Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Instruction manual
Contents
1 2 3 4 Description Specifications Installation requirements Installation Commissioning 5 6 7 8 Troubleshooting Components used Packing slip Warranty 9 Theory 10 Software 11 Experiments
APEX INNOVATIONS
17-06-2008 Im224 Page 1
Apex Innovations
Description
The setup consists of single cylinder, four stroke, Diesel engine connected to eddy current type dynamometer for loading. It is provided with necessary instruments for combustion pressure and crank-angle measurements. These signals are interfaced to computer through engine indicator for PPV diagrams. Provision is also made for interfacing airflow, fuel flow, temperatures and load measurement. The set up has stand-alone panel box consisting of air box, fuel tank, manometer, fuel measuring unit, transmitters for air and fuel flow measurements, process indicator and engine indicator. Rotameters are provided for cooling water and calorimeter water flow measurement. The setup enables study of engine performance for brake power, indicated power, frictional power, BMEP, IMEP, brake thermal efficiency, indicated thermal efficiency, Mechanical efficiency, volumetric efficiency, specific fuel consumption, A/F ratio and heat balance. Labview based Engine Performance Analysis software package EnginesoftLV is provided for on line performance evaluation. A computerized Diesel injection pressure measurement is optionally provided.
Specifications
Product Engine test setup 1 cylinder, 4 stroke, Diesel (Computerized) Product code 224 Engine Make Kirloskar, Model TV1, Type 1 cylinder, 4 stroke Diesel, water cooled, power 5.2 kW at 1500 rpm, stroke 110 mm, bore 87.5 mm. 661 cc, CR 17.5 Dynamometer Type eddy current, water cooled, with loading unit Propeller shaft With universal joints Air box M S fabricated with orifice meter and manometer Fuel tank Capacity 15 lit with glass fuel metering column Calorimeter Type Pipe in pipe Piezo sensor Range 5000 PSI, with low noise cable Crank angle sensor Resolution 1 Deg, Speed 5500 RPM with TDC pulse. Data acquisition device NI USB-6210, 16-bit, 250kS/s. Piezo powering unit Make-Cuadra, Model AX-409.
17-06-2008
Im224
Page 2
Apex Innovations Digital milivoltmeter Temperature sensor Temperature transmitter Load indicator Load sensor Fuel flow transmitter Air flow transmitter Software Rotameter Pump Overall dimensions Optional Range 0-200mV, panel mounted Type RTD, PT100 and Thermocouple, Type K Type two wire, Input RTD PT100, Range 0100 Deg C, Output 420 mA and Type two wire, Input Thermocouple, Range 01200 Deg C, Output 420 mA Digital, Range 0-50 Kg, Supply 230VAC Load cell, type strain gauge, range 0-50 Kg DP transmitter, Range 0-500 mm WC Presure transmitter, Range (-) 250 mm WC EnginesoftLV Engine performance analysis software Engine cooling 40-400 LPH; Calorimeter 25-250 LPH Type Monoblock W 2000 x D 2500 x H 1500 mm Computerized Diesel injection pressure measurement
Product 224 Shipping details Gross volume 1.33m3, Gross weight 619kg, Net weight 543kg
Installation requirements
Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. (Neutral Earth voltage less than 5 VAC) 5A, three pin socket with switch (2 Nos.) Water supply Continuous, clean and soft water supply @ 1000 LPH, at 10 m. head. Provide tap with 1 BSP size connection Computer IBM compatible with standard configuration (with free PCI slot on motherboard) Space 3300Lx3200Wx1700H in mm Drain Provide suitable drain arrangement (Drain pipe 65 NB/2.5 size) Exhaust Provide suitable exhaust arrangement (Exhaust pipe 32 NB/1.25 size) Foundation As per foundation drawing Fuel, oil Diesel@10 lit. Oil @ 3.5 lit. (20W40)
Installation Commissioning
INSTALLATION
Unpack the box(es) received and ensure that all material is received as per packing slip (provided in instruction manual). In case of short supply or breakage contact Apex Innovations / your supplier for further actions. Install engine test set up assembly on the foundation. Keep panel box structure near foundation (Refer foundation drawing ) Fit the panel box assembly on the panel box structure and fit following parts
17-06-2008
Im224
Page 3
Apex Innovations o Piezo powering unit o Loading unit o Load indicator o Digital voltmeter Complete the piping work as follows: o Exhaust: Engine to calorimeter o Water: Dynamometer inlet, outlet, Engine cooling inlet, outlet, Calorimeter water inlet outlet and drain pipe. o Air: Air box to engine o Fuel: Fuel measuring unit to engine Fit the following parts o Piezo sensor in the engine head. o Pressure gauge on dynamometer inlet pipe. o Temperature sensors o Crank angle sensor on dynamometer (non driving end) o Load cell to dynamometer. Complete the wiring work as follows: o Crank angle sensor to Piezo powering unit o Piezo sensor to Piezo powering unit o Load cell to load indicator o Temperature sensors to engine panel o DLU unit to Dynamometer o USB cable from Data acquisition device to computer USB port.
