Sei sulla pagina 1di 16

Alarm List

The following table lists all the possible alarms generated by the OptiX RTN 620 in alphabetical order. Table 1 Alarm list Alarm Name Description Alarm Severity Major Source

A_LOC

Loss of clock on the adding bus MSP protocol stopped manually Loss of GFP client signals

PO1, PH1, PD1, PL3 SCC

APS_MANUAL_STOP

Minor

ALM_GFP_dCSF

Critical

EFT4, EMS6, EFP6 EFT4, EMS6, EFP6 IFH2 SCC

ALM_GFP_dLFD

GFP frames are out of frame.

Major

AM_DOWNSHIFT APS_FAIL

Downshift of AM modes The APS protection switching fails. Indication of the APS protection switching AU alarm indication

Major Major

APS_INDI

Major

SCC

AU_AIS

Major

SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4 SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4 SD1, SL1, SDE, SLE, IF1A, IF1B, IF0A, IF0B, IFX, SL4 SD1, SL1, SDE, SLE, IF1A, IF1B, IF0A, IF0B,

AU_LOP

Loss of AU pointers

Major

B1_EXC

Excessive regenerator section (B1) errors

Minor

B1_SD

Signal degradation due to Minor excessive regenerator section (B1) errors

Table 1 Alarm list Alarm Name Description Alarm Severity Source

IFX, SL4 B2_EXC Excessive multiplex section (B2) errors Major SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4 SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4 SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4, PL3 EFT4, EMS6

B2_SD

Signal degradation due to excessive multiplex section (B2) errors

Minor

B3_EXC

Excessive higher order path (B3) bit errors

Major

B3_EXC_VC3

Excessive VC-3 path (B3) bit errors Signal degradation due to excessive higher order path (B3) errors

Major

B3_SD

Minor

SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4, PL3 EFT4, EMS6

B3_SD_VC3

Signal degradation due to excessive VC-3 path (B3) bit errors The logical board is not added on the NMS. Board not in position

Minor

BD_NOT_INSTALLED

Minor

SCC

BD_STATUS

Major

SD1, SL1, SDE, SLE, IF1A, IF1B, PO1, PH1, EFT4, EMS6, PXC, ODU, FAN, EOW, IF0A, IF0B, IFX, PD1, SL4, IFH2, EFP6 PO1, PH1, EFT4, EMS6,

BIP_EXC

Excessive BIP errors

Minor

Table 1 Alarm list Alarm Name Description Alarm Severity Source

IF0A, IF0B, IFX, PD1, IFH2, EFP6 BIP_SD Signal degradation due to excessive BIP errors Minor PO1, PH1, EFT4, EMS6, IF0A, IF0B, PD1, IFH2, EFP6 SCC PL3 ODU

BOOTROM_BAD C2_VCAIS CONFIG_NOSUPPORT

BOOTROM data check fails. C2 byte mismatch Configuration is not supported. Errors in the processing of system databases System databases in protection mode Alarm indication of 2 Mbit/s downstream signals Loss of 2M clock in upstream signals Loss of 2 Mbit/s line signals

Major Minor Major

DBMS_ERROR

Major

SCC

DBMS_PROTECT_MODE

Critical

SCC

DOWN_E1_AIS

Minor

PO1, PH1, PD1 PO1, PH1, PD1 PO1, PH1, PD1 SCC EMS6, EFP6 EMS6, EFP6 EMS6, EFP6

E1_LOC

Major

E1_LOS

Minor

ESN_INVALID ETH_CFM_LOC ETH_CFM_MISMERGE ETH_CFM_RDI

Invalid ESN Loss of connectivity Misconnection Failure in receiving CCM packets at the remote end Errored frames

Major Critical Critical Minor

ETH_CFM_UNEXPERI

Critical

EMS6, EFP6

Table 1 Alarm list Alarm Name Description Alarm Severity Critical Source

ETH_LOS

Loss of Ethernet port connection Discovery failure detected by point-to-point Ethernet OAM Severe fault detected by point-to-point Ethernet OAM at the remote end

