Sei sulla pagina 1di 2

Job ID : PRUEBAS RETRODIFUSAS Contractor : OFFSHORE&INDIGI MACRONET Customer : EP PETROECUADOR MACRONET Test Date : 19/12/2012 (11:16:16) Fiber ID : Fiber0012

Location A : 39600- PULINGUI NITILUISA Cable Mfr. : DRAKA G.652 D Subset ID : BUFFER AZUL Link Loss Link Length dB Average Loss 35.05 dB : 0.964 dB : 5.0801 km : 0.190 dB/km

ABS. 39600-44600_H12.TRC - OTDR Report 1550 nm Job Info


Reason Operator A File Cable ID Location B Type Color ID

: VERIFICAR ESTADO DE FO : Operator B : : ABS. 39600-44600_H12.TRC : DRAKA_100957334 : 44600: : CELESTE : 0.108 dB : 0.139 :

Cable Info

Link Measurements

Avg. Splice Loss Max. Splice Loss Total ORL

OTDR Trace
dB

30.00

25.00

20.00

15.00

2
10.00

AB
5.00

0.00 1 2 3 4 5 6 7 km

Events Table
No. 1 2 3 4 Loc. (km) 0.0000 2.9076 4.2854 5.0801 Event Type Launch Level Fiber Section (2.9076 km) Non-Reflective Fault Fiber Section (1.3778 km) Non-Reflective Fault Fiber Section (0.7947 km) Reflective Fault Loss (dB) --0.501 0.077 0.168 0.139 0.079 --Refl. (dB) -43.4 0.172 0.122 0.100 -63.9 Att. (dB/km) Cumul. (dB) 0.000 0.501 0.578 0.745 0.884 0.964 0.964

W avelength Filename Hardware Serial Number dB Software -72.0 dB Range IOR RBS

: : : :

1550 nm (SM) ABS. 39600-44600_H12.TRC AXS-100-023B-EI-04B-EI-PM2X-VFL 479143 : N/A

Test and Cable Setup

Acq. Time : Pulse W idth : Helix Factor : Splice Loss Threshold : Reflectance Threshold

15 s 30 ns 0.00 % 0.050 :

: 7.5 km : 1.46833 : -81.87

End-of-Fiber Threshold

: 5.000 dB

Potrebbero piacerti anche