Sei sulla pagina 1di 1

MOUDA SUPER THERMAL POWER PROJECT

DRAWING NO.
WBS CODE :
SCALE : NONE
DRAWN BY :
CHECKED BY :
APPROVED BY :
DATE :
DATE :
DATE :
STAGE II - 2X660MW
00212 - 1E8501
00212
13-JUL-12 MS
03 & 04
PTS 13-JUL-12
LES 13-JUL-12
E
PROCESS AND INSTRUMENTATION DIAGRAM
55883100
SYMBOLS & LEGENDS
01
APPR.
BY
CHECK
BY
DRAWN
BY
DATE
LES LES 15-Oct-12 01 C4 - FOR APPROVAL
REV MODIFICATIONS
LES MS 13-JUL-12 00 C0 - FOR REVIEW AND APPROVAL
PTS
PTS
CONTRACT NO. UNIT NO.
THIS DRAWING IS THE PROPERTY OF
ALSTOM Power Inc.
WINDSOR, CONNECTICUT 06095
THIS DOCUMENT CONTAINS
PROPRIETARY DATA AND MAY NOT
BE REPRODUCED OR DISCLOSED
WITHOUT WRITTEN PERMISSION OF
ALSTOM Power Inc.
REV.
NTPC DRGNO
CUSTOMER
PROJECT
355-029
PROJECTION
ALL DIMENSIONS IN MILLIMETRE
SCALE
DRG. NO.
BHEL CUSTOMERNo :
C
A
U
T
IO
N
: T
H
E
IN
F
O
R
M
A
T
IO
N
O
N
T
H
IS
D
O
C
U
M
E
N
T
IS
T
H
E
P
R
O
P
E
R
T
Y
O
F
B
H
A
R
A
T
H
E
A
V
Y
E
LE
C
T
R
IC
A
LS
LIM
IT
E
D
. IT
M
U
S
T
N
O
T
B
E
U
S
E
D
D
IR
E
C
T
LY
O
R
IN
D
IR
E
C
T
LY
IN
A
N
Y
W
A
Y
D
E
T
R
IM
E
N
T
A
L T
O
T
H
E
IN
T
E
R
E
S
T
O
F
T
H
E
C
O
M
P
A
N
Y
.
LtL. tL` LLL.L!L L!`!.LL.

