Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
V.2.5(Complete)
For:ENTELUMTSProject InstallationTeams
Ing.RodrigoRosa AfterSalesDepartment ZTEBoliviaS.R.L
CONTENTS
IntroductiontoZTEZXSDR p Engineeringpreparation p BBUInstallation
p
p p p p p
RRUandOLPinstallation
p p
AntennaInstallation
2006,ZTECorporation.Allrightsreserved.
IntroductiontoZTEZXSDR
TheSoftwareDefinedRadioBaseStations(SDR)adoptinnovativedistributed structure,unifiedMicroTCAplatform,andmulticarriertechnologiesto significantlyboostsystemintegrationandefficiency,aswellasnetwork convergenceandevolutioncapabilities.ZXSDRseriesbasestationssupport multimode,multibandwirelessoperationthroughsoftwareconfiguration. AllowspowerfulevolutiontoLTE. Itconsistsoftwoparts:BBUandRRU/RSU,whichcanbeusedeitherindoors oroutdoors.Suchdistributedbasestationarchitectureallowsflexiblesite selection,zerofootprint,extendedcoverage,andbasebandpoolin hightrafficscenarios. ZXSDRBS8700/BS8900allowsdualmodeGSM+ UMTSservicedeployment
2006,ZTECorporation.Allrightsreserved.
ConceptsAboutDistributedBaseStation
n n n
Iub
I ub
TRX
( BBU)
( RRU)
2006,ZTECorporation.Allrightsreserved.
EquipmentStructureandTopology
2006,ZTECorporation.Allrightsreserved.
TypicalApplication
2006,ZTECorporation.Allrightsreserved.
BaseBandUnitZXSDRB8200
PerformanceIndex
19inch 2U
482.6mm
n
ProcessingCapability:
u UMTS:30CS(6CS*5BPCs) u GSM:60TRX
88.4mm
n
BaseBandProcessingCapability:
u Uplink/Downlink:960CE
DataProcessingCapability:
u Downlink:216Mbps u Uplink:75Mbps
PhysicalIndex
n n n
BPCProcessing Capability
InterfaceIndex InterfaceIndex
n
Abis/IubInterface:
u 2*STM116*E1/T11*FE/GE n n n
Electric/Optical(8VLAN)
n
ToRRU:12*1.25GbpsCPRIopticalinterface
2006,ZTECorporation.Allrightsreserved.
RemoteRadioUnitZXSDRR8860
PerformanceIndex
n CarrierConfiguration: u Supportmaximal:6TRXor4CS u Supportmaximal:4G1U n OutputPower80W n ReceiveSensitivity:113dBm[GSM]
370mm
320mm
SupportGSMandUMTS.
InterfaceIndex
n
19
2*1.25GCPRIOpticalinterface
m 7m
ZXSDRR88601T2R
PhysicalIndex PhysicalIndex
n Volume:370320197mmHW D n Weight:20Kg n TPC:UMTS:1C:155W/2C:185W/3C:210W/4C:230W
GSM:200W(900M)/210W(1800M) GU:4G1U215W
n PowerSupply:48VDC n TemperatureRange:40+55 n ProtectionClass:IP65
2006,ZTECorporation.Allrightsreserved.
EngineeringPreparations
n
Environment
l
l l l l
Allcivilworksoftheequipmentroomshouldhavebeencompleted. Including:towerandmonopoles,concretebases,equipmentrooms, paintingjobs,cablingladders,engineeringholesandtroughs, commercialACinput,lightingsystems,etc. Thewallsindoorsshouldbedryenoughcoatedwithfireretardant whitelusterlesspaintorotherfireretardantmaterials. Indoorenvironmenttemperature:25~55Recommended constanttemperature:10~50. Relativehumidity:5%~100%recommendedconstanttemperature: 5%~95%. Illuminationofequipmentroomshouldincludethreecompletesetsof illuminatingsystems:dailyillumination,standbyilluminationand emergencyillumination.Avoidthedirectexposuretosunlight. Outdoorenvironmenttemperature:40~55. Relativehumidity:10%~100%. Safelightningprotectionmeasuresshouldbeadopted Groundingsystemshouldmeetrelevantrequirement.
