3 Termoizolatie - polistiren expandat 0.125
0.05
0.044
1 0.044
0.042
1.136
4 Tencuiala ext. - mortar var/ciment 0.125
0.02
0.87
1 0.870
0.042
0.023
TOTAL
1.321
R = 1/i + Ro + 1/e
1.488
R' = r*R
PERETE CORTINA - PE5
R = 0.9 m2K/W
i = 6
PLANSEU PESTE SUBSOL 2 - pardoseala rece (gresie)
1/i
nr. crt.
Elemente componente

a
'=a* 1/e
Ro
e = 12
m
W/mK m2K/W
1 Finisaj - gresie
0.167
0.01
2.03
1
2.03
0.084
0.005
2 Sapa mortar de ciment
0.167
0.04
0.93
1
0.93
0.084
0.043
3 Placa beton armat
0.167
0.2
2.03
1
2.03
0.084
0.099
4 Termoizolatie polistiren expandat
0.167
0.05
0.044
1 0.044
0.084
1.136
5 Tencuiala interioara
0.167 0.015
0.7
1
0.7
0.084
0.021
TOTAL
1.304
R = 1/i + Ro + 1/e
1.555

i = 8
PLANSEU PESTE SUBSOL 1 - ZONA INTRARII (JARDINIERE) - A1
1/i
nr. crt.
Elemente componente

a
'=a* 1/e
Ro
e = 24
m
W/mK m2K/W
1 Gresie
0.125
0.01
0.7
1
0.7
0.042
0.014
2 Sapa - mortar de ciment
0.125
0.04
0.93
1
0.93
0.042
0.043
3 Hidroizolatie bituminoasa
0.125
0.01
0.17
1
0.17
0.042
0.059
4 Placa beton armat
0.125
0.2
2.03
1
2.03
0.042
0.099
5 Termoizolatie - polistiren
0.125
0.05
0.044
1 0.044
0.042
1.136
6 Tencuiala int. - mortar de ciment
0.125 0.015
0.7
1
0.7
0.042
0.021
TOTAL
1.372
R = 1/i + Ro + 1/e
1.539

i = 6
PLANSEU PESTE PARTER - peste zona intrarii - pardoseala calda (mocheta) - A2
1/i
nr. crt.
Elemente componente

a
'=a* 1/e
Ro
e = 24
m
W/mK m2K/W
1 Finisaj - mocheta
0.167 0.005
0.29
1
0.29
0.042
0.017

2
3
4
5

Sapa mortar de ciment


Placa beton armat
Termoizolatie polistiren expandat
Tencuiala exterioara
TOTAL
R = 1/i + Ro + 1/e

0.167
0.167
0.167
0.167

0.045
0.15
0.05
0.02

0.93
2.03
0.044
0.87

1
0.93
1
2.03
1 0.044
1
0.87

0.042
0.042
0.042
0.042

0.048
0.074
1.136
0.023
1.299
1.508

i = 8
PLANSEU PESTE NIVELUL 6 (TERASA CIRCULABILA)
1/i
nr. crt.
Elemente componente

a
'=a* 1/e
Ro
e = 24
m
W/mK m2K/W
1 Strat uzura - gresie
0.125 0.015
2.03
1
2.03
0.042
0.007
2 Sapa - mortar de ciment
0.125
0.04
0.93
1 0.930
0.042
0.043
3 Hidroizolatie bituminoasa
0.125
0.01
0.17
1
0.17
0.042
0.059
4 Termoizolatie BCA
0.125
0.15
0.24
1
0.24
0.042
0.625
5 Bariera contra vaporilor
0.125 0.002
0.17
1
0.17
0.042
0.012
6 Beton de panta
0.125
0.12
0.93
1
0.93
0.042
0.129
7 Placa beton armat
0.125
0.15
2.03
1
2.03
0.042
0.074
8 Tencuiala int. - mortar de ciment
0.125 0.015
0.7
1
0.7
0.042
0.021
TOTAL
0.970
R = 1/i + Ro + 1/e
1.137

i = 8
PLANSEU PESTE NIVELUL 7 (TERASA NECIRCULABILA)
1/i
nr. crt.
Elemente componente

a
'=a* 1/e
Ro
e = 24
m
W/mK m2K/W
1 Strat uzura - pietris
0.125
0.04
0.7
1
0.7
0.042
0.057
2 Sapa - mortar de ciment
0.125
0.04
0.93
1 0.930
0.042
0.043
3 Hidroizolatie bituminoasa
0.125
0.01
0.17
1
0.17
0.042
0.059
4 Termoizolatie BCA
0.125
0.15
0.24
1
0.24
0.042
0.625
5 Bariera contra vaporilor
0.125 0.002
0.17
1
0.17
0.042
0.012
6 Beton de panta
0.125
0.12
0.93
1
0.93
0.042
0.129
7 Placa beton armat
0.125
0.15
2.03
1
2.03
0.042
0.074
8 Tencuiala int. - mortar de ciment
0.125 0.015
0.7
1
0.7
0.042
0.021
TOTAL
1.020
R = 1/i + Ro + 1/e
1.187

USI EXTERIOARE - METALICE


nr. crt.
Elemente componente
Foaie de tabla
2 Strat int. termoizolant -poliuretan
3 Foaie de tabla
TOTAL
R = 1/i + Ro + 1/e

i = 8

a
'=a* 1/e
Ro
e = 24
m
W/mK m2K/W
0.125 0.0015
58
1
58
0.042
0.000
0.125 0.035
0.044
1 0.044
0.042
0.795
0.125 0.0015
58
1
58
0.042
0.000
0.795
0.962

1/i

r = 0.8

r = 0.8

r = 0.8

r = 0.9 ?
R' = 1.114
nr. crt. Elemente de constructie

A
mp

r = 0.8
R' = 1.190

r = 0.75
R' = 1.166

r = 0.75
R' = 1.154

1
2
3
4
5
6
7
8
9

PE1
PE2
PE2'
PE4
Planseu peste subsol 2
planseu peste subsol 1 - aria A1
planseu peste parter - aria A2
planseu peste ult. nivel - terasa
ferestre termoizolante - rama PVC
F1
10 perete cortina - F2

1143.5
69.84
165.76
88.94
327.06
35.6
58.54
347.29

m2K/W
1.204
1.082
2.93
1.488
1.555
1.539
1.508
1.137

258.28
648.44

0.55
0.9

coeficient
coeficient
punti termice reducere
%
20
0.8
20
0.8
20
0.8
20
0.8
25
0.75
25
0.75
25
0.75
15
0.85
-

r = 0.75
R' = 1.131

r = 0.85
R' = 0.966

r = 0.85
R' = 1.009

R' = r*R
m2K/W
0.963
0.866
2.344
1.190
1.166
1.154
1.131
0.966
0.55
0.9

SUPRAFETE PERETI OPACI

NORD
subsol
parter
et. 1 - 4
et. 5, 6
et. 7
TOTAL
SUD
subsol
parter
et. 1 - 4
et. 5, 6
et. 7
TOTAL
EST
subsol
parter
et. 1 - 4
et. 5, 6
et. 7
TOTAL
N-V
subsol
parter

PE1, PE2, PE4


1.16*(10.3+1.625)
(10.58+1.625)*24.5

11.03*2.95

PE1, PE2, PE4


1.16*(10.76+1.625)
(11.73+1.625)*24.5

5.17*2.95

PE1, PE2
1.16*22.45
22.85*24.5

S-V
subsol
parter

S pereti=S1 S ferestre = S2
13.83
3.36

PE1, PE2
1.16*10.22
1.78*3.5+1.65*21

PE1, PE2
1.16*20.15
10*3.5+4.27*21

68.6

230.42

32.54
345.39

32.54
273.43

S pereti=S1 S ferestre = S2
14.37
2.16

10.56*0.36

S1 - S2
12.21

311.76

44.1

267.66

15.25
341.38

15.25
295.12
S1 - S2
22.02

559.83

54.6

505.23

9.145
595.015

1.44

7.705
534.955

S pereti=S1 S ferestre = S2
11.85
2.16

S1 - S2
9.69

40.88

12.6

28.28

0
52.73

0
37.97

S pereti=S1 S ferestre = S2
23.37
7.92
133.7

et. 1 - 4
et. 5, 6
et. 7
TOTAL

S1 - S2
10.47

299.02

S pereti=S1 S ferestre = S2
26.04
4.02

3.10*2.95

et. 1 - 4
et. 5, 6
et. 7
TOTAL

SUPRAFETE VITRATE - GE
F1 = ferestre termoizolante
F2 = perete cortina , R2=0.9

3.8
160.87

4.8

S-E
FARA ORIENTARE - INTRARE (PE1) + SUBSOL (PE2' - SUB CTA)