EFT4, EMS6, IFH2, EFP6 EFT4, EMS6, EFP6 EMS6, EFP6

ETHOAM_DISCOVER_FAIL

Minor

ETHOAM_RMT_CRIT_FAULT

Minor

ETHOAM_RMT_LOOP

Remote loopback detected by Minor point-to-point Ethernet OAM Remote Ethernet performance degradation detected by point-to-point Ethernet OAM MAC port loopback detected by point-to-point Ethernet OAM Minor

EMS6, EFP6

ETHOAM_RMT_SD

EMS6, EFP6

ETHOAM_SELF_LOOP

Major

EMS6, EFP6

ETHOAM_VCG_SELF_LOOP

VCTRUNK loopback detected Minor by point-to-point Ethernet OAM Loss of periodical connectivity Critical check packets Conflict of MPIDs Loss of external clock sources Failure of synchronous data interfaces Failure of fan boards FCS errors Major Critical

EMS6, EFP6

EX_ETHOAM_CC_LOS

EMS6, EFP6

EX_ETHOAM_MPID_CNFLCT EXT_SYNC_LOS

EMS6, EFP6 SCC

F1PORT_FAILED

Minor

SCC

FAN_FAIL FCS_ERR

Major Critical

FAN EFT4, EMS6, EFP6 EMS6

FLOW_OVER

Excessive data traffic

Minor

Table 1 Alarm list Alarm Name Description Alarm Severity Source

received by Ethernet ports HARD_BAD Hardware errors Critical SD1, SL1, SDE, SLE, IF1A, IF1B, PO1, PH1, EFT4, PXC, SCC, ODU, EMS6, IF0A, IF0B, IFX, PD1, SL4, IFH2, EFP6 SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4 SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4 SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4

HP_CROSSTR

Threshold-crossing performance event of the higher order path

Minor

HP_LOM

Loss of multi-frames in the higher order path

Major

HP_RDI

Higher order path remote defect indication

Minor

HP_REI

Higher order path remote error indication

Warning SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4 Minor SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4 SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4 SD1, SL1, SDE, SLE, IF1A, IF1B,

HP_SLM

Higher order path signal label mismatch

HP_TIM

High order path trace identifier mismatch

Minor

HP_UNEQ

Unequipped higher order path Minor

Table 1 Alarm list Alarm Name Description Alarm Severity Source

IFX, SL4 HPAD_CROSSTR Adaptation performance threshold-crossing of the higher order path IF cables are disconnected. Minor PO1, PH1, PD1

IF_CABLE_OPEN

Major

IF1A, IF1B, IF0A, IF0B, IFX, IFH2 ODU

IF_INPWR_ABN

Abnormal power supplied by an IF board to an ODU Preset IF working mode not supported Over high input optical power Over low input optical power Trace identifier mismatch

Major

IF_MODE_UNSUPPORTED

Major

IF1A, IF1B

IN_PWR_HIGH IN_PWR_LOW J0_MM

Critical Critical Minor

SD1, SL1, SL4 SD1, SL1, SL4 SD1, SL1, SDE, SLE, IF1A, IF1B, SL4 SCC SCC EMS6, EFP6 EMS6, EFP6 SD1, SL1, SL4 SD1, SL1, SL4

K1_K2_M K2_M LAG_PORT_FAIL LAG_VC_PORT_FAIL LASER_CLOSED LASER_MOD_ERR_EX

K1 and K2 mismatch K2 mismatch A port of an LAG fails A VCG port of an LAG fails A laser is closed. The type of the pluggable optical module on the board does not match the type of the optical interface. LCAS protocol fails in the receive direction.