2006,ZTECorporation.Allrightsreserved.
Flatsteel
Verticalgroundingbody
Tower groundingnet
Equipment groundingnet
Transformer groundingnet
2006,ZTECorporation.Allrightsreserved.
l l
2006,ZTECorporation.Allrightsreserved.
Specialrequirementsforequipmentrooms
n n n n
n n
Thedoorheight2m,passage1m,ceilingheight3m. Distancefromfaceofcabinettootherequipment80cm. Recommendeddistancebetween2rowsofequipments1meter. 2 Roomfloorandrooftopsurfacsshouldsustainatleast450kg/m . Whensupplyincludesbigstoragebatteries,floorshouldsustainat 2 least800kg/m . 2 ofthefloor2mm. Heightdeviationforevery1m Environmentfreefromhightemperature,condenseddust,mephitis, explosivearticlesandlowatmosphericpressure. Checklocationofthefeederwindow.Ifnofeederwindow,selecta properplacein,avoidopeningitinthebearingstrutorthedownlead ofthelightningarrester.
2006,ZTECorporation.Allrightsreserved.
Power
n
1.ACpowersupply Threephasepowersupply:380V10%,50Hz5%. Singlephaseordoublephasepowersupply:220V10%, 50Hz5%. 2.DCpowersupply Nominalvoltage:48V,allowing57V~40V DCpowersupplyshouldhaveprotectionandindicationforover currentandovervoltage. 3.UPSRequirements InputVoltage(V):220V10%. InputFrequency(Hz):50Hz5%. OutputVoltage(V):220V3%~220V5%. OutputFrequency(Hz):50Hz~60Hz. OutputWave:Sinewave Working:Online DynamicReactionTime:Shorterthan2ms
2006,ZTECorporation.Allrightsreserved.
Transmission:
n n
Transmittingequipmentisinstalledproperlyandworksnormally DDForrouterisfixedandconnectedwiththetransmitting equipment. Ifthetransmissionmediumismicrowave,parametersoftheIP addressescarefullyplanned. Antenna,feedercableandtoweroftheBTSsystemandthe equipmentshouldbewellgroundedgroundingresistanceshouldbe lessthan10. Antennacanbeinstalledontheroofwithorwithoutenclosure,oron atowerorapole.Beforetheformalinstallationoftheantenna. supportsandpolesshouldbewellfixedandthetower,pole,cabling rackshouldbechecked. Heightandstrengthofthetowerconformtothespecifications. Groundingcopperbararoundthetowerproperlyinstalled. Platformofthetowerproperlyinstalled.
Antennaandfeeders
n
n n n
2006,ZTECorporation.Allrightsreserved.
n n n n n
n n
RooftopPolesforfixingBTSantennashouldbeverticaltothe horizontalplaneandtheerrorshouldnotexceed1. Poleshouldbeinstalledneartheedgeofthebuildingtoptothe extentpossible. Polesdirectlyfixedontherooftopmustusecementpier,insteadof directlypunchingonthebuildingroof. Cablingrackmustnotshake. Indoorcablingrackshouldbegroundedonetimeevery5m Transportaccessshouldbeclearofobstacles Temporarystoringenvironment Shouldhaveexcellentpackaging,waterproofandshockresistant conditionsfreeoffire,theft,hightemperature,rodents,corrosion, electromagneticinterference.Andconsiderlightningprotectionand poisonprotectionmeasures. Intensityoftheelectricfield300mV/m Intensityofthemagneticfield11Gs.
2006,ZTECorporation.Allrightsreserved.
Installation Elements
2006,ZTECorporation.Allrightsreserved.
BBUInstallation
n
Elementstobeinstalled
2006,ZTECorporation.Allrightsreserved.
2006,ZTECorporation.Allrightsreserved.
InstallationofB8900usingoutdoorcabinet
n
TherearefourcombinationsoftheZXSDRBS8900:
l l l l
2006,ZTECorporation.Allrightsreserved.