COMMISSIONING
Fill lubrication oil in the engine and fuel in the fuel tank. Remove air from fuel line connecting fuel measuring unit to fuel transmitter. Lower jack bolts under dynamometer for free movement. Provide electric supply to panel box o Adjust crank angle sensor for TDC matching. o Confirm all temperatures are correctly displayed on process indicator o Confirm load signal displayed on process indicator Fill water in the manometer up to 0 mark level. Keep Load knob on loading unit is at minimum position. Load the NI-USB driver on the computer from Driver CD. Connect signal cable from Data acquisition device to computer. Load EnginesoftLV software package on the same computer. Ensure water circulation through engine, calorimeter and dynamometer. Start the Engine. Check engine operation at various loads and ensure respective signals on computer.
Precautions
Use clean and filtered water; any suspended particle may clog the piping. Piezo Sensor Handling: o Ensure cooling water circulation for combustion pressure sensor. o Diaphragm of the sensor is delicate part. Avoid scratches or hammering on it. o A long sleeve is provided inside the hole drilled for piezo sensor. This sleeve is protecting the surface of the diaphragm. While removing the sensor, this sleeve may come out with the sensor and fall down or lose during handling.
17-06-2008
Im224
Page 4
Apex Innovations o Status of the sensor is indicated on the Piezo powering unit. Damages to the electronic parts of the sensor or loose connection are indicated as "open" or "short" status on Piezo powering unit. Circulate dynamometer and engine cooling water for some time after shutting down the engine.
17-06-2008
Im224
Page 5
Apex Innovations
Troubleshooting
Note: For component specific problems refer components manual Problems Possible causes / remedies Engine does not start Insufficient fuel Air trapped in fuel line Dynamometer does Faulty wiring not load the engine No DC voltage at the outlet of dynamometer loading unit Faulty air flow Air hose leakage at connections with air-box and with engine. Faulty fuel flow Improper closing of fuel cock. Air trap in pressure signal line to fuel transmitter Software does not Faulty or wrong USB port work Virus in computer Loose connections Faulty indicated TDC setting disturbed. Readjust TDC setting. power Improper configuration data Faulty pressure crank Improper earthing angle diagram Wrong reference pressure setting in configuration file. Adjust the value such that suction stroke pressure just matches the zero line. If peak pressure is not at the TDC, TDC setting disturbed, readjust If peak pressure shifts randomly with respect to TDC, coupling of crank angle sensor may be loose Faulty speed Broken coupling of crank angle sensor indication Incorrect Check the connection between thermocouple and temperature temperature indicator/transmitter. Note that yellow indication cable of thermocouple is positive and red is negative. Open or damaged temperature sensor Improper load Excessively raised jack bolts of the dynamometer. indication TDC Setting The TDC indicator provided on the engine indicator enables matching of index pulse of crank angle sensor with TDC(Top Dead Centre) of the cylinder. Take the piston to its TDC position (match mark provided on the engine fan/pulley/flywheel). Loosen the screws of clamping flange of engine crank angle sensor. Slowly rotate the crank angle sensor body till the TDC indicator lamp glows. At this position clamp the flange screws to fix the crank angle sensor at this position.