Minor Minor Minor Minor Major Major

LCAS_FOPR

Major

EFT4, EMS6, EFP6

Table 1 Alarm list Alarm Name Description Alarm Severity Major Source

LCAS_FOPT

LCAS protocol fails in the transmit direction Loss of partial bandwidth in the LCAS receive direction Loss of partial bandwidth in the LCAS transmit direction Loss of total bandwidth in the LCAS receive direction Loss of total bandwidth in the LCAS transmit direction The capacity of the configured services exceeds the range permitted by the license file The license file is not detected License file check fails Data link errors

EFT4, EMS6, EFP6 EFT4, EMS6, EFP6 EFT4, EMS6, EFP6 EFT4, EMS6, EFP6 EFT4, EMS6, EFP6 SCC, IFH2

LCAS_PLCR

Minor

LCAS_PLCT

Minor

LCAS_TLCR

Major

LCAS_TLCT

Major

LCS_LIMITED

Major

LICENSE_LOST

Major

SCC, IFH2

LICENSE_ERR LINK_ERR LPS_UNI_BI_M

Major Critical

SCC, IFH2 EMS6 SCC

The switching mode is single- Minor ended at one end and dualended at the other end. A loopback occurs. Minor

LOOP_ALM

SD1, SL1, SDE, SLE, IF1A, IF1B, PO1, PH1, EFT4, EMS6, ODU, IF0A, IF0B, IFX, PD1, SL4, IFH2, EFP6 EFT4, EMS6

LPT_INEFFECT

Link state pass-through function fails.

Major

Table 1 Alarm list Alarm Name Description Alarm Severity Critical Source

LPT_RFI

Link state pass-through function fails at the remote end. Performance thresholdcrossing of the lower order path FIFO overflow at the receive side of the lower order path Lower order path remote defect indication

EFP6, EFT4, EMS6

LP_CROSSTR

Minor

PO1, PH1, PD1

LP_R_FIFO

Minor

PO1, PH1, PD1, PL3 PO1, PH1, IF0A, IF0B, PD1, PL3, IFH2 EFT4, EMS6, EFP6 EFT4, EMS6

LP_RDI

Minor

LP_RDI_VC12

Remote defect indication in the VC-12 lower order path Remote defect indication in the VC-3 lower order path

Minor

LP_RDI_VC3

Minor

LP_REI

Lower order path remote error Minor indication

PO1, PH1, IF0A, IF0B, PD1, PL3, IFH2 EFT4, EMS6, EFP6 EFT4, EMS6

LP_REI_VC12

Remote error indication in the Minor VC-12 lower order path Remote error indication in the Minor VC-3 lower order path Lower order path remote failure indication Errors of TU specifications Minor

LP_REI_VC3

LP_RFI

PO1, PH1, PD1, IFH2 PO1, PH1, PD1 PO1, PH1, PD1, PL3 EFT4, EMS6,

LP_SIZE_ERR

Minor

LP_SLM

Lower order path signal label mismatch Signal label mismatch in the

Minor

LP_SLM_VC12

Minor

Table 1 Alarm list Alarm Name Description Alarm Severity Source

VC-12 lower order path LP_SLM_VC3 Signal label mismatch in the VC-3 lower order path FIFO overflow at the transmit side of the lower order path Lower order path trace identifier mismatch Lower order path trace identifier mismatch at VC-12 level Lower order path trace identifier mismatch at VC-3 level Unequipped lower order paths Minor

EFP6 EFT4, EMS6

LP_T_FIFO

Minor

PO1, PH1, PD1, PL3 PO1, PH1, PD1, PL3 EFT4, EMS6, EFP6

LP_TIM

Minor

LP_TIM_VC12

Minor

LP_TIM_VC3

Minor

EFT4, EMS6

LP_UNEQ

Minor

PO1, PH1, IF0A, IF0B, PD1, PL3, IFH2 EFT4, EMS6, EFP6 EFT4, EMS6

LP_UNEQ_VC12

Unequipped VC-12 lower order paths

Minor

LP_UNEQ_VC3

Unequipped VC-3 lower order Minor paths Laser not installed Critical

LSR_NO_FITED LSR_WILL_DIE

SD1, SL1, SL4 SL4

The life of the laser is close to Critical the end. Loss of all clock sources Port module type mismatch Multiplex section alarm indication Major Critical Major

LTI MOD_TYPE_MISMATCH MS_AIS

SCC EMS6 SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4

Table 1 Alarm list Alarm Name Description Alarm Severity Source

MS_CROSSTR

Multiplex section performance Minor threshold-crossing

SD1, SL1, SDE, SLE, IF1A, IF1B, SL4 SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4