InstallationFlow
Start
Preparation
Installingacabinet
Installingthemodulesinacabinet
Installingcables
Waterprooftreatment
End
2006,ZTECorporation.Allrightsreserved.
SpaceRequirement
2006,ZTECorporation.Allrightsreserved.
n
1.
GroundInstallation
Determineinstallationposition.Drawtwostraightlinesparalleltothe datumline.Determinepositionoftheinstallationholesforthecabineton thetwolines.Followingfigureshowstheinstallationposition
2.
Drillholesforexpanssionbolts,10mmor(dependingonthesupply), 90mmdepth
2006,ZTECorporation.Allrightsreserved.
3.
2006,ZTECorporation.Allrightsreserved.
4. Ifsiteislocatedinarooftopterracewithouteasyaccessusingstairsor
5. 6.
Openthefrontdoor,andremovetheboltsofthewoodenpallet. Demountthereardoorpanel,andremovetheboltsofthewoodenpallet.
2006,ZTECorporation.Allrightsreserved.
7. 8.
2006,ZTECorporation.Allrightsreserved.
9.
Alt.BIfcabinetincludesabase fixedtothebottomofthecabinet: PutthePC8910cabinetinposition, andfixthecabinetontheground throughanexpansionboltsuite.If necessary,levelthebaseusing metallevelingwashers NOTE: Inactiveseismicareas,mounting forceappliedtonutsshouldbeup to45Nm.Otherwisemounting forceshouldbeenoughtoensure thecabinetdoesntshakes
2006,ZTECorporation.Allrightsreserved.
10.
2006,ZTECorporation.Allrightsreserved.
11.
12.
FixthecabinetroofontopofBC8910 cabinet
2006,ZTECorporation.Allrightsreserved.
2006,ZTECorporation.Allrightsreserved.
BC8910CabinetLayout
Climateconditioner (Fan/Heater)
Cooling/Heating ControlPanel
Availableexpansion space(4U)
ACbreakers
ILP
RectifierModules
ZXDU58B121 Powersolution
RectifierControlModule
2006,ZTECorporation.Allrightsreserved.
InstallationofIndoorBBU
n
2006,ZTECorporation.Allrightsreserved.
7 6 5 4 3 2 1 No.
2 8 8 4 4 2 2 Quantity
Remarks
2006,ZTECorporation.Allrightsreserved.
InstallationFlow
Start
Installationpreparation
Installcabinet
Installmodulesinsidethecabinet
Installcables
End
2006,ZTECorporation.Allrightsreserved.
Checkanddetermineifcurrent 19locationsatisfiesthe installationrequirements. n Insetthefloatingnutintothe mountingholesinthevacant5U slotinthemountingbracket accordingtothelocationofthe ZXSDRB8200equipmentandthe wiringtrough n Carefullyinsertthewiretrough intothe1Uspacecorresponding tothefloatingnut,andfastenthe screw n InstalltheB8200equipment abovethewiretrough.Checkthe stabilityofB8200.Itshouldnot shakewithhandshaking.
n
2006,ZTECorporation.Allrightsreserved.
Warning
BecarefullwithventillationandairflowwheninstallingZXSDR B8200indoor,orthepurityofaircannotcomplyrequirements, causingfanairintakejamandraisingtemperatureinZXSDR B8200,causingovertemperaturealarm,anddamagingtheBBU. n Radiatingheatrequirements:Aminimumof40mmventilation spaceshouldbereservedboththeleft/rightsidesoftheZXSDR BS8700cabinet.Theairinletisattherightsideandtheairoutlet isattheleftside.Noheatsourceshouldbelocatedtotheright sideoftheZXSDRB8200cabinet.Ifthereis,ZXSDRB8200 shouldbeinstalledinotherplace.
n
2006,ZTECorporation.Allrightsreserved.