S1 - S2
15.45

NORD
subsol
parter
et. 1 - 4
et. 5, 6
et. 7
TOTAL
SUD
subsol
parter
et. 1 - 4
et. 5, 6
et. 7
TOTAL
EST
subsol
parter
et. 1 - 4
et. 5, 6
et. 7
TOTAL
N-V
subsol
parter
et. 1 - 4
et. 5, 6
et. 7
TOTAL
S-V
subsol
parter
et. 1 - 4
et. 5, 6
et. 7
TOTAL

128.9

3.8
148.15
0

S-E
subsol
parter
et. 1 - 4
et. 5, 6
et. 7
TOTAL

subsol
parter

2.15*77.10
3.61*3.5

et. 1 - 4
et. 5, 6
et. 7
TOTAL

165.76

165.76

12.64

12.64

0
178.4

0
178.4

PERETI ADIACENTI SP. NEINCALZITE


et. 7
9.89*2.95
TOTAL

S inc =
V inc =

=
=
=
=
=
=
=

TOTAL
FERESTRE

29.17
29.17

TOTAL PERETI OPACI/ SUPRAFETE VITRATE

S subsol1
S parter
S et. 1-4
S et. 5,6
S et. 7
S terasa circ
S terasa necirc

FARA ORIENTARE - ZONA


parter
TOTAL

327.06
297.39
356.02
360.7
105.65
347.29
13.4

1497.20

P sbs1
P parter
P et. 1-4
P et. 5,6
P et.7

= 77.10
= 81.74
= 82.54
= 82.08
= 53.74

2875.58 mp
9944.3 mc

SE = 2403.91 + U1+U2 + A1 + A2 + A3 + S sbs1 + S terasa +S per troliu = 2403.91+1.89+3.15+35.6+58.54+4.7+ 327.06 + 3

A anv = 77.13*3.31+83.62*3.5+82.54*14+82.08*7+53.72*2.95+A1+A2+A3+S sbs+S terasa = 255.30+292.67+1155.56+574.56


PE1
NORD
N-V
S-V
SUD
S-E
EST
F. O.
TOTAL
R'
Spej/R' pej

R med =

174.03
28.28
132.7
282.91
0
512.94
12.64
1143.5
0.963
1187.44

PE2
PE2'
PE3
PE4
F1
F2
10.47
88.94
71.96
0
9.69
0
14.76
236.08
15.45
0
47
385.13
12.21
0
46.26
0
0
0
0
27.23
22.02
0
60.06
0
0
165.76
29.05
0
18.24
0 terasa
69.84
165.76
29.05
88.94
258.28
648.44
347.29
0.865
2.344
1.114
1.19
0.55
0.9
0.966
80.74
70.72
26.08
74.74
469.60
720.49
359.51

SE
(Spej/R'pej) + (Sfn/Rfn) + (Sp/R'p)

3224.59 =
3361.81

S
R'
Spej/R' pej

0.959

terasa
347.29
0.966
359.51

SUPRAFETE VITRATE - GEAM TERMOIZOLANT/ PERETE CORTINA


F1 = ferestre termoizolante, rama Al., R1=0.55
F2 = perete cortina , R2=0.9
F1
1.1*06*4+1.2*.6
1.1*1.75*4+1.2*1.75
9.8*4
9.8*2
0

F2
3.36
9.8
39.2
19.6
0
71.96

0
0
0
0
0

2.16
6.3
25.2
12.6
0
46.26

0
0
0
0
0

4.02
7.8
31.2
15.6
1.44
60.06

0
0
0
0
0

F1
1.2*.6*3
1.1*1.75*4+1.2*1.75
9.8*4

F2

F1
1.1*.6+1.2*.6*4+.8*.6
1.6*.9+1.2*(0.9+1.75)*2
9.8*4

F2

F1
1.2*.6*3

0
F2

2.16
0
0
12.6 (7.3+2.65+0.575)*20.81

0
1.2*1.75*6

219.03

0 6.96*2.45
14.76
F1
1.2*.6*11
11.82*2.9+2.4*2
0

17.05
236.08
F2

7.92
0
39.08
0 (1.8+15.4)*20.81

357.93

0 11.10*2.45
47
F1

27.195
385.13
F2

0
0
0

0
0
0
0 0.725*20.81

15.08

0 4.96*2.45
0

12.15
27.23

FARA ORIENTARE - ZONA INTRARII


2.34*2.9+3.95*2.9

18.24
18.24

FERESTRE

F1
258.28

258.28

F2

648.44

906.72

648.44

2403.91

5+35.6+58.54+4.7+ 327.06 + 360.69 + 29.05 = 3224.59

55.30+292.67+1155.56+574.56+158.44+35.6+58.54+4.7+327.06+347.29 = 3223.22
pt. denumirea peretilor vezi pg de rezistente termice
F.O. = pereti fara orientare

subsol 1 A2-peste parter A1


A3
Usi metalice
327.06
58.54
35.6
4.7
5.04
1.166
1.131
1.154
1.131
0.962
280.5
51.76
30.85
4.15
5.24

subsol 1 A2-peste parter A1


A3
Usi metalice
327.06
58.54
35.6
4.7
5.04
1.166
1.131
1.154
1.131
0.962
280.5
51.76
30.85
4.15
5.24

3182.04
3361.81

CONSUMUL ANUAL DE CALDURA - rel. 1 NP 048


Consumul anual de caldura pentru incalzirea cu intermitenta
a zonei principale a cladirii cu relatia (1) din NP 048-2000
NGZ = 1833.97
an
Q inc =

0.024

0.024* (SE/R med + 0.33* B 1*na *V) * C * Ngz =

3361.81

an
an
Q Sinc = Q inc +

0.33

an
Q cs
inc

0.435

9944.3

0.892

an
Qcs = 0

inc = r * d * g =

0.000

r=
0.99
d=
1
g = o * ( go - v) =

an
an
Q Sinc = Q inc
inc

1.182

198236.680

o = 0.98
go = 0.92
v = 0.02

0.882

227075.23 kWh/an

Consumul specific de caldura anual


an
q inc =

an
Q inc
Sinc

68.94

kWh/mp, an

an
q Sinc =

an
Q Sinc
Sinc

78.97

kWh/mp, an

=>

CLASA A

1. Necesarul de caldura pt prepararea apei calde de consum efectiv utilizate


Qacc = Qac + Qac,p
Qac = *c*Vac*(ac - ar) =
40656.01 kWh/an
ac = 60 gr C
Vac = a*Np/1000 = 5*365*390/1000 = 711.75
mc
ar = 12.5 gr C
2. Pierderile totale de cldur corespunztoare instalaiei de alimentare cu ap cald de consum
Qac,p = Qac,c + Qac,d + Qac,s =

3814.66

kWh/an

Qac,c =*c*Vac,c*(ac,c-ar) =

3814.66

kWh/an

ac,c = 40 gr C
ar = 10 gr C

1833.97

Vac + Vac,c = Vac *f1*f2 = 711.75*1.1*1.05 = 822.07


Vac,c = 722.07 - Vac = 110.32
983.2
992.2

4183
4182

711.75
110.32

60
40

f1 = 1.1 pt. obiective alimentate in sistem local


f2 = 1.05 pt. inst. Echipate cu baterii monocomanda
10
10

3600000
3600000

40656.01
3814.66

Qac,d = 0 pierderi pe conductele de distributie


Qac,s = 0 pierderi in sistemul de acumulare (prin mantaua boilerului)
Qacc = Qac + Qac,p =
qacc = Qacc/ Sinc =