17-06-2008
Im224
Page 6
Apex Innovations
Components used
Components
Engine
Details
Make Kirloskar, Model TV1, Type Single cylinder, 4 stroke Diesel, water cooled, power 5.2 kW (7 BHP) at 1500 rpm, stroke 110 mm, bore 87.5 mm. compression ratio 17.5:1, capacity 661 cc. Make Saj test plant Pvt. Ltd., Model AG10, Type Eddy current Make Apex, Model AX-155. Type constant speed, Supply 230V AC. Make Hindustan Hardy Spicer, Model 1260, Type A Make Apex, Model MX-104, Range 100-0-100 mm, Type U tube, Conn. 1/4`` BSP hose back side, Mounting panel Make Apex, Glass, Model:FF0.012 Make PCB Piezotronics, Model HSM111A22, Range 5000 psi, Diaphragm stainless steel type & hermetic sealed Make PCB piezotronics, Model 002C20, Length 20 ft, Connections one end BNC plug and other end 10-32 micro Make Kubler-Germany Model 8.3700.1321.0360 Dia: 37mm Shaft Size: Size 6mmxLength 12.5mm, Supply Voltage 5-30V DC, Output Push Pull (AA,BB,OO), PPR: 360, Outlet cable type axial with flange 37 mm to 58 mm NI USB-6210 Bus Powered M Series, Make-Cuadra, Model AX-409. Make Radix Type K, Ungrounded, Sheath Dia.6mmX110mmL, SS316, Connection 1/4"BSP (M) adjustable compression fitting Make Radix, Type Pt100, Sheath Dia.6mmX110mmL, SS316, Connection 1/4"BSP(M) adjustable compression fitting Make Wika, model T19.10.3K0-4NK-Z, Input Thermocouple (type K), output 4-20mA, supply 24VDC, Calibration: 0-1200deg.C. Make Wika, Model T19.10.1PO-1 Input RTD(Pt100), output 4-20mA, supply 24VDC, Calibration: 0-100C Make Sensotronics Sanmar Ltd., Model 60001,Type S beam, Universal, Capacity 0-50 kg Make Selectron, model PIC 152B2, 85 to 270VAC, retransmission output 4-20 mA Make Meanwell, model S-15-24, O/P 24 V, 0.7 A Make Meco, 3.1/2 digit LED display, range 0-20 VDC, supply 230VAC, model SMP35 Make Yokogawa, Model EJA110-EMS-5A-92NN, Calibration range 0-500 mm H2O, Output linear Make Wika, Range (-) 250 mm WC
Dynamometer Dynamometer Loading unit Propeller shaft Manometer Fuel measuring unit Piezo sensor White cable coaxial teflon
Data acquisition device Piezo powering unit Temperature sensor Temperature sensor Temperature transmitter Temperature transmitter Load sensor Load indicator Power supply Digital voltmeter Fuel flow transmitter Air flow transmitter
17-06-2008
Im224
Page 7
Apex Innovations Rotameter Rotameter Pump Make Eureka Model PG 5, Range 25-250 lph, Connection 3/4" BSP vertical, screwed, Packing neoprene Make Eureka Model PG 6, Range 40-400 lph, Connection BSP vertical, screwed, Packing neoprene Make Kirloskar, Model Mini 18SM, HP 0.5, Size 1 x 1, Single ph 230 V AC
Packing slip
Box No.1/8 1 Box No.2/8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Size W975xD475xH500 mm; Volume:0.23m3 Engine panel box assembly Size W500xD400xH300 mm; Volume:0.06m3 Piezo powering unit Load indicator Digital voltmeter Dynamometer loading unit Pressure gauge Wiring set Load cell with nut bolt Crank angle sensor Temperature sensor Piezo sensor Low noise cable Data acquisition device and driver CD Set of loose nut bolts Tool kit Set of instruction manuals consisting of: Instruction manual CD (Apex) DP transmitter Dynamometer Piezo sensor Size W800xD475xH500 mm; Volume:0.19m3 Engine panel box structure Size W725xD250xH325 mm; Volume: 0.06m3 Calorimeter assembly Calorimeter support structure Size W900xD200xH200 mm; Volume: 0.04m3 Exhaust pipe Size W300xD225xH300 mm; Volume:0.02m3 Pump Size W1250xD450xH350mm; Volume: 0.15m3 Gross weight: 70kg Net weight: 52kg 1 No. Gross weight: 25kg Net weight: 18kg 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 5 Nos. 1No/2Nos. 1No/2Nos. 1 No. 1 No. 1 No. 1 No.
