Sei sulla pagina 1di 1

Design of Steel Structures

Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

3.2.5.3 Combined shear and tension failure


Bolt Subjected to Combined Shear and Tension  A bolt required to resist both design shear force (Vsd) and design tensile force (Tnd) at the same time shall satisfy
2 2

V Te  d 1.0 Vsd Tnd

(3.13)

Where, V = applied shear; Vsd = design shear capacity; Te = externally applied tension and Tnd = design tension capacity. This gives a circular interaction curve as

shown in Fig. 3.11.

Bolts in a connection for which slip in the serviceability limit state shall be limited, which are subjected to a tension force, T, and shear force, V, shall satisfy (Cl.10.4.6)
2 2

V Te  d 1.0 Vsdf Tndf

(3.14) Vsdf = design shear strength; Te =

Where, V = applied shear at service load;

externally applied tension at service load; Tndf = design tension strength.

V/Vsdf 1.0

1.0

Te/Tndf

Fig. 3.11 Shear and Tension Interaction Curve

Indian Institute of Technology Madras

Potrebbero piacerti anche