44470.67 kWh/an
15.46
kWh/mp, an

=>

Consumul anual de energie electrica pt iluminat


W ilum = 6*Sinc + tu*Pn =

122253.48 kWh/an

tu =( tD*FD*FO) + tN*FO =
Pn =
42
kW
S inc =
2875.58
mp
q ilum = Wilum / Sinc =

2500 h

42.52 kWh/mp,an

=>

CLASA B

Consumul anual de energie electrica pt climatizare


qclim =

43.86 kWh/mp,an

=>

CLASA B

Consumul anual specific de energie al cladirii


qT = qinc + qacc + qil + qclim =

170.78

kWh/mp,an

CLASA B

CLASA B

Emisia de CO2

E co2 = Q Sinc*fh,co2 + Qacc*fw,co2 + Qclim*fclim,co2 + Qil*fil, co2


fh,CO2 = 0.205
fw,CO2 = 0.09
fclim,co2 = 0.09
fil,co2 = 0.09
198236.68

[kg / kWh]
[kg / kWh]
[kg / kWh]
[kg / kWh]

[kg CO2 /an]

cf. tab. 1.13 si 1.14

Indicele de emisie echivalent CO2

Ico2 =

E co2
S inc

23.28

[kg CO2 / mp, an]

I co2 = qinc*fj,CO2 + qacc*fw,CO2 + qil*fi,CO2 + q clim*fCO2 =


68.94*0.205 +15.46*0.09 + 42.52*0.09 + 43.86*0.09 =

24.86

14.13 + 1.39+ 3.82 + 3.94 = 23.28

Notarea energetica a cladirii analizate

exp B1 qT po B2 ,
N

100,

pentru
pentru

qT po qTm kWh / m2an


qT po qTm kWh / m2an

po = p1*p2*.p12 = 1
Cazul 2 -

caz
1
2
3
4

Utilitati:

B1
0.001053
0.000761
0.001016
0.000742

N = 98.06

- incalzire
- apa calda de consum
- iluminat
- climatizare
B2
4.73677
4.71556
4.73724
4.71646

pentru ca

qTm
125
145
130
150

qTM
820
1120
850
1150

qT*1>qTm kWh/Mp, an
(188.29>145)

rii monocomanda

[kg CO2 /an]

9+ 3.82 + 3.94 = 23.28

po qTm kWh / m 2 an
kWh / m 2 an

ai=

v
P=
Qsm=

26

8500

m3/h

380
68.91

Pa
kW

8500

cp=

cp=
v=
U'=A x U
A=

1
70
3.36
3224.59

U=1/Rmed

1.043

Rmed=

0.959

X=Xe - Xs

0.0025

Xe=

0.0118

Xs=

0.0093

aezi

pt a transforma in m3/s impart la


3600

2.36

pt a transforma in kg/s
2.83
kg/s
inmulteste cu 1.2 si se imparte la
3600
cand impart P la cp, at cp este
1000
KJ/kg0C
egal cu
at cand impart Qsm si U' la cp
KJ/kg0C
%
kW/K
aria pardoseli utile
m2
coef global de transfer termic al
0.0010428
kW/m2 0C elem de constructie, impart la
kW/m2K
1000
2
m K/W
diferenta medie de continut de
kg/kg
umiditate
continutul de umiditate al erului cu grad de asigurare de
kg/kg
95 %
exterior
continutul de umiditate la bateria
kg/kg
temp la iesire de 12.5 0C
de racire
temp medie a aer ext pe per de
0
C
ocupare a inc clim
interv orar
8
luna
15.2
V
18.2
VI
20.2
VII
20.2
VIII
15.2
IX
m3/h

luna
V
VI
VII
VIII
IX
k=
N=

0.71
153

aem

luna
V
VI
VII

16.7
20.2
22

m3/s

C
C
0
C
0
C
0

constanta
nr de zile pt luna de calcul
considerata
temp medie lunara a aerului ext

ai
0
C
26
26
26
26
26

VIII
IX

21.2
16.9

0
0

C
C
luna
V
VI
VII
VIII
IX

Qr=

230574.98

kWh

COP=

2.68

QenIF=

86035.44

kWh

V'=

0.00050971

m3/m2h
3/

Psp=

0.56

W/m h

A clim=

1961.9

m2

subsol 1=
parter=
etaj1=
etaj2=
etaj3=
etaj4=
etaj5=
etaj6=

179
222.3
258.7
258.7
258.7
258.7
262.9
262.9

m2
m2
m2
m2
m2
m2
m2
m2

necesarul de energie pt racire si


dezumificare
coef de performanta al chillerului
consumul de energie al instalatiei
frigorifice

putere specifica ventilator data in


Anexa II.2.L in metod partea a IIIa, in functie de tipul de
instalatie(dest incap)

puterea electrica specifica pentru


antrenarea ventilatorului
nr de ore de functionare la
2750
h/an
sarcina nominala, val obtinuta
Nh=
din Anexa II.2.K
consum
specific de energie
0.000784953 kWh/m2an
Qv=
electrica al ventilatorului
kW
puterea absorbita de pompa
Pabs_pompa= VCC+CH+BR
756
W
VCC1=
756
W
VCC2=
1.512
kW
ventiloconvector
VCC=
11
kW
chiller
CH=
0.316
kW
baterie racire
BR=
12.828
kW
Pabs_pompa=
70
%
randamentul motorului
motor=
puterea electrica consumata de
18.33
kW
Pel_motor=
motorul pompei
Qvt + Pel_motor
Qaux=
Pv=

0.000285438

W/m2

N
zile
31
30
31
31
30

Qt=
Qvt =
Qt / A clim

19.87
Qaux + QenIF
86055.31
1.54
43.86
kWh/m2an

consumul total de energie

=>

CLASA B

factor partial de corectie datorita orizontului; 1


daca nu sunt ladiri in jur, tabel H4 Anexa H
SR EN ISO 13790 daca sunt cladiri in jur

Fh=

orientare
N
NV
NV
SV
SV
S
SE
E
factor partial de corectie pentru proeminente;
1 daca nu exista, tabel H3 Anexa H SR EN
ISO 13790 daca exista proeminente

F0=

orientare
N
NV
NV
SV
SV
S
SE
E
factor partial de corectie pentru aripioare; 1
daca nu exista, tabel H5 Anexa H SR EN ISO
13790 daca exista aripioare

Ff=

orientare
N
NV
NV
SV
SV
S
SE
E
FF=

0.839

Fw=

0.9

g_l_=

factor de corectie pt ramele


vitrajelor
factor de transmisie solara
transmitanta totala la energia
solara pt rad perpendiculare pe
vitraj

g_l_=
g_l_=

0.85
0.75

vitraj simplu
vitraj dublu

g_l_=

0.67

vitraj dublu cu acoperire selectiv

g_l_=

0.7

g_l_=

0.5

g_l_=
g=

0.75
Fw x g_l_
0.675
Fh x F0 x Ff

vitraj triplu
vitraj triplu cu 2 acoperiri
selective
fereastra dubla

Fs=

factor de umbrire a suprafetei


orientare
N
NV
NV
SV
SV
S
SE
E

A=

906.72

m2
m2

As=

aria totala a elementului vitrat


aria receptoare echivalenta a suprafetei
vitrate pe orientarea corespunzatoare
orientare
N
NV
NV
SV
SV
S
SE
E