Box No.3/8 1 Box No.4/8 1 2 Box No.5/8 1 Box No.6/8 1 Box No.7/8
Gross weight: 46kg Net weight: 31kg 1 No. Gross weight: 24kg Net weight: 17kg 1 No. 1 No. Gross weight: 16kg Net weight: 10kg 1 No. Gross weight: 14kg Net weight: 7kg 1 No. Gross weight: 42kg Net weight: 28kg
17-06-2008
Im224
Page 8
Apex Innovations 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Case No.8/8 1 Piping set (13 pieces) Fuel measuring unit Funnel Fuel cap Wiring channel set (5 pieces) Starting kick/Handle Engine air inlet Engine silencer Pump support Water supply hose pipe 1.25 socket with pipe 1.25 socket with flange Ball valve Teflon tape(2Nos.), Gasket bottle (1No.) Open packing; Volume:0.61m3 Engine test setup assembly and water supply pipe 1 No. 2 Nos. 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. Gross weight: 380kg Net weight: 380kg 1 No.
17-06-2008
Im224
Page 9
Apex Innovations
Warranty
This product is warranted for a period of 12 months from the date of supply against manufacturing defects. You shall inform us in writing any defect in the system noticed during the warranty period. On receipt of your written notice, Apex at its option either repairs or replaces the product if proved to be defective as stated above. You shall not return any part of the system to us before receiving our confirmation to this effect. The foregoing warranty shall not apply to defects resulting from: Buyer/ User shall not have subjected the system to unauthorized alterations/ additions/ modifications. Unauthorized use of external software/ interfacing. Unauthorized maintenance by third party not authorized by Apex. Improper site utilities and/or maintenance. We do not take any responsibility for accidental injuries caused while working with the set up.
17-06-2008
Im224
Page 10
Apex Innovations
Theory TERMINOLOGY
Engine Cylinder diameter (bore) (D): The nominal inner diameter of the working cylinder. Piston area (A): The area of a circle of diameter equal to engine 2 cylinder diameter (bore). A = / 4 D Engine Stroke length (L): The nominal distance through which a working piston moves between two successive reversals of its direction of motion. Dead center: The position of the working piston and the moving parts, which are mechanically connected to it at the moment when the direction of the piston motion is reversed (at either end point of the stroke). Bottom dead center (BDC): Dead center when the piston is nearest to the crankshaft. Sometimes it is also called outer dead center (ODC). Top dead center (TDC): Dead center when the position is farthest from the crankshaft. Sometimes it is also called inner dead center (IDC). Swept volume (VS): The nominal volume generated by the working piston when travelling from one dead center to next one, calculated as the product of piston area and stroke. The capacity described by engine manufacturers in cc 2 is the swept volume of the engine. Vs = A L = / 4 D L Clearance volume (VC): The nominal volume of the space on the combustion side of the piston at top dead center. Cylinder volume: The sum of swept volume and clearance volume. V = Vs + Vc Compression ratio (CR): The numerical value of the cylinder volume divided by the numerical value of clearance volume. CR = V / Vc
17-06-2008
Im224
Page 11
Apex Innovations
Bore D
Cylinder head Suction valve Intake or suction manifold Exhaust valve Exhaust manifold
Top dead center T.D.C. Piston Gudgeon or wrist pin Bottom dead center B.D.C.
Clearance volume.Vc
17-06-2008
Im224
Page 12
Apex Innovations 1. Compression stroke: The piston travels up the cylinder, so compressing the trapped charge. If the fuel is not pre-mixed, the fuel is injected towards the end of the compression stroke; ignition should again occur before TDC. Simultaneously under side of the piston is drawing in a charge through a springloaded non-return inlet valve. 2. Power stroke: The burning mixture raises the temperature and pressure in the cylinder, and forces the piston down. The downward motion of the piston also compresses the charge in the crankcase. As the piston approaches the end of its stroke the exhaust port is uncovered and blowdown occurs. When the piston is at BDC the transfer port is also uncovered, and the compressed charge in the crankcase expands into the cylinder. Some of the remaining exhaust gases are displaced by the fresh charge; because of the flow mechanism this is called loop scavenging'. As the piston travels up the cylinder, the piston closes the first transfer port, and then the exhaust port is closed.