NTPC LIMITED
MOUDA SUPER THERMAL POWER PROJECT
STAGE-II (2X660MW)
REV
1711 & 1712
9575-102-01-TR-PVM-W-0758
0-00-047-48447
STEAM GENERATOR PACKAGE
2009 ALSTOM
01
3
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
2 1 4 5 56 7 8
3 2 1 4 5 6 7 8
GLOBE VALVE, OPEN
GLOBE VALVE, CLOSED
BALL / PLUG VALVE, CLOSED
BALL / PLUG VALVE, OPEN
GATE VALVE, OPEN
GATE VALVE, CLOSED
KNIFE GATE VALVE
FOUR WAY VALVE
NEEDLE VALVE, OPEN
NEEDLE VALVE, CLOSED
REGULATING VALVE
THREE WAY VALVE
SAFETY VALVE, CLOSED
LOUVERED DAMPER
SLIDE GATE DAMPER
MOTOR
SOLENOID
PNEUMATIC PISTON, DOUBLE ACTING
HYDRAULIC PISTON, ON/OFF
DIAPHRAM, SINGLE ACTION
DIAPHRAM, MODULATING
DIAPHRAM, DOUBLE ACTING
CHAIN WHEEL
PNEUMATIC PISTON FOR OIL GUN
PNEUMATIC PISTON FOR TILT DRIVE
SPRING
SCREWED PIPE CAP
FLEXIBLE HOSE
ORIFICE
STEAM TRAP
FLOW NOZZLE
FLOW ELEMENT
FUNNEL
DRAIN
REDUCER
STRAINER
DUPLEX FILTER
ACCUMULATOR
AXIAL FAN
BLADE PITCH CONTROLLER
CENTRIFUGAL PUMP
DESUPERHEATER
SILENCER
COAL SILO
BELT CONVEYOR WITH CLEAN OUT
ELECTRIC HEATER
HEA IGNITOR
OIL GUN
FLAME SCANNER
VENT PLUG
SHELL/TUBE HEAT EXCHANGER
HEAT EXCHANGER
COAL PULVERIZER
BUTTERFLY VALVE, CLOSED
BUTTERFLY DAMPER
WALL BLOWER
LONG RETRACT SOOTBLOWER
PROCESS INSTRUMENT
INTEGRAL INSTRUMENT
TURBINE FLOW ELEMENT
BUTTERFLY VALVE, OPEN
PLUG VALVE, OPEN
PLUG VALVE, CLOSED
MIXING SPHERE
STEAM TRACED HFO PIPE
PITOT TUBE OR PITOT VENTURI TUBE
RESERVOIR WITH WEIRS
DRAIN TO CANAL
STEAM TRAP ASSEMBLY
CONICAL STRAINER
ATMOSPHERIC VENT
INSTRUMENT INSERT NUMBER
NON RETURN VALVE
BOILER WATER RECIRCULATION PUMP
BIPLANAR DAMPER
INCHING VALVE
PNEUMATIC PISTON, MODULATING
HEATING JACKET
ELECTRO-HYDRAULIC ACTUATOR
COOLER BYPASS VALVE
ATM = ATMOSPHERE
WELDED PIPE CAP
EVER0ENCY AlR V0T0R
COAL NOZZLE
M
S
C
HEA IGNITOR
FLAME SCANNER
002
T
128
CwR
Cw3
N
3w
lA
CC
E/H
A
INSTRUMENT & EQUIPMENT CODE LETTERS
AE - ANALYSIS ELEMENT
AP - ANALYSIS TEST TAP
AT - ANALYSIS TRANSMITTER
BE - FLAME SCANNER
EE - VOLTAGE TRANSFORMER
FE - FLOW ELEMENT
FI - FLOW INDICATOR
FT - FLOW TRANSMITTER
FP - FLOW TEST TAP
FS - FLOW SWITCH
HS - MANUAL SWITCH
IE - CURRENT TRANSFORMER
JT - POWER TRANSMITTER
LE - LEVEL ELEMENT
LG - LEVEL GAGE
LGL - LOCAL LEVEL GAGE
FSA - FLOW SWITCH ADEQUATE
FSL - FLOW SWITCH LOW
LGR - REMOTE LEVEL GAGE
LS - LEVEL SWITCH
LSL - LEVEL SWITCH LOW
LSLL - LEVEL SWITCH LOW LOW
LT - LEVEL TRANSMITTER
PC - PRESSURE CONTROLLER
PCY- POSITIONER, PRESSURE
PDI - DIFFERENTIAL PRESSURE GAGE
PDC - DIFFERENTIAL PRESSURE CONTROLLER
PDIC - DIFFERENTIAL PRESSURE INDICATINGCONTROLLER
PDSA - DIFFERENTIAL PRESSURE SWITCH ADEQUATE
PDS - DIFFERENTIAL PRESS SWITCH
PDSH - DIFFERENTIAL PRESSURE SWITCH HIGH
PDSL - DIFFERENTIAL PRESSURE SWITCH LOW
PDSS - DIFFERENTIAL PRESSURE SWITCH SATISFACTORY
PDT - DIFFERENTIAL PRESSURE TRANSMITTER
PI - PRESSURE GAGE
PP - PRESSURE TEST TAP
PSA - PRESSURE SWITCH ADEQUATE
PSHA - PRESSURE SWITCH HIGH ALARM
PSH - PRESSURE SWITCH HIGH
PSL - PRESSURE SWITCH LOW
PSLL - PRESSURE SWITCH LOW LOW
PT - PRESSURE TRANSMITTER
PY - I/P CONVERTER
SE - SPEED SENSOR
ST - SPEED TRANSMITTER
TE - TEMPERATURE ELEMENT
TI - TEMPERATURE GAGE
TIC - TEMPERATURE INDICATINGCONTROLLER
TP - TEMPERATURE TEST POINT
TSH - TEMPERATURE SWITCH HIGH
TSHH - TEMPERATURE SWITCH HIGH HIGH
TT - TEMPERATURE TRANSMITTER
VE - VIBRATION SENSOR
VT - VIBRATION TRANSMITTER
VZE - PROXIMITYELEMENT
WS - TORQUE SWITCH
ZSA - LIMIT SWITCH, ADVANCED
ZSC - LIMIT SWITCH, CLOSED
ZSE - LIMIT SWITCH, ENGAGED
ZSO - LIMIT SWITCH, OPEN
ZSR - LIMIT SWITCH, RETRACTED
ZT - POSITION TRANSMITTER
ZYA - SOLENOID, ADVANCE
ZYR - SOLENOID, RETRACT
VALVES & DAMPERS
VALVE OPERATORS
FITTINGS EQUIPMENT
VALVES FAILURE POSITIONS
FO- FAIL OPEN
FC - FAIL CLOSED
FL - FAIL IN PLACE
INSTRUMENT BUBBLES
-1E8501 SYMBOLS & LEGENDS
-1E8503 START-UP & WARM-UP SYSTEM
-1E8504 BOILER WATER CIRCULATION PUMP SYSTEM
-1E8505 ECONOMIZER SYSTEM
-1E8506 EVAPORATOR SYSTEM
REFERENCE P&I DRAWINGS
-1E8507 WATER SEPARATOR SYSTEM
-1E8508 SUPERHEATER SYSTEM (1/3)
-1E8509 SUPERHEATER SYSTEM (2/3)
-1E8511 SUPERHEATER SYSTEM (3/3)
-1E8512 REHEATER SYSTEM (1/2)
-1E8513 REHEATER SYSTEM (2/2)
-1E8516 WINDBOX DETAIL
-1E8517 LIGHT OIL SUPPLY & BURNER DETAIL
-1E8518 HEAVY OIL SUPPLY & BURNER DETAIL
-1E8520 COMBUSTION AIR & FLUE GAS SYSTEM (1/4)
-1E8521 COMBUSTION AIR & FLUE GAS SYSTEM (2/4)
-1E8522 COMBUSTION AIR & FLUE GAS SYSTEM (3/4)
-1E8523 COMBUSTION AIR & FLUE GAS SYSTEM (4/4)
-1E8524 COAL FEEDER & PULVERIZER SYSTEM (1/2)
-1E8525 COAL FEEDER & PULVERIZER SYSTEM (2/2)
-1E8527 SOOTBLOWER SYSTEM (1/2)
-1E8528 SOOTBLOWER SYSTEM (2/2)