W/m2

Is=

radiatia totala medie pe perioada de calcul pe


o suprafata de 1 m2 pe orientarea

luna
mai
iunie
iulie
august
septembrie
Qs=

(Is x As)

aporturile solare prin elementele


vitrate

Aporturi totale pe orienta


orientare

N
NV
NV
SV
SV
S
SE
E
TOTAL

Qilum+om=

24680.7

12.58 W/m2 inmultit cu suprafata


climatizata m2
MC 001/2 climatizare Anexa II
2D tab D2

10

11

12

13

14

15

16

aezi

18
21
23
23
18

20.5
23.5
25.5
25.5
20.5

22.1
25.1
27.1
27.1
22.1

23.1
26.1
28.1
28.1
23.1

23.7
26.7
28.7
28.7
23.7

24.1
27.1
29.1
29.1
24.1

24.3
27.3
29.3
29.3
24.3

24.1
27.1
29.1
29.1
24.1

21.68
24.68
26.68
26.68
21.68

v
m3/s
2.36
2.36
2.36
2.36
2.36

P
Pa
380
380
380
380
380

m
kg/s
2.83
2.83
2.83
2.83
2.83

cp

v
%
0.7
0.7
0.7
0.7
0.7

Qsm
kW
68.91
68.91
68.91
68.91
68.91

cp
KJ/kg0C
1
1
1
1
1

U'
kW/K
3.36
3.36
3.36
3.36
3.36

aezi
0
C
21.68
24.68
26.68
26.68
21.68

1000
1000
1000
1000
1000

7.373282
12.58571

aem
0

C
16.7
20.2
22
21.2
16.9

b
0

C
0.36
-3.20
-5.58
-5.58
0.33

k
0.71
0.71
0.71
0.71
0.71

NGZ
grade-zile
506.54
702.00
854.98
830.18
497.10
3390.81

Fh
1
1
1
1
1
1
1
1

F0
1
1
0.78
0.75
1
1
1
1

Ff
1
1
1
1
1
1
1
1

F0
1
1
0.78
0.75
1
1
1
1

Fh
1
1
1
1
1
1
1
1

Ff
1
1
1
1
1
1
1
1

Fs
1
1
0.78
0.75
1
1
1
1

A
m2
71.96
236.08
14.76
47
385.13
46.26
27.23
60.06

Fs

FF

1
1
0.78
0.75
1
1
1
1

0.839
0.839
0.839
0.839
0.839
0.839
0.839
0.839

0.675
0.675
0.675
0.675
0.675
0.675
0.675
0.675

zile
N
31
30
31
31
30

65.9
76.9
70.1
73.7
51.2

Aporturi totale pe orientari


As
Is
2
m
W/m2

67.61

Qs
W

orientare
N
NV
NV
SV
SV
S
SE
E

A
m2
71.96
236.08
14.76
47
385.13
46.26
27.23
60.06

As
m2
40.75
133.70
6.52
19.96
218.11
26.20
15.42
34.01

Valorile medii ale intensitatii radiatiei solare pentru per de incalzire


intensitatea rad solare
W/m2
NV
SV
S
70.4
86
91.6
78.2
92.8
96.8
71.15
102.27
111.57
71.1
89.9
94.9
75.8
123.8
138.1
60.1
119.1
136.8

40.75
133.70
6.52
19.96
218.11
26.20
15.42
34.01
TOTAL

67.61
71.15
71.15
102.27
102.27
111.57
102.27
77.80

2755.1
9512
463.87
2041.7
22307
2923
1577.1
2646.4
44226

Consumul specific mediu a

Calculul aporturilor de caldura a

Qsm = Qi + Qs

Q i i ,h (1 b ) i ,u
i = 6.1 W/mp
i,h = i*Aclim
i,u = 0

Qi = 12.58*1961.9 =

sj

Asnj = A*Fs*FF*g

X
kg/kg
0.0025
0.0025
0.0025
0.0025
0.0025

b
0
C
0.36
-3.20
-5.58
-5.58
0.33

Fs = Fh*Fo*Ff

mai
16.7

[mp]

A snj

e incalzire

SE
86
92.8
89.9
123.8
119.1

102.27

74.9
79.6
72.2
78
84.6

77.80

Consumul specific mediu anual de energie electrica pentru climatizare


Calculul aporturilor de caldura ale cladirii

Qsm = Qi + Qs

(Qsm = Qg)

Q i i ,h (1 b ) i ,u
i = 6.1 W/mp
i,h = i*Aclim

69.48

aporturi interne

fluxul mediu al degajarilor interne in spatiile incalzite

fluxul mediu al degajarilor interne in spatiile neincalzite

Qi = 12.58*1961.9 =

sj

24680.7 W

A snj

aporturi solare

44799 W

Isj = radiatia solara totala pe perioada de calcul pe o suprafata de 1 mp avand orientarea j


[W/mp]
Asnj = aria echivalenta a supraf n , avand orientarea j
Asnj = A*Fs*FF*g

[mp]

[mp]

A = aria elem vitrat


Fs = factor de umbrie a suprafatei n

Fs = Fh*Fo*Ff

Fh = factorul partial de corectie datorita orizontului =


1
Fo = factorul partial de corectie pentru proeminente =
1
(sau tabel H4, anexa H, SR EN 1
Ff = factorul de corectie pt. aripioare = 1 (sau tabel H4, anexa H, SR EN 13780)
FF = factorul de reducere pt rama vitrajelor =
0.839
g = transmitanta totala la energie solara a suprafetei n

iunie

iulie

aug.

sept.

20.2

22.0

21.2

16.9

aem

Calculul consumului de energie pentru rcire i dezumidificare

NGZ

N aem b

1 e k aem b

b a i

(sau tabel H4, anexa H, SR EN 13780)

grade zile

Qs
vP
U'
aezi ai 2400x
m
m c pv m c p m c p

e pentru rcire i dezumidificare

grade zile

U'
aezi ai 2400x
m c p

CLADIREA DE REFERINTA
Rezistente termice minime , R'min, ale componenetlor anvelopei, pt cladiri cu alta destinatie
decat locuirea, cf. MC001/ partea I, tabelul 11.5, pt cladiri de categoria 1
nr. crt.

Elementul anvelopei
1
2
3
4

R' min
[mpK/W]
pereti opaci
1.25
planseu peste ultimul nivel
3.2
(terasa)
planseu peste subsol 2
1.05
(sp. neincalzit)
elemente transparente
0.43
(ferestre termoizolante,
fatada cortina)

R1'min
R2'min
R3'min
R4'min

TEMPERATURA EXT. ECHIVALENTA CARACTERISTICA PERETELUI EXT.TRANSPARENT


=0.3, R'min= 0,43 - ferestre termoizolante, perete cortina
csn = 0,55

t EF

n RFn csn I Tn 1 csn I dif n t e

NORD

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

R4'min
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26

csn
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala N I dif. Vert.


te
73.7
45
51.2
35.6
25.2
25.2
15.3
15.3
11.7
11.7
13.6
13.6
20.7
20.7
30
30
39.6
39.6
65.9
46.9
76.9
50.3
70.1
48.2

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

t'Fn (R4'min)
28.00
21.84
13.62
6.91
1.51
-0.88
2.21
8.15
15.73
23.11
27.46
28.74

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I tot N-V
I dif. Vert.
te
75.8
45
60.1
35.6
36.3
25.2
16.5
15.3
12.3
11.7
14.9
13.6
28
20.7
38.9
30
52.8
39.6
70.4
46.9
78.2
50.3
71.1
48.2

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

t'Fn (R4'min)
28.12
22.39
14.30
6.98
1.54
-0.80
2.66
8.70
16.54
23.39
27.54
28.80

N-V

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

R4'min
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26

csn
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43

SUD

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

R4'min
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26

csn
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala S
I dif. Vert.
te
138.1
45
136.8
35.6
125.7
25.2
73.3
15.3
68.9
11.7
76.7
13.6
106.9
20.7
103.5
30
94.8
39.6
91.6
46.9
96.8
50.3
94.9
48.2

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

t'Fn (R4'min)
31.96
27.10
19.80
10.48
5.03
3.00
7.51
12.67
19.12
24.69
28.68
30.26

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala SV I dif. Vert.