Performance of I.C.Engines
Indicated thermal efficiency (t): Indicated thermal efficiency is the ratio of energy in the indicated power to the fuel energy.
Brake thermal efficiency (bth): A measure of overall efficiency of the engine is given by the brake thermal efficiency. Brake thermal efficiency is the ratio of energy in the brake power to the fuel energy.
bth (%) =
Mechanical efficiency (m): Mechanical efficiency is the ratio of brake horse power (delivered power) to the indicated horsepower (power provided to the piston).
m = BrakePower / IndicatedPower
and Frictional power = Indicated power Brake power Following figure gives diagrammatic representation of various efficiencies, Energy lost in exhaust, coolant, and radiation
Energy lost in friction, pumping etc. Energy in fuel (A) IP (B) BP (C)
17-06-2008
Im224
Page 13
Apex Innovations
Indicated thermal efficiency = B/A Brake thermal efficiency = C/A Mechanical efficiency = C/B Volumetric efficiency (v): The engine output is limited by the maximum amount of air that can be taken in during the suction stroke, because only a certain amount of fuel can be burned effectively with a given quantity of air. Volumetric efficiency is an indication of the breathing ability of the engine and is defined as the ratio of the air actually induced at ambient conditions to the swept volume of the engine. In practice the engine does not induce a complete cylinder full of air on each stroke, and it is convenient to define volumetric efficiency as: v (%) = Mass of air consumed -------------------------------------------------------------------------mass of flow of air to fill swept volume at atmospheric conditions
v (%) =
Where n= 1 for 2 stroke engine and n= 2 for 4 stroke engine. Air flow: For air consumption measurement air box with orifice is used.
17-06-2008
Im224
Page 14
Apex Innovations angular velocity. Thus, the measurement of power involves the measurement of force (or torque) as well as speed. The power developed by an engine at the output shaft is called brake power and is given by Power = NT/60,000 in kW where T= torque in Nm = WR W = 9.81 * Net mass applied in kg. R= Radius in m N is speed in RPM Mean effective pressure and torque: Mean effective pressure is defined as a hypothetical pressure, which is thought to be acting on the piston throughout the power stroke. Power in kW = (Pm LAN/n 100)/60 in bar where Pm = mean effective pressure L = length of the stroke in m A = area of the piston in m2 N = Rotational speed of engine RPM n= number of revolutions required to complete one engine cycle n= 1 (for two stroke engine) n= 2 (for four stroke engine) Thus we can see that for a given engine the power output can be measured in terms of mean effective pressure. If the mean effective pressure is based on brake power it is called brake mean effective pressure (BMEP) and if based on indicated power it is called indicated mean effective pressure (IMEP).
BMEP(bar ) =
IMEP(bar ) =
Similarly, the friction means effective pressure (FMEP) can be defined as FMEP= IMEP BMEP
Basic measurements
The basic measurements, which usually should be undertaken to evaluate the performance of an engine on almost all tests, are the following:
1 Measurement of speed
Following different speed measuring devices are used for speed measurement. 1 Photoelectric/Inductive proximity pickup with speed indicator 2 Rotary encoder
I) Volumetric method: The fuel consumed by an engine is measured by determining the volume flow of the fuel in a given time interval and multiplying it by the specific gravity of fuel. Generally a glass burette having graduations in ml is used for volume flow measurement. Time taken by the engine to consume this volume is measured by stopwatch. II) Gravimetric method: In this method the time to consume a given weight of the fuel is measured. Differential pressure transmitters working on hydrostatic head principles can used for fuel consumption measurement.
Air box method: In IC engines, as the air flow is pulsating, for satisfactory measurement of air consumption an air box of suitable volume is fitted with orifice.
17-06-2008
Im224
Page 15
Apex Innovations The air box is used for damping out the pulsations. The differential pressure across the orifice is measured by manometer and pressure transmitter.