MS_RDI

Multiplex section remote defect indication

Minor

MS_REI

Multiplex section remote error Warning SD1, SL1, indication SDE, SLE, IF1A, IF1B, IFX, SL4 Multiplex section adaptation performance thresholdcrossing Minor SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4 SCC

MSAD_CROSSTR

MSSW_DIFFERENT

The active board and the standby board have inconsistent software. The ring network has multiple RPL_OWNER nodes. Excessive errors on radio links Signal degradation due to excessive errors on radio links

Major

MULTI_RPL_OWNER

Minor

EMS6

MW_BER_EXC

Minor

IFH2

MW_BER_SD

Minor

IFH2

MW_FEC_UNCOR

FEC errors are uncorrectable. Minor

IF1A, IF1B, IF0A, IF0B, IFX, IFH2 IF1A, IF1B, IF0A, IF0B, IFX, IFH2 IF1A, IF1B, IF0A, IF0B, IFX, IFH2

MW_LIM

Label mismatch on radio links Major

MW_LOF

Loss of microwave frames

Critical

Table 1 Alarm list Alarm Name Description Alarm Severity Minor Source

MW_RDI

Remote defect indication on radio links

IF1A, IF1B, IF0A, IF0B, IFX, IFH2 SCC SCC

NESF_LOST NESTATE_INSTALL

Loss of NE software The NE is in the installation state. No board software exists

Critical Critical

NO_BD_SOFT

Critical

SD1, SL1, SDE, SLE, IF1A, IF1B, PXC, IF0A, IF0B, IFX, SL4, EMS6, IFH2, EFP6 SCC

NP1_MANUAL_STOP

The N+1 protection protocol is stopped manually. The N+1 protection switching fails N+1 protection switching indication Output of optical power fails. The connections of the protection pair are abnormal. Port not in position Power module alarm

Minor

NP1_SW_FAIL

Major

SCC

NP1_SW_INDI

Major

SCC

OPM_FAIL PROT_CONN_ERR

Major Major

SL4 EMS6, EFP6

PORT_MODULE_OFFLINE POWER_ALM

Major Major

EMS6 PXC, SCC, FAN PL3

P_AIS

PDH interface signal alarm indication Loss of signals at PDH interfaces Indication of the triggered

Major

P_LOS

Major

PL3

PS

Major

PO1, PH1,

Table 1 Alarm list Alarm Name Description Alarm Severity Source

protection switching RADIO_FADING_MARGIN_INSUFF Radio fading margin is insufficient. RADIO_RSL_BEYONDTH R_F_RST Antennas are not aligned. Reset of the receive FIFO Minor

PD1 ODU

Minor Minor

ODU PO1, PH1, PD1 SD1, SL1, SDE, SLE, IF1A, IF1B, IF0A, IF0B, IFX, SL4, IFH2 SD1, SL1, SDE, SLE, IF1A, IF1B, IF0A, IF0B, IFX, SL4, IFH2 SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, IF0A, IF0B, SL4 PO1, PH1, PD1

R_LOC

Loss of clock on the receive line side

Critical

R_LOF

Loss of frame on the receive line side

Critical

R_LOS

Loss of signal on the receive line side

Critical

R_S_ERR

Errors in the received signal

Critical

RADIO_MUTE

The radio transmitter is muted.

Warning ODU

RADIO_RSL_HIGH

Over high radio receive signal Critical level Over low radio receive signal level Over high radio transmit signal level Critical

ODU

RADIO_RSL_LOW

ODU

RADIO_TSL_HIGH

Critical

ODU

Table 1 Alarm list Alarm Name Description Alarm Severity Source

RADIO_TSL_LOW

Over low radio transmit signal Critical level Relay alarm Loss of the received phaselocked clock Indication of the radio protection switching Regenerator section performance thresholdcrossing Critical Major

ODU

RELAY_ALARM RP_LOC

EOW PO1, PH1, PD1 SCC

RPS_INDI

Major

RS_CROSSTR

Minor

SD1, SL1, SDE, SLE, IF1A, IF1B, IFX, SL4 SCC

RTC_FAIL

The real time clock (RTC) of the equipment fails. Clock source switching in S1 byte mode The activation timeout of the software package