te
123.8
45
119.1
35.6
104.1
25.2
57.4
15.3
53
11.7
59.3
13.6
87.3
20.7
91.4
30
91.6
39.6
86
46.9
92.8
50.3
89.9
48.2

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

t'Fn (R4'min)
31.08
26.01
18.47
9.50
4.05
1.93
6.31
11.93
18.92
24.35
28.44
29.95

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala SV I dif. Vert.


te
123.8
45
119.1
35.6
104.1
25.2
57.4
15.3
53
11.7
59.3
13.6
87.3
20.7
91.4
30
91.6
39.6
86
46.9
92.8
50.3
89.9
48.2

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

t'Fn (R4'min)
31.08
26.01
18.47
9.50
4.05
1.93
6.31
11.93
18.92
24.35
28.44
29.95

SUD-VEST

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

R4'min
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26

csn
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43

SUD-EST

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

R4'min
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26

csn
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43

EST

R4'min

csn

I totala E

I dif. Vert.

te

t'Fn (R4'min)

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26

NORD
N-V
S-V
SUD
S-E
EST
F. O.
TOTAL
R' min
Spej/R'min

PE1
PE2
174.03
28.28
132.7
282.91
0
512.94
12.64
1143.5
1.25
914.80

R med =

luna
tEpe1 NORD
Spe1/Rpe1 (N)
tEpe2 NORD
Spe2/Rpe2 (N)
tEpe4 NORD
Spe4/Rpe4 (N)
tEpe1 F.O.
Spe1/Rpe1 (FO)
tEpe2' F.O.
Spe2'/Rpe2' (FO)
tEpe3 F.O.
Spe3/Rpe3 (FO)
tEpe1 N-V
SPE1/RPE1(NV)
tEpe2 N-V
SPE2/RPE2(NV)
tEpe1 SUD
SPE1/RPE1 (S)
tEpe2 SUD

0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

PE2'
10.47
9.69
15.45
12.21
0
22.02
0
69.84
1.25
55.87

78
84.6
66
33
27.3
30.9
53.9
65.9
76
74.9
79.6
72.2

PE3
165.76
165.76
1.25
132.61
?

PE4
29.05
29.05
1.25
23.24

SE
(Spej/R'pej) + (Sfn/Rfn) + (Sp/R'p)
august
22.63
139.22
22.63
8.38
22.63
71.15
21.20
10.11
21.20
132.61
19.95
23.24
22.66
22.62
22.66
7.75
23.46
226.33
23.46

septembr.
17.94
139.22
17.94
8.38
17.94
71.15
16.90
10.11
16.90
132.61
19.23
23.24
18.05
22.62
18.05
7.75
19.05
226.33
19.05

octombr.
11.39
139.22
11.39
8.38
11.39
71.15
10.80
10.11
10.80
132.61
18.18
23.24
11.54
22.62
11.54
7.75
12.69
226.33
12.69

45
35.6
25.2
15.3
11.7
13.6
20.7
30
39.6
46.9
50.3
48.2

F1
88.94
0
0
0
0
0
0
88.94
1.25
71.15
1497.1

noiembr.
5.56
139.22
5.56
8.38
5.56
71.15
5.20
10.11
5.20
132.61
17.21
23.24
5.58
22.62
5.58
7.75
6.31
226.33
6.31

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

28.26
23.89
16.13
8.00
2.47
0.18
4.26
10.36
17.97
23.67
27.63
28.86

F2
71.96
14.76
47
46.26
0
60.06
18.24
258.28
0.43
600.65

0
236.08
385.13
0
27.23
0
0
648.44
0.43
1508.00

3224.59 =
3824.50
decembr.
0.48
139.22
0.48
8.38
0.48
71.15
0.20
10.11
0.20
132.61
16.32
23.24
0.48
22.62
0.48
7.75
1.22
226.33
1.22

ian.
-2.08
139.22
-2.08
8.38
-2.08
71.15
-2.40
10.11
-2.40
132.61
15.84
23.24
-2.06
22.62
-2.06
7.75
-1.26
226.33
-1.26

febr.
0.39
139.22
0.39
8.38
0.39
71.15
-0.10
10.11
-0.10
132.61
16.19
23.24
0.48
22.62
0.48
7.75
1.50
226.33
1.50

SPE2/RPE2 (S)
tEpe1 S-V
SPE1/RPE1(SV)
tEpe2 S-V
SPE2/RPE2(SV)
tEpe1 EST
SPE1/RPE1 (E)
tEpe2 EST
SPE2/RPE2 (E)
tEFn1 NORD
SFn1/RFn (N)
tEFn1 N-V
SFn1/RFn1 (NV)
tEFn2 N-V
SFn2/RFn2 (NV)
tEFn1 SUD
SFn1/RFn1 (S)
tEFn1 S - V
SFn1/RFn1 (SV)
tEFn2 S - V
SFn2/RFn2 (SV)
tEFn2 S-E
SFn2/RFn2 (S)
tEFn1 EST
SFn1/RFn1 (E)
tEFn1 F.O.
SFn1/RFn1 (FO)
tp terasa
Sp/Rp terasa
tE plan parter
Sp/Rp pl parter
tE subsol 2
Sp/Rp subsol 1
1+2+3
SE/R
tev

9.77
23.28
106.16
23.28
12.36
22.69
410.35
22.69
17.62
28.00
167.35
28.12
34.33
28.12
549.02
31.96
107.58
31.08
109.30
31.08
895.65
31.08
63.33
28.26
139.67
21.20
42.42
23.22
108.53
23.22
33.90
17.59
311.49
98499.19
3,824.50
25.75

9.77
18.82
106.16
18.82
12.36
18.37
410.35
18.37
17.62
21.84
167.35
22.39
34.33
22.39
549.02
27.10
107.58
26.01
109.30
26.01
895.65
26.01
63.33
23.89
139.67
16.90
42.42
20.28
108.53
20.28
33.90
16.74
311.49
81495.55684
3,824.50
21.31

9.77
9.77
12.41
6.10
106.16
106.16
12.41
6.10
12.36
12.36
11.92
5.79
410.35
410.35
11.92
5.79
17.62
17.62
13.62
6.91
167.35
167.35
14.30
6.98
34.33
34.33
14.30
6.98
549.02
549.02
19.80
10.48
107.58
107.58
18.47
9.50
109.30
109.30
18.47
9.50
895.65
895.65
18.47
9.50
63.33
63.33
16.13
8.00
139.67
139.67
10.80
5.20
42.42
42.42
15.76
11.83
108.53
108.53
15.76
11.83
33.90
33.90
15.06
13.39
311.49
311.49
56503.456 30916.551
3,824.50
3,824.50
14.77
8.08

9.77
9.77
1.01
-1.49
106.16
106.16
1.01
-1.49
12.36
12.36
0.68
-1.86
410.35
410.35
0.68
-1.86
17.62
17.62
1.51
-0.51
167.35
167.35
1.54
-0.80
34.33
34.33
1.54
-0.80
549.02
549.02
5.03
3.00
107.58
107.58
4.05
1.93
109.30
109.30
4.05
1.93
895.65
895.65
4.05
1.93
63.33
63.33
2.47
0.18
139.67
139.67
0.20
-2.40
42.42
42.42
8.30
6.71
108.53
108.53
8.30
6.71
33.90
33.90
11.55
10.34
311.49
311.49
12378.232 4170.259
3,824.50
3,824.50
3.24
1.09

9.77
1.25
106.16
1.25
12.36
0.82
410.35
0.82
17.62
2.21
167.35
2.66
34.33
2.66
549.02
7.51
107.58
6.31
109.30
6.31
895.65
6.31
63.33
4.26
139.67
-0.10
42.42
7.87
108.53
7.87
33.90
10.13
311.49
15652.507
3,824.50
4.09