FIT - FLOW TRANSMITTER W/ INDICATOR


FIS - FLOW SWITCH W/ INDICATOR
ZYC - SOLENOID, CLOSE
ZYO - SOLENOID, OPEN
FY - POSTIONER
SCOPE BREAK
BYSTEAM
GENERATOR
BYNON BOILER
CONSORTIUM
NOTES:
1. BLR ISLAND P&IDS ARE TYPICAL FOR UNITS 3 AND 4. FOR UNIT 4 TAGS
REPLACE TAG PREFIX "30" WITH "40".
2. WHEREVER TE IS SHOWN, IT IS TO BE PROVIDED WITH TEMPERATURE TRANSMITTER
(TT, NOT SHOWN FOR CLARITY) .
3. ALL TRANSMITTERS TO BE SUPPLIED WITH 2-VALVE MANIFOLD FOR ABSOLUTE
PRESSURE TRANSMITTERS ( 3-VALVE MANIFOLD FOR GAUG/VACUUM PRESSURE
TRANSMITTERS) AND 5-VALVE MANIFOLD FOR DP/LEVEL/FLOW TRANSMITTERS.
4. ALL PRESSURE MEASUREMENTS INDICATE GAGE UNLESS SPECIFICALLY NOTED
AS ABSOLUTE.
5. TAPPING INSERT DETAILS (SIZES) FOR DUCTS SHOWN ON DWG. 1D8570.
-1E8502 FLASH TANK DRAIN TANK & DISCHARGE SYSTEM
INSTRUMENT AIR
COOLING WATER SUPPLY
COOLING WATER RETURN
NITROGEN PURGE
SERVICE WATER
SERVICE FLUID ID FLAGS
CHEMICAL CLEANING
CL - CONDENSATE LOOP
DS - DIAPHRAGMSEAL
ZY - SOLENOID
F
F
FUTURE WALL BLOWERS
FUTURE LONGRETRACT SOOTBLOWERS
S ELECTROMATIC RELIEF VALVE
-1E8425 EMERGENCY COMPRESSED AIR TO AIR PRE-HEATERS
-1E8418 SEPARATOR SAFETY VALVE DRAIN PIPING
9575-102-01-TR-PVM-W-0758
9575-102-01-TR-PVM-L-0759
9575-102-01-TR-PVM-F-0760
9575-102-01-TR-PVM-F-0743
9575-102-01-TR-PVM-F-0744
NTPC DRAWING NUMBER
9575-102-01-TR-PVM-F-0745
9575-102-01-TR-PVM-F-0746 SH 1
9575-102-01-TR-PVM-F-0746 SH 2
9575-102-01-TR-PVM-F-0746 SH 3
9575-102-01-TR-PVM-F-0747 SH 1
9575-102-01-TR-PVM-F-0747 SH 2
9575-102-01-TR-PVM-F-0736 SH 1
9575-102-01-TR-PVM-F-0737 SH 3 OF 4
9575-102-01-TR-PVM-F-0737 SH 4 OF 4
9575-102-01-TR-PVM-F-0736 SH 2
9575-102-01-TR-PVM-F-0736 SH 3
9575-102-01-TR-PVM-F-0736 SH 4
9575-102-01-TR-PVM-F-0736 SH 5
9575-102-01-TR-PVM-F-0741 SH 1
9575-102-01-TR-PVM-F-0741 SH 2
9575-102-01-TR-PVM-F-0749 SH 1
9575-102-01-TR-PVM-F-0749 SH 2
-
-
-
ADJUSTABLE COAL FLOW ORIFICE