ModuleInstallation
ControlandclockmoduleCCisinstalledinslot1andslot2.itsupportsoneor twoCC FabricswitchmoduleFSisinstalledinslot3andslot4.itsupportsoneortwo FS.WhenusesoneFS,slot4canbeusedtoconfigureTAM,BPC,orUBPG. SitealarmextenderboardSEisinstalledinslot5.ItcanhaveoneSEornoSE. IfnoSE,slot5canbeusedtoconfigureBPCorUBPG. ToweramplifiermoduleTAMcanbeinstalledinslot4,5,6,7,or8.Usually, TAMisinstalledinslot8first,andthen4.IfnoTAM,slot4,5,6,7,and8can beusedtoconfigureBPCorUBPG. BasebandprocessingboardBPC/UBPGcanbeinstalledinslots4,5,6,7,8. SitealarmmoduleSAisinstalledinslot13. PowermodulePMisinstalledinslot14and15.ItsupportsoneortwoPM.
2006,ZTECorporation.Allrightsreserved.
CableInstallation
n
CablingFlow
CableList
l l l l l l l
2006,ZTECorporation.Allrightsreserved.
CablingPrinciples
l
Iftheequipmentroomisequippedwithracksandantistaticfloorboards, usedownwardcablingmode.Ifupwardcablingmodeisused,needto installacablingrack/cablingladderattheupperpartofthecabinetand routethecablesinthecablingrack. Cablingpositionshouldbedesignedinadvance.Thecablesshouldbe arrangedorderly,andtheirskinshouldnotbedamaged. Externalcablesincludepowercables,tailfibers,trunkcables,andother signalcables.Cablesinthecablingrackshouldbecategorizedand bundled,shouldnotbecrossedeachother.Cablesshouldbefixedby cableties.Bundlingintervalshouldbe20cm. Bendingpositionofeachcableshouldbeevenandsmooth.The minimumbendingradius=60mm. Cablesshouldbebundledorderlyandstraightly.Cabletiesshouldbe distributedatregularintervals,andtightenedmoderately.
2006,ZTECorporation.Allrightsreserved.
Cablesinacablingtroughmaynotbebundled.Cablesinacabling troughshouldbestraight,notcrosseachother,andnotoverflowthe trough.Cablesshouldbebundledattheentranceandexitofthecabling troughandattheturningpositions. Trunkcablesroutedfromthecabinettothecableterminalrackshould notbestrained.Redundantcablesshouldnotbecut.Inacablingtrough orinamovablefloor,cablesleadingtodifferentcabinetsshouldbe bundledseparatelyfromeachother.Cablesshouldbestraightand ordered,notcrosseachother.Theirskinshouldnotbedamaged.If necessary,reserveadditionallengthforthecables. Cableshouldbeaffixedwithcorrespondinglabels.Everylabelshouldbe affixed2cmawayfromoneendofthecable.Labelindicatesthe destinationsofbothends:cabinetnumberplusslotnumberplussocket number. Thecablesshouldberoutedtofacilitatemaintenanceandfuture expansioncapacity.
2006,ZTECorporation.Allrightsreserved.
CableConection(BBU)
2006,ZTECorporation.Allrightsreserved.
DataCableDescription(for indoorinstallations)
EndAisSCSI50plug EndB1isgroundingend EndB2isDB44plug (connectedtoE1/T1) EndB3isRS232/RS485 connectorformonitoring ZXDU58B121power supplyequipment EndB4isdrycontact connector
2006,ZTECorporation.Allrightsreserved.
IncommingcablestoPC8910cabinet
OpticalFibers InstallationCare
Inordertopreventdamagestofibercore,specialcaresmustbepaidto OpticalFiberinstallation:
l l l
l l l
2006,ZTECorporation.Allrightsreserved.
InstallationProcedure
2006,ZTECorporation.Allrightsreserved.
2006,ZTECorporation.Allrightsreserved.
Iftheopticalcables arelaidoutdoors, theyshallbebundled togetherwiththe powercableswith antiultraviolettiesor clamps.Theintervals betweenadjacent ties/clipsshouldbe consistently500mm.
2006,ZTECorporation.Allrightsreserved.
ConnectingOpticalFiberCablesattheRRUSide
2006,ZTECorporation.Allrightsreserved.
2006,ZTECorporation.Allrightsreserved.