TEMPERATURA EXTERIORA DE REFERINTA - teR, cf. rel (9) din NP 048

t eR

luna
SE/ R med
B1
fta
na
V

SE

R 0.33 B1 f ta na V t ev 0.33 na V t e


SE
0.33 B1 na V
R

august
3,824.50
1.182
1.107
0.5
9944.3

septembr.
3,824.50
1.182
1.107
0.5
9944.3

octombr.
3,824.50
1.182
1.107
0.5
9944.3

noiembr.
3,824.50
1.182
1.107
0.5
9944.3

decembr.
ian.
3,824.50
3,824.50
1.182
1.182
1.107
1.107
0.5
0.5
9944.3
9944.3

febr.
3,824.50
1.182
1.107
0.5
9944.3

tev
te
teR

25.75
21.20
23.67

21.31
16.90
19.41

14.77
10.80
13.19

8.08
5.20
7.01

3.24
0.20
2.28

1.09
-2.40
0.06

4.09
-0.10
2.77

CALCULUL Ngz - metoda analitica - cap. 3.1.1 / NP 048, la care se adauga corectia datorata incalzirii cu intermitenta (c

luna
tiR
teR
tiR - teR

august
16.74
23.67
-6.93

Dz(k)

septembr.
octombr. noiembr. decembr.
ian.
febr.
16.74
16.74
16.74
16.74
16.74
16.74
19.41
13.19
7.01
2.28
0.06
2.77
-2.67
3.55
9.73
14.46
16.68
13.97
Z(0)
Z(1)

[
tiR > teR
Dz(0)=0
Dz(1)=31
Dz(2)=30 Dz(3)=31
Dz(4) =31 Dz(5)=28

Ngz(k)

110.05

291.9

Dz1 = 0.5* tiR - teR (1)


teR (0) - teR(1)

*[ Z(0) + Z(1)]

DzL = 0.5* tiR - teR (L)


teR (L+1) - teR(L)

*[ Z(L) + Z(L+1)] =

Dz0 = 0
Dz(L+1) = 0

448.26

517.08

391.16

17.41

tiR (1)>teR (1)

14.32

tiR (L)>teR (L)

DzL<0.5*Z(1)
, pt DzL<0.5*Z(L)

k=L+1

Dz =

Dz(k) = Dz(0) + Dz(1) +..Dz(L) + Dz(L+1) = 212


k=0

Ngz (k) = Dz(k)* [ tiR - teR(k)], in care k=1,.., L


Ngz (k) =
2128.16
NUMARUL CORECTAT DE GRADE-ZILE "Ngz" - pt incalzirea cu intermitenta
Ngz = [(k)*Ngz(k)]

in care: (k)

f + a(k)*0(k) + G(k)*(k)
P
0(k) =

Qo
Q inc(k)

f = 8

Q o = 60.8+219.3 = 280.1 kW = 280100 W


Q inc(k) = ( SE/Rmed + 0.33*B1*na*V)*C*[tiR - teR(k)]

luna
SE/ R med
B1
na

august
3,824.50
1.182
0.5

septembr.
3,824.50
1.182
0.5

octombr.
3,824.50
1.182
0.5

noiembr.
3,824.50
1.182
0.5

decembr.
ian.
3,824.50
3,824.50
1.182
1.182
0.5
0.5

febr.
3,824.50
1.182
0.5

V
C
tiR
teR
Q inc(k)
Qo
o (k)

9944.3
0.892
16.74
23.67

9944.3
0.892
16.74
19.41

9944.3
0.892
16.74
13.19

9944.3
0.892
16.74
7.01

9944.3
0.892
16.74
2.28

9944.3
0.892
16.74
0.06

9944.3
0.892
16.74
2.77

-35630.1
280100
-7.86

-13727.62
280100
-20.40

18252.08
280100
15.35

50026.13
280100
5.60

74345.10
280100
3.77

85759.08
280100
3.27

71825.80
280100
3.90

0.892

1965.23

Consumul anual de caldura al cladirii de referinta - rel. 1 NP 048


an
Q inc =

0.024* (SE/R med + 0.33* B 1*na *V) * C * Ngz =


0.024

an
Q Sinc =

3824.5

0.33

1.182

an
an
Q inc + Q cs
inc

0.5

9944.3

an
Qcs = 0

inc = r * d * g =

0.873

r=
0.99
d=
1
g = o * ( go - v) =

an
Q Sinc =

242498.30

an
Q inc
inc

o = 0.98
go = 0.92
v = 0.02

0.882

277775.83

kWh/an

84.33

kWh/mp,an

Consumul specific de caldura anual


an
q inc =

an
Q inc
Sinc

=>

CLASA B

an
q Sinc =

an
Q Sinc
=
96.60
kWh/mp,an
Sinc
Consumul anual pt prepararea apei calde de consum - cladirea de referinta
Qacc=1068*Np=
qacc =

416520

kWh/an

1068*Np*40/(24*7) =
S inc

34.48 kWh/mp, an

=>

Consumul anual de energie electrica pt iluminat - cladirea de referinta


W ilum = 6*Sinc + tu*Pn =

122253.48 kWh/an

CLASA B

tu =( tD*FD*FO) + tN*FO =
Pn =
42
S inc =
2875.58

2500 h
kW
mp

q ilum = Wilum / Sinc =

42.52 kWh/mp,an

=>

CLASA B

Consumul anual de energie electrica pt climatizare - cladirea de referinta


qclim =

62.18 kWh/mp,an

=>

CLASA C

Consumul anual specific de energie al cladirii de referinta


qT = qinc + qacc + qil + qclim =

223.51

kWh/mp,an

CLASA B

Emisia de CO2 - cladirea de referinta

E co2 = Q Sinc*fh,co2 + Qacc*fw,co2 + Qclim*fclim,co2 + Qil*fil, co2


fh,CO2 = 0.205
fw,CO2 = 0.09
fclim,co2 = 0.09
fil,co2 = 0.09

[kg / kWh]
[kg / kWh]
[kg / kWh]
[kg / kWh]

[kg CO2 /an]

cf. tab. 1.13 si 1.14

Indicele de emisie echivalent CO2

Ico2 =

E co2
S inc

29.79

[kg CO2 / mp, an]

I co2 = qinc*fj,CO2 + qacc*fw,CO2 + qil*fi,CO2 + q clim*fCO2 =

29.79

84.33*0.205 +34.48*0.09 + 42.52*0.09 + 62.18*0.09 =

17.28 + 3.10 + 3.82 + 5.59 = 29.79

Notarea energetica a cladirii de referinta

exp B1 qT po B2 ,
N

100,

pentru
pentru

qT po qTm kWh / m2 an
qT po qTm kWh / m2an

po = p1*p2*.p12 = 1
Cazul 2 -

caz
1
2
3

Utilitati:

B1
0.001053
0.000761
0.001016

- incalzire
- apa calda de consum
- iluminat
- climatizare
B2
4.73677
4.71556
4.73724

qTm
125
145
130

qTM
820
1120
850

0.000742

N = 94.20

4.71646

pentru ca

150

1150

qT*1>qTm kWh/Mp, an
(223.51>145)

TEMPERATURA EXT. ECHIVALENTA CARACTERISTICA PERETELUI EXT.OPAC


R1'min= 1.25 (pereti), R2'min = 3.2 (terasa)
e = 17, abs = 0.4 (pereti) sau 0.8 (terasa)

t E pe j

abs
cs I T 1 cs
e
j

I t
dif

NORD
abs
august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

e
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

17
17
17
17
17
17
17
17
17
17
17
17

abs/ e csn
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala N
I dif. Vert.
73.7
51.2
25.2
15.3
11.7
13.6
20.7
30
39.6
65.9
76.9
70.1

45
35.6
25.2
15.3
11.7
13.6
20.7
30
39.6
46.9
50.3
48.2

17
17
17
17
17
17
17
17
17
17
17
17

abs/ e csn
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I tot N-V
I dif. Vert.
75.8
60.1
36.3
16.5
12.3
14.9
28
38.9
52.8
70.4
78.2
71.1

45
35.6
25.2
15.3
11.7
13.6
20.7
30
39.6
46.9
50.3
48.2

N-V
abs
august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

e
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

SUD
abs

17
17
17
17
17
17
17
17
17
17
17
17

abs/ e csn
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala S
I dif. Vert.
138.1
136.8
125.7
73.3
68.9
76.7
106.9
103.5
94.8
91.6
96.8
94.9

45
35.6
25.2
15.3
11.7
13.6
20.7
30
39.6
46.9
50.3
48.2

17
17
17
17
17
17
17
17
17
17
17
17

abs/ e csn
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

I totala SV I dif. Vert.