Measurement of BP involves determination of the torque and angular speed of the engine output shaft. This torque-measuring device is called a dynamometer. The dynamometers used are of following types: I) Rope brake dynamometer: It consists of a number of turns of rope wound around the rotating drum attached to the output shaft. One side of the rope is connected to a spring balance and the other to a loading device. The power is absorbed in friction between the rope and the drum. The drum therefore requires cooling. Brake power = DN (W-S)/60,000 in kW where D is the brake drum diameter, W is the weight and S is the spring scale reading. II) Hydraulic dynamometer: Hydraulic dynamometer works on the principal of dissipating the power in fluid friction. It consists of an inner rotating member or impeller coupled to output shaft of the engine. This impeller rotates in a casing, due to the centrifugal force developed, tends to revolve with impeller, but is resisted by torque arm supporting the balance weight. The frictional forces between the impeller and the fluid are measured by the spring-balance fitted on the casing. Heat developed due to dissipation of power is carried away by a continuous supply of the working fluid usually water. The output (power absorbed) can be controlled by varying the quantity of water circulating in the vortex of the rotor and stator elements. This is achieved by a moving sluice gate in the dynamometer casing. III) Eddy current dynamometer: It consists of a stator on which are fitted a number of electromagnets and a rotor disc and coupled to the output shaft of the engine. When rotor rotates eddy currents are produced in the stator due to magnetic flux set up by the passage of field current in the electromagnets. These eddy currents oppose the rotor motion, thus loading the engine. These eddy currents are dissipated in producing heat so that this type of dynamometer needs cooling arrangement. A moment arm measures the torque. Regulating the current in electromagnets controls the load. Note: While using with variable speed engines sometimes in certain speed zone the dynamometer operating line are nearly parallel with engine operating lines which result in poor stability.
17-06-2008
Im224
Page 16
Apex Innovations
The figure shows crank-slider mechanism. The piston pin position is given by
x = r cos + l cos
x = r cos + l r
{1 (r l )
sin 2
cos = 1 sin 2
The binomial theorem can be used to expand the square root term:
]}
.1
sin 2 = 1 / 2 1 / 2 cos 2
.2 Substituting the results from equation 2 in to equation 1 gives
case it is acceptable to neglect the (r / l ) terms, as inspection of above equation shows that these terms will be at least an order of magnitude smaller than
4
x = r cos + l / r 1 1 (r / l ) 2 (1 / 2 1 / 2 cos 2 ) 1 8 (r / l ) 4 (3 / 8 1 / 2 cos 2 + 1 / 8 cos 4 ) + ... 2 2 The geometry of the engine is such that (r / l ) is invariably less than 0.1, in which
]}
(r / l )2 terms.
x = r cos + l / r 1 1 ( r / l ) 2 (1 / 2 1 / 2 cos 2 ) 2
]}
Where r =crankshaft throw and l = connecting rod length. Calculate x using above equation; then (l + r x) shall give distance traversed by piston from its top most position at any angle II) Morse test: It is applicable to multi-cylinder engines. The engine is run at desired speed and output is noted. Then combustion in one of the cylinders is stopped by short circuiting spark plug or by cutting off the fuel supply. Under this condition other cylinders motor this cylinder. The output is measured after adjusting load on the engine to keep speed constant at original value. The difference in output is measure of the indicated power of cut-out cylinder. Thus for each cylinder indicated power is obtained to find out total indicated power.
VCR Engines
The standard available engines (with fixed compression ratio) can be modified by providing additional variable combustion space. This is done by welding a long hollow sleeve with internal threads to the engine head. A threaded plug is inserted in the sleeve to vary the combustion chamber volume. With this method the compression ratio can be changed within designed range.
17-06-2008
Im224
Page 17
Apex Innovations
Calculations
BP =
2NT 60 x1000 2N (WxR) = 60000 0.785 xRPMx(Wx9.81) xArmlength = 60000 TxN BHP = 75x60
BMEP =
n = 2 for 4 stroke n = 1 for 2 stroke
Indicated power (kw) :From PV diagram X scale (volume) 1cm = ..m3 Y scale (pressure) 1cm = ..bar Area of PV diagram = ..cm2
workdone / cycle / cyl ( Nm) = AreaofPVdiagram Xscalefactor Yscalefactor 100000 workdone / cycle / cyl ( N / n) NoOfCyl IP = 60 1000
Indicated mean effective pressure (bar):
IMEP =
Frictional power (kw):
BSFC =
FuelflowInkg / hr BP
BThEff =
17-06-2008
Apex Innovations
BThEff =
IThEff =
IThEff =
MechEff =
Air flow (Kg/hr):
VolEff = =
A/ F =
a)
AirFlow FuelFlow
17-06-2008
Im224
Page 19
Apex Innovations
C P ex =
Where, Cpex
F 4 C PW (T 4 T 3) ..KJ / Kg 0 k ( F1 + F 2) (T 5 T 6)
Specific heat of exhaust gas Specific heat of water Fuel consumption Air consumption Calorimeter water flow Calorimeter water inlet temperature Calorimeter water outlet temperature Exhaust gas to calorimeter inlet temp. Exhaust gas from calorimeter outlet temp. kJ/kg0K kJ/kg0K kg/hr kg/hr kg/hr 0 K 0 K 0 K 0 K
Cpw F1 F2 F4 T3 T4 T5 T6
17-06-2008
Im224
Page 20
Apex Innovations
Software
Installing DAQMX Software for Windows XP
Insert NI DAQMX software CD 1 of 2
17-06-2008
Im224
Page 21
Apex Innovations
Click Next.
Click Next
17-06-2008
Im224
Page 22
Apex Innovations
Click Next
17-06-2008
Im224
Page 23
Apex Innovations
Click Next
Insert Disk 2 of 2
17-06-2008
Im224
Page 24
Apex Innovations
Click Next
Click On Restart
17-06-2008
Im224
Page 25
Apex Innovations
17-06-2008
Im224
Page 26
Apex Innovations
6. Click Next
6. Click Finish
17-06-2008
Im224
Page 27
Apex Innovations (temperatures and load) with the values displayed on multipoint digital voltmeter provided on control panel. If some problem is noticed at this stage resolve it before starting the engine. Start the engine and observe the values displayed on the screen. A typical screen is shown below:
Wait for @ 3 minutes to achieve steady state. Change the fuel cock to measuring and press Log for data logging.
After one minute software will prompt for file name. Enter the file name (file name should not start with numeric character).
17-06-2008
Im224
Page 28
Apex Innovations
17-06-2008
Im224
Page 29
Apex Innovations
: 0-1200 C
17-06-2008
Im224
Page 30
Apex Innovations Air flow transmitter Fuel flow DP transmitter Load cell Sensor signal range (input for interface) Cylinder pressure transducer : : : : : (-)250 - 0 mm WC 0-500 mm WC 0-50 kg 1-5 V 0-345.5 bar
17-06-2008
Im224
Page 31
Apex Innovations
1 TDC 5
Compression
Expansion
Induction
1 Inlet valve opens before TDC : 4.5 0 2 Inlet valve closes after BDC : 35.5 0 3 Fuel injection starts before TDC : 23 0 4 Exhaust valve opens before BDC : 35.5 0 0 5 Exhaust valve closes after TDC : 4.5
Exhaust
2 BDC
Procedure Switch off the electric supply of the panel box Open the cover on the engine head to see the rocker arms. Lift up the decompression lever.
17-06-2008
Im224
Page 32
Apex Innovations Note the TDC mark provided on the flywheel. (Also refer the valve timing diagram). Slowly rotate the flywheel in clockwise direction looking from dynamometer side. Identify inlet valve and exhaust valve rocker arms Observe the movement of rocker arms and understand the valve opening and closing. To observe fuel injection it is necessary to remove fuel injector.
17-06-2008
Im224
Page 33
Apex Innovations
Wiring diagram
17-06-2008
Im224
Page 34
Apex Innovations
Components manuals
Model Make Pvt. Ltd. Flow Rate Max. Packing/Gaskets Measuring tube Float Cover Accuracy Range ability Scale length Max. Temp. Connection
Technical specifications
4000 to 40000 Lph Neoprene Borosilicate glass 316SS Glass +/-2% full flow 10:1 175-200mm. 2000C Flanged and Threaded, Vertical
The rotameter valves must be opened slowly and carefully to adjust the desired flow rate. A sudden jumping of the float, which may cause damage to the measuring tube, must be avoided.
Principle of operation
Fig.1 Edge
The upper edge of the float as shown in fig. 1 indicates the rate of flow. For alignment a line marked R.P. is provided on the scale which should coincide with the red line provided on measuring tube at the bottom.
Maintenance
When the measuring tube and float become dirty it is necessary to remove the tube and clean it with a soft brush, trichloroethylene or compressed air.
Shut off the flow. Remove the front and rear covers. Unscrew the gland adjusting screws, and push the gland upwards incase of bottom gland and downwards incase of top gland. Then remove the glass by turning it to
17-06-2008
Im224
Page 35
Apex Innovations and fro. Care should be taken, not to drop down the glands. Float or float retainers. The indicating edge of the float should not be damaged. Normally the old gland packing is replaced by new ones while fitting back the measuring tube. Put the glands first in their position and then put the packing on the tube. Insert the tube in its place. Push the glands downwards and upwards respectively and fix them with the gland adjusting screws. Tighten the gland adjusting screws evenly till the gap between the gland and the bottom plate is approximately 1mm. In case, after putting the loflometer into operation, still there is leakage, then tighten the gland adjusting screw till the leakage stops. Fix the scale, considering the remark given in the test report. Fix the front and rear covers.
Troubleshooting
Problem Leakage on glands Showing high/low flow rate than expected Showing correct reading initially but starts showing high reading after few days Showing correct reading initially but starts showing high reading after some months. Fluctuation of float Frequent breakage of glass tube
Check Replace gland packing Consult manufacturers Replace float Incase of gases, check also leakage Clean the rotameter by suitable solvent or soft brush Maintain operating pressure as mentioned in test report. Use loflometer to accommodate correct flow rate. Maintain operating pressure below pressure rating of the tube. Check piping layout.
Manufacturers address
If you need any additional details, spares or service support for this unit you may directly communicate to the manufacturer / Dealer / Indian Supplier. Eureka Industrial Equipments Pvt. Ltd. 17/20, Royal Chambers, Paud Road, Pune 411 038. Email: eureka.equip@gems.vsnl.net.in
17-06-2008
Im224
Page 36
Apex Innovations
Load indicator
17-06-2008
Im224
Page 37
Apex Innovations
17-06-2008
Im224
Page 38
Apex Innovations
17-06-2008
Im224
Page 39
Apex Innovations
17-06-2008
Im224
Page 40
Apex Innovations
Manufacturers address
If you need any additional details, spares or service support for this unit you may directly communicate to the manufacturer / Dealer / Indian Supplier. WIKA Instruments Ltd. Garmany. Web: www.wika.de Wika Instruments India Pvt. Ltd. Plot No. 40, GatNo. 94+100, high Cliff Ind. Estate, Village Kesnand, Pune 412207
17-06-2008
Im224
Page 41
Apex Innovations
Load cell
Introduction
Load cell are suitable use for static & dynamic weighing, bin/hopper weighing, force measurement, scales and electro-mechanical conversion kit. Constructed body of special high alloy steel. Approved for group I, IIA, IIB, & IIC applications and meets temperature class T4.
Make Model Type Capacity Mounting thread Full scale output (mV/V) Tolerance on output (FSO) Zero balance (FSO) Non-linearity (FSO) Hysteresis (FSO) Non-repeatability Creep (FSO) in 30 min Operating temperature range Rated excitation Maximum excitation Bridge resistance Insulation resistance Span / 0C (of load) Zero / 0C (of FSO) Combined error (FSO) Safe overload (FSO) Ultimate overload (FSO) Protection class Overall dimensions Weight
Technical specifications
Sensortronics 60001 S Beam, Universal 0 50Kg M10 x 1.25mm 3.00 +/-0.25% +/-0.1mV/V <+/-0.025% <+/-0.020% <+/-0.010% <+/-0.020% -200C to +700C 10V AC/DC 15V AC/DC 350 Ohms (Nominal) >1000 Meg ohm @ 50VDC +/-0.001% +/-0.002% <+/-0.025% 150% 300% IP 67 51 L x 20 W x 76 H mm 380 gm
Manufacturers address
If you need any additional details, spares or service support for this unit you may directly communicate to the manufacturer / Dealer / Indian Supplier. Sensortronics Sanmar Ltd. 38/2A, Old Mahabalipuram Road, Perungudi, Chennai 600 096. E-mail: KBS@SANMARGROUP.com
17-06-2008
Im224
Page 42
Apex Innovations
Encoder
Technical specifications
Make Model Supply voltage