2006,ZTECorporation.Allrightsreserved.
2006,ZTECorporation.Allrightsreserved.
PowerCables ColorCodeStandards
DCCableColorcodefor48V:
Function Negative Positive/Neutral/ WorkingGround ProtectiveGround Label ,48V +,N, 48VRTN, GND PE,PGND Color Blue Black
DCCableColorcodeforBatteries:
Function Negative Positive/Neutral/ WorkingGround Label NEG, POS,+ Color Black Red
Yellow/Green
ACCableColorcode(IEC60446/BS7671):
Function ProtectiveGround Neutral Line,singlephase Line,3phase Line,3phase Line,3phase Label PE,PGND N L L1 L2 L3 Color New greenyellow blue brown brown black grey Old greenyellow blue brownorblack brownorblack brownorblack brownorblack
Forsinglephaseinstallationsusing3corecable,usebrown/whitefor phase,blueforneutralandblackforground
2006,ZTECorporation.Allrightsreserved.
PowerCableInstallations(outdoorcabinet)
n
ArrangeDCandACcablesatPC8910cabinettokeepthemsepparated
ACCable
DCCables
2006,ZTECorporation.Allrightsreserved.
CableconnectionsatthePDUofBC8910cabinet
Battery Temperature Sensors(move toPC8910 cabinet)
DCPowercables (blackto+,blueto)
Smoke Sensorcable
ACPower cable
2006,ZTECorporation.Allrightsreserved.
PowerCableconnectionsatthebackofBC8910cabinet(ZXDU58B121 PDU)
2006,ZTECorporation.Allrightsreserved.
PowerBreakersatthefrontofBC8910cabinet(ZXDU58B121)
2006,ZTECorporation.Allrightsreserved.
BatteryInstallationPC8910Cabinet
Connectbatteryrackfancablestothe batteries
2006,ZTECorporation.Allrightsreserved.
Measureoutputpowerwithamultimetertoverifypoweroutput.
2006,ZTECorporation.Allrightsreserved.
Labelcablesandbatteries
2006,ZTECorporation.Allrightsreserved.
2006,ZTECorporation.Allrightsreserved.
IndoorRectifierandBatteryRack
n
EmersonNetsure501A50Rectifier
2006,ZTECorporation.Allrightsreserved.
2006,ZTECorporation.Allrightsreserved.
EmersonRack588820100
2006,ZTECorporation.Allrightsreserved.
2006,ZTECorporation.Allrightsreserved.
IndoorLightningProtectionBox
n
2006,ZTECorporation.Allrightsreserved.
CheckingInstallation
n n n n
n n n n n n
Cabinetinstallationlocationcomplieswiththeengineeringdesign. Cabinetisinstalledinastableandsecuremanner. Cabinetverticaldeviation2mm Cabinetsurfaceiscleanandtidy,withnopaintloss.Ifpaintislost, cabinetmustberepaintedwithadequatepaintforoutdooruse,in thesamecolorofthecabinet. Allscrewsaretightlyscrewed.Theflatwashersorspringwashers areinplace. Allcablesarelaidflatandsmooth. Cablebendingissmooth. Eachcableismarkedcorrectlyandclearly. Cableconnectorsareingoodcontactwiththeinterfaces. Allmetalconnectorsofthepowercableandgroundingcablemust besecuredwithplain/springwashersatthebindingpost.
2006,ZTECorporation.Allrightsreserved.
2006,ZTECorporation.Allrightsreserved.
Engineeringwastesarecleaned.
l
2006,ZTECorporation.Allrightsreserved.
RRU&OLPInstallation
HoistRRUandOLP/LPUtoTower
IfitisrequiredtohoistRRUand/orOLP/LPUtothetowerorabuilding terrace: Naturalconditionsforhoistingoperationaresatisfied,suchasnofog andhighvisibility.Thehoistingoperationisprohibitedinwindy,snowy, orrainydays. Toolsforhoistingoperationareavailable,suchastherope(witha bearingcapacityof100kg)andthecrownblockthecrownblockis firmlyinstalledinappropriatepositiononthetower. Openthepackagetocheckwhetherthecabinetis ingoodcondition. Hoistthecabinettothetoweraftertheinspection:
1. Takeoutthecabinet,makeitsfixingboard upwards,andlayitonthefloor 2. Bindthefixingboardwithrope.Makesurethatthe ropeisboundonthetwofixingboards,andthe bindingisfirm
2006,ZTECorporation.Allrightsreserved.