123.8
119.1
104.1
57.4
53
59.3
87.3
91.4
91.6
86
92.8
89.9

45
35.6
25.2
15.3
11.7
13.6
20.7
30
39.6
46.9
50.3
48.2

TERASA / ZONA JARDINIERE PARTER (Z1)


abs
e
abs/ e cso
august
0.8
17
0.0471
septembrie
0.8
17
0.0471
octombrie
0.8
17
0.0471
noiembrie
0.8
17
0.0471
decembrie
0.8
17
0.0471
ianuarie
0.8
17
0.0471
februarie
0.8
17
0.0471
martie
0.8
17
0.0471
aprilie
0.8
17
0.0471
mai
0.8
17
0.0471
iunie
0.8
17
0.0471
iulie
0.8
17
0.0471

0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

e
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

SUD-VEST
abs
august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

e
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

I tot.oriz

I dif. oriz.

49.6
85
124.8
167.2
205.6
233.5
200.8
233.2
175.5
114.2
54.2
41.3

27.1
41.4
60
79.2
93.9
100.7
96.3
90.1
71.1
50.4
30.6
23.5

EST
abs

abs/ e csn

I totala E

I dif. Vert.

august
septembrie
octombrie
noiembrie
decembrie
ianuarie
februarie
martie
aprilie
mai
iunie
iulie

0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

17
17
17
17
17
17
17
17
17
17
17
17

0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235
0.0235

0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55

78
84.6
66
33
27.3
30.9
53.9
65.9
76
74.9
79.6
72.2

45
35.6
25.2
15.3
11.7
13.6
20.7
30
39.6
46.9
50.3
48.2

pereti
F1, F2
pt. denumirea peretilor vezi pg de rezistente termice
273.44
71.96
37.97
250.84
F.O. = pereti fara orientare
148.15
432.13
295.12
46.26
0
27.23
534.96
60.06
12.64
18.24
347.29
327.06
58.54
35.6
4.7
5.04
3.2
1.05
1.05
1.05
1.05
1.25
108.53
311.49
55.75
33.90
4.48
4.03
3824.50
terasa
subsol 1 A2-peste parter A1
A3
Usi metalice
0.843

martie
5.51
139.22
5.51
8.38
5.51
71.15
4.80
10.11
4.80
132.61
17.03
23.24
5.62
22.62
5.62
7.75
6.46
226.33
6.46

aprilie
12.23
139.22
12.23
8.38
12.23
71.15
11.30
10.11
11.30
132.61
18.13
23.24
12.40
22.62
12.40
7.75
12.95
226.33
12.95

mai
18.05
139.22
18.05
8.38
18.05
71.15
16.70
10.11
16.70
132.61
19.09
23.24
18.11
22.62
18.11
7.75
18.38
226.33
18.38

iunie
21.73
139.22
21.73
8.38
21.73
71.15
20.20
10.11
20.20
132.61
19.71
23.24
21.74
22.62
21.74
7.75
21.99
226.33
21.99

iulie
23.42
139.22
23.42
8.38
23.42
71.15
22.00
10.11
22.00
132.61
20.06
23.24
23.43
22.62
23.43
7.75
23.74
226.33
23.74

august

septembr.

4950.35776 3924.41088

octombr.

2491.58528

3489.302

2858.8732

1963.8792

688.32016

548.2507

350.4698

9.77
9.77
6.30
12.90
106.16
106.16
6.30
12.90
12.36
12.36
5.97
12.70
410.35
410.35
5.97
12.70
17.62
17.62
8.15
15.73
167.35
167.35
8.70
16.54
34.33
34.33
8.70
16.54
549.02
549.02
12.67
19.12
107.58
107.58
11.93
18.92
109.30
109.30
11.93
18.92
895.65
895.65
11.93
18.92
63.33
63.33
10.36
17.97
139.67
139.67
4.80
11.30
42.42
42.42
13.75
18.08
108.53
108.53
13.75
18.08
33.90
33.90
11.45
13.03
311.49
311.49
35005.94
59280.5
3,824.50 3,824.50
9.15
15.50

9.77
9.77
9.77
18.31
21.93
23.67
106.16
106.16
106.16
18.31
21.93
23.67
12.36
12.36
12.36
18.17
21.76
23.44
410.35
410.35
410.35
18.17
21.76
23.44
17.62
17.62
17.62
23.11
27.46
28.74
167.35
167.35
167.35
23.39
27.54
28.80
34.33
34.33
34.33
23.39
27.54
28.80
549.02
549.02
549.02
24.69
28.68
30.26
107.58
107.58
107.58
24.35
28.44
29.95
109.30
109.30
109.30
24.35
28.44
29.95
895.65
895.65
895.65
24.35
28.44
29.95
63.33
63.33
63.33
23.67
27.63
28.86
139.67
139.67
139.67
16.70
20.20
22.00
42.42
42.42
42.42
21.17
22.42
23.69
108.53
108.53
108.53
21.17
22.42
23.69
33.90
33.90
33.90
14.91
16.25
17.26
311.49
311.49
311.49
79466.1291 92957.47 98457.85
3,824.50
3,824.50 3,824.50
20.78
24.31
25.74

5538.81216

4497.705

2996.109

2759.1456

2230.5464

1470.8332

9710.59392 7861.84564

5101.4024

4685.76744

3654.924

2279.307

965.235349

768.6487

490.919

15438.4424 12292.5578

7850.986

3438.3014

2915.418

2130.084

3397.11628

2842.893

2018.771

27836.8381 23295.8565

16542.6555

1968.15907

1647.2133

1169.7051

3947.19907

3336.7163

2252.8771

899.274419 716.874419

458.136

2520.02306

2200.9884

1710.4328

787.268571

687.492

534.264

5479.03371

5214.3426

4691.0394

98499.1905 81495.5568

56503.45578

TEMPERATURA INTERIOARA REDUSA - cf.

martie
aprilie
3,824.50 3,824.50
1.182
1.182
1.107
1.107
0.5
0.5
9944.3
9944.3

mai
iunie
iulie
3,824.50
3,824.50 3,824.50
1.182
1.182
1.182
1.107
1.107
1.107
0.5
0.5
0.5
9944.3
9944.3
9944.3

ti R ti a

luna
S inc

august
2875.58

SE

9.15
4.80
7.63

15.50
11.30
13.83

20.78
16.70
18.99

24.31
29.30
24.99

25.75
30.50
26.32

iunie
16.74
24.99
-8.25

iulie
16.74
26.32
-9.58

a incalzirii cu intermitenta (cap. 3.1.3 / NP 048)

martie
16.74
7.63
9.11

Dz(6)=31

aprilie
16.74
13.83
2.91
Z(L)
]
Dz(7)=30

282.41

mai
16.74
18.99
-2.25
Z(L+1)

B1
na
V
SE/ R med
ti med
a
tiR

1.182
0.5
9944.3
3,824.50
19.57
5.68
16.74

87.3

Dz1 = 31

(oct.)