Major

S1_SYN_CHANGE

Major

SCC

SWDL_ACTIVATED_TIMEOUT

Critical

SCC

SWDL_AUTOMATCH_INH

The automatic match function Minor is disabled The board software version and the running software version are inconsistent NE submission failure The NE is in the process of package loading. Loss of files in a software package Files are deleted when they are customized. Critical

SCC

SWDL_CHGMNG_NOMATCH

SCC

SWDL_COMMIT_FAIL SWDL_INPROCESS

Minor Minor

SCC SCC

SWDL_NEPKGCHECK

Critical

SCC

SWDL_PKG_NOBDSOFT

Minor

SCC

Table 1 Alarm list Alarm Name Description Alarm Severity Critical Source

SWDL_PKGVER_MM

Software package version consistency check fails. The version rollback on an NE fails. Synchronous source degradation The priority of the synchronous clock source is lost. Loss of analog signals at 2 Mbit/s interfaces Reset of the transmit FIFO

SCC

SWDL_ROLLBACK_FAIL

Minor

SCC

SYN_BAD

Minor

PXC

SYNC_C_LOS

Warning SCC

T_ALOS

Major

PO1, PH1, PD1 PO1, PH1, PD1 SD1, SL1, SDE, SLE, SL4 SD1, SL1, SDE, SLE, SL4 IF1A, IF1B, EFT4, PXC, SCC, EMS6, IF0A, IF0B, IFX, IFH2, EFP6, ODU PO1, PH1, IF0A, IF0B, PD1, PL3, IFH2 EFT4, EMS6, EFP6 EFT4, EMS6

T_F_RST

Minor

T_LOC

Loss of clock on the transmit line side

Major

T_LOS

Loss of signal on the transmit line side

Major

TEMP_ALARM

The ambient temperature of the board crosses the threshold.

Minor

TU_AIS

TU alarm indication

Major

TU_AIS_VC12

TU alarm indication at VC-12 level TU alarm indication at VC-3 level

Major

TU_AIS_VC3

Major

Table 1 Alarm list Alarm Name Description Alarm Severity Major Source

TU_LOP

Loss of TU pointers

PO1, PH1, IF0A, IF0B, PD1, PL3, IFH2 EFT4, EMS6, EFP6 EFT4, EMS6

TU_LOP_VC12

Loss of TU pointers at VC-12 level Loss of TU pointers at VC-3 level Alarm indication of 2 Mbit/s upstream signals Loss of virtual concatenation alignment Loss of multiframe of VC-12 path virtual concatenation Loss of multiframe of VC-3 path virtual concatenation SQ mismatch of VC-12 path virtual concatenation SQ mismatch of VC-3 path virtual concatenation Loss of voltage

Major

TU_LOP_VC3

Major

UP_E1_AIS

Minor

PO1, PH1, PD1 EFT4, EMS6, EFP6 EFT4, EMS6, EFP6 EFT4, EMS6

VCAT_LOA

Critical

VCAT_LOM_VC12

Major

VCAT_LOM_VC3

Major

VCAT_SQM_VC12

Major

EFT4, EMS6, EFP6 EFT4, EMS6

VCAT_SQM_VC3

Major

VOLT_LOS

Major

PXC, IF1A, IF1B, IF0A, IF0B, IFX, IFH2 SCC SCC PXC

WRG_BD_TYPE WRG_DEV_TYPE WS_LOS

Errors of board types Errors of equipment types Loss of wayside signals at 2 Mbit/s electrical interfaces Read and write registers of the board chip fail.

Major Critical Major

W_R_FAILURE

Major

EMS6, EFP6

Table 1 Alarm list Alarm Name Description Alarm Severity Major Source

XCP_INDI

The active/standby switching of cross-connect and timing boards occurs. Loss of XPIC compensation signals

SCC

XPIC_LOS

Critical

IFX

NOTE: All alarmed boards refer to the logical boards displayed on the NMS. Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.