WARNING
RRUhandlecannotbeusedforbinding thehoistingrope. Itisstrictlyprohibitedtousesteelwirerope asthehoistingrope. Duringhoistingprocedure,irrelevant personisprohibitedtostandsurrounding thetower,especiallyundertheRRU/OLP.
2006,ZTECorporation.Allrightsreserved.
FixRRUtoSupport
NOTE:ENTELrequestsRRUto easilyaccessedformaintenance duties.
1. Installpoleanchorclamp components.
i. Fixanchorclampsontothe pole,andaligntheanchor clampholesandscrewthe boltsabit ii. Adjustthespacebetweenthe clipsbasedonthescrew's positionofsupportingpanel, andfixtheRRUsupporting panelontheclipsatthefront bracketwithM8boltsand tightenitproperly iii. ScrewdownM10boltstightly.
2006,ZTECorporation.Allrightsreserved.
2. MounttheR8860cabinetonthesupportingpanelandfastenthecabinet withfourM6X20hexagonsocketcapscrews
2006,ZTECorporation.Allrightsreserved.
FixOutdoorLightningProtectionUnittoAntennaSupport
2006,ZTECorporation.Allrightsreserved.
OLPwilllaybacktobackwithRRU
OLP Brackets
RRU
2006,ZTECorporation.Allrightsreserved.
RRUSupportPlate
AntennaSupportPole
RRU
OLP
Brackets
OLPSupportPlate
2006,ZTECorporation.Allrightsreserved.
LocationofOLPandRRU(RRU&OLPonSamePoleasAntenna)
2006,ZTECorporation.Allrightsreserved.
LocationofOLPandRRU(RRU&OLPBehindtheAntenna)
2006,ZTECorporation.Allrightsreserved.
LocationofOLPandRRU(RRUonworkingplatform)
2006,ZTECorporation.Allrightsreserved.
CableInstallation
n
CablingFlow
CableList
l l l l
l l
2006,ZTECorporation.Allrightsreserved.
PowerCable OpticalFiberbetweenRRUandBBU
EnvironmentMonitoringCable
RRU
Antenna
AntennaJumper
AISGAntennacontrolcable
2006,ZTECorporation.Allrightsreserved.
ZXSDR8860ERRUinterfaces
2006,ZTECorporation.Allrightsreserved.
CableConection(RRU)
2006,ZTECorporation.Allrightsreserved.
CableConnectionOLPCabling
Grounding cable
Monitoring cable
DCInput (fromrectifier)
DCOutput (toRRU)
2006,ZTECorporation.Allrightsreserved.
CableConnectionMonitoringCableatOLP
NOTE:Useamultimetertoidentifythepair
2006,ZTECorporation.Allrightsreserved.
CableConnectionCableOrder
l
CableGrounding
l
Sector1
Sector2
Sector3
2006,ZTECorporation.Allrightsreserved.
AntennaInstallation
Parameters
n
Height
Theinstallationheightofantennaonthetoweris determinedbynetworkplanningdesign.
Azimuth
Theazimuth/bearingoftheantennaisdeterminedby networkplanningdesign.
Downtilt/Uptilt
Thedowntiltangleoftheantennaisdeterminedby networkplanningdesign.Usuallythemechanical downtiltangleis0~10adjustementprovidedby FastenerB.Aditionaldowntiltisprovidedtrough electricdowntiltmechanismfrom0to8
Direction
Antennadirectiondependsontheantennaazimuth.If twoantennasinsamesector,mustsharethesame azimuth.
2006,ZTECorporation.Allrightsreserved.