DzL = 31

(aprilie)

NGZ corectat pentru incalzirea cu intermiten


P = 24
TiR (k) =

tiR - teR (k)


ti med - teR (k)

(k)

tiG - teR (k)


ti med - teR (k)

V)*C*[tiR - teR(k)]

martie
aprilie
3,824.50 3,824.50
1.182
1.182
0.5
0.5

mai
iunie
iulie
3,824.50
3,824.50 3,824.50
1.182
1.182
1.182
0.5
0.5
0.5

9944.3
0.892
16.74
7.63

9944.3
0.892
16.74
13.83

9944.3
0.892
16.74
18.99

9944.3
0.892
16.74
24.99

9944.3
0.892
16.74
26.32

46838.44
280100
5.98

14961.57
280100
18.72

-11568.22
280100
-24.21

-42416.8
280100
-6.60

-49254.9
280100
-5.69

242498.3

luna
tiR
teR
ti med
ti - teR
TiR(k)
tiG
(k)
o (k)
E
termen B
termen 1
Tc
a(k)
G(k)
(k)
Ngz(k)

august
16.74
23.67
19.57
-4.1
1.690
12
2.85
-7.86
0.43
0.383
22.10
18.88
0.000
-

NGZ = [ (k) * Ngz(k)] =

Determinarea a(k) si G(k) prin verificarea ineg


teR(k) +[ti - teR(K)]*

teR(k)+[ti - teR(k)] ]*
[

Determinarea coeficientului de corectie a necesar


(k)

f + a(k)

te

tEpe j,n
21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

te

22.63
17.94
11.39
5.56
0.48
-2.08
0.39
5.51
12.23
18.05
21.73
23.42

tEpe j,n
21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

22.66
18.05
11.54
5.58
0.48
-2.06
0.48
5.62
12.40
18.11
21.74
23.43

te

tEpe j,n
21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

te

23.46
19.05
12.69
6.31
1.22
-1.26
1.50
6.46
12.95
18.38
21.99
23.74

t Epe j,n
21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

te

23.28
18.82
12.41
6.10
1.01
-1.49
1.25
6.30
12.90
18.31
21.93
23.67

t Epe j,n
21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

te

23.22
20.28
15.76
11.83
8.30
6.71
7.87
13.75
18.08
21.17
22.42
23.69

t Epe j,n

21.2
16.9
10.8
5.2
0.2
-2.4
-0.1
4.8
11.3
16.7
20.2
22

noiembr.

22.69
18.37
11.92
5.79
0.68
-1.86
0.82
5.97
12.70
18.17
21.76
23.44

decembr.

ian.

febr.

martie

aprilie

mai

iunie

iulie

1216.26112

105.00096

-455.004 85.31328 1205.324 2675.337 3948.474 4753.481 5123.172

1142.1044

407.8208

25.5936 361.9836 1080.833 2034.077 2827.076 3341.004 3606.034

169.4646

14.5776

-62.5622

14.5776 170.6794

376.588 550.0007 660.2438 711.5691

1489.791

288.042

-297.486

354.15 1525.206 3057.495 4339.518 5191.839 5605.014

722.972

119.7052

-176.595

148.15

2477.9463

291.0196

-796.024 350.9354 2554.981 5435.219 7776.215 9312.627 10031.62

1156.3885

252.6985

-85.3485 369.8435 1363.903 2632.416 3867.459 4595.431 4809.639

239.6234

52.8682

3832.1596

845.4908

1127.4384

541.1274

1038.35

442.665

8508.675

-27.464

91.3178

746.676 1528.908 2170.101 2599.144 2805.368

298.671 567.8182 802.9787 945.4482

988.704

-439.216 1460.393 4776.474 9080.791 12841.58 15120.01 15811.78


322.74 807.9258 1363.039
210.949

2056.93

2656.15 3085.394 3255.371

689.683 1303.949 2067.956 2661.455 3108.492 3273.535

3627.3825 1728.605 5651.552

10685.1

16945.7 21809.08 25472.29 26824.72

601.635

256.4865 122.2269 399.6123 755.5269 1198.204 1542.086 1801.105 1896.734

1117.36

344.9849

220.584

8.484

1283.9099
401.037
4170.8511

30916.55132

25.1406 594.9942 1446.981


-101.808

-4.242

203.616

2509.87 3305.989 3859.082 4030.876


479.346

900.799 728.2363 854.1311 1492.288 1962.222


281.37

227.469

266.793

466.125

612.912

708.414

856.884

933.24

2297.58 2433.243 2571.076


717.663

760.038

803.091

3597.7095 3220.807 3155.394 3566.561 4058.715 4644.316 5061.713 5376.317

12378.23246 4170.259 15652.51 35005.94

59280.5 79466.13 92957.47 98457.85

ERIOARA REDUSA - cf. rel. (8) din NP 048

ti a

S inc
SE
0,33 B1 na V
R
septembr.
2875.58

octombr.
noiembr. decembr.
2875.58 2875.58 2875.58

ian.
2875.58

febr.
2875.58

martie
2875.58

aprilie
2875.58

mai
2875.58

1.182
0.5
9944.3
3,824.50
19.57
5.68
16.74

1.182
1.182
1.182
1.182
1.182
1.182
1.182
1.182
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
9944.3
3,824.50
3,824.50 3,824.50 3,824.50 3,824.50 3,824.50 3,824.50 3,824.50
19.57
19.57
19.57
19.57
19.57
19.57
19.57
19.57
5.68
5.68
5.68
5.68
5.68
5.68
5.68
5.68
16.74
16.74
16.74
16.74
16.74
16.74
16.74
16.74

incalzirea cu intermitenta

tiG = 12 C

septembr.
16.74
19.41
19.57
0.16
-16.688
12
-46.31
-20.40
0.43
0.806
19.54
18.88
0.000
-

octombr.
noiembr. decembr.
16.74
16.74
16.74
13.19
7.01
2.28
19.57
19.57
19.57
6.38
12.56
17.29
0.556
0.775
0.836
12
12
12
-0.19
0.40
0.56
15.35
5.60
3.77
0.43
0.43
0.43
0.439
0.467
0.492
15.99
12.87
10.79
18.88
18.88
18.88
1.304
2.659
3.495
0
0
1.631
1.167
0.954
0.882
110.05
291.9
448.26

ian.
16.74
0.06
19.57
19.51
0.855
12
0.61
3.27
0.43
0.505
9.92
18.88
3.694
3.036
0.837
517.08

febr.
16.74
2.77
19.57
16.8
0.832
12
0.55
3.90
0.43
0.489
10.99
18.88
3.456
1.236
0.895
391.16

martie
16.74
7.63
19.57
11.94
0.763
12
0.37
5.98
0.43
0.464
13.17
18.88
2.520
0
0.961
282.41

aprilie
16.74
13.83
19.57
5.74
0.507
12
-0.32
18.72
0.43
0.000
13.83
18.88
1.169
0
1.245
87.30

mai
16.74
18.99
19.57
0.58
-3.879
12
-12.05
-24.21
0.43
0.473
19.26
18.88
-

1965.23

G(k) prin verificarea inegalitatii :

[ti - teR(K)]*

E
1+(E-1)/o(k) *TiR(k)

> tiG

Inegalitatea se verifica
pt lunile oct., nov., martie, aprilie, deci:
a(k) = -Tc*ln{1+(E-1)/ o (k)*TiR(k)}
G(k) = 0

*[

termen

termen 1

]
]

Pt lunile dec. , ian., feb.


inegalitatea nu se verifica, deci:

a(k) = -Tc*ln{[1- o (k)*TiR(k)]/[ (k) - o (k)*TiR


G(k) = p - f + Tc*ln[ (k)] - a(k)

ntului de corectie a necesarului de caldura (k)


(k)

f + a(k) * o (k) + G(k)* (k)


P

f =
P =

8 8
24

iunie
2875.58

iulie
2875.58

1.182
1.182
0.5
0.5
9944.3
9944.3
3,824.50 3,824.50
19.57
19.57
5.68
5.68
16.74
16.74

iunie
16.74
24.99
19.57
-5.42
1.522
12
2.40
-6.60
0.43
0.380
22.93
18.88

iulie
16.74
26.32
19.57
-6.75
1.419
12
2.12
-5.69
0.43
0.376
23.78
18.88

)/ o (k)*TiR(k)}

k)*TiR(k)]/[ (k) - o (k)*TiR(k)]}