Installation
Theantennainstallationpositionmustbeinaccordance withprojectdesign Theantennashouldbehoistedaccordingtosame safetystandardsasRRU Theantennainstallationpositionneedstotake careforlightningprotection.Ifthundersstormdays20 peryearormountainenvironment,protectionangle shouldbe30.Otherwise45arerecommended
1. 2.
Lightingrod 45~30Lightningprotectionarea
3. 4.
Antenna Groundingcable
2006,ZTECorporation.Allrightsreserved.
d0.7mbetweenUMTSand GSM850/1900orDAMPS
d1.4mbetweenUMTSand GSM850/1900orDAMPSantennas.
2006,ZTECorporation.Allrightsreserved.
BecauseWIMAX3.5GandWCDMA850Mareatdifferentfrequencybands,so wedontneedtoconsidertheisolationbetweenthem.
2006,ZTECorporation.Allrightsreserved.
Otherconsiderationsregardingantennaisolation: BacktobackantennasConfrontedantennas
2006,ZTECorporation.Allrightsreserved.
Adjustsupportsalongtheantennabodyaccordingtoantennasupportsize andpreparethejumpers.
2006,ZTECorporation.Allrightsreserved.
2006,ZTECorporation.Allrightsreserved.
Considerthatifthesiterequiresuptilt,theantennabracketsmustbe installedreversed.
Downtiltmounting
Uptiltmounting
2006,ZTECorporation.Allrightsreserved.
ElectricDowntilt AdjustmentMechanism
AdjustElectricdowntiltaccordingtoengineeringdesign.Defaultis0 (allextended)
2006,ZTECorporation.Allrightsreserved.
PilotPollution:AnIssuetoConsiderWhenInstallingUMTS Antennas
n n
n n
OnUMTSandotherCDMAnetworksaCommonPilotSignalChannel (CPICH)isusedtoestimatethequalityofthechannel,cellselectionand handover.ThisisnotnecessaryonGSMnetworks. ThepoweroftheCPICHsignaldefinesthecellcoverageandhasadirect impactonthecellcapacityandthequalityoftheservice. UsualCPICHsignalpowerisbetween30and33dBmanditsdinamically adjustedbythenodeBaccordingtothequantityofsubscribersattachedto thecell.Itwilldecreasepowerasmoresubscribersgetconnectedtothecell. Subscribersarevirtuallyattachedtoachannel.SeveralnodeBcanoverlapa pointwiththesamechanneltomakepossiblethesofthandoffofthe subscriberswhenmovingfromonecelltoanother.Subscribersremainon thesamechannelwhenmovesfromonecelltoanother. Whenlocatedontheoverlappedarea,asubscribermaybeconnectedto severalcellssimultaneously. ReceivingEqualpowerCPICHsignalsormultiplestrongCPICHsignalswith itsmultipathcomponentsformcellsthatdoesntbelongtothecurrentActive SetcausesPilotPollution OnPilotpollutedenvironments,signalingpowerconsumptionincreases, reducingthepoweravailableforsubcriberstrafficthecallestablishing processisaffectedandalsothedegradationofthequalityofthesignalis noticeable,thepilotpollutiondegradestheFrameErrorRate(FER)andBit Errorrate(BER)increasingthenumberofterminatedcalls. ExposingthejumperoftheUMTSantennatotherearlobeofaynantenna mayincreasethepilotsignalpower,generatingpilotpollution.
2006,ZTECorporation.Allrightsreserved.
InstallationofRET(RemoteElectricTilt)control
n
InstallAndrewATM200A20actuatoronAntennaElectricTilt Adjustmentdevice:
l l l l
2006,ZTECorporation.Allrightsreserved.
nConnect3mAISGcablebetweenFirstATM200A20actuatorand
ALPD,and3mAISGcablefromALPDtoRRU
2006,ZTECorporation.Allrightsreserved.
nConnect5mAISGcablebetweenATM200A20actuatorsinachain
topology
RCU
RCU
RCU
RRU BBU
ALP D
RRU
RRU
O pt i cal f i ber
2006,ZTECorporation.Allrightsreserved.
WaterproofTreatmentforCables&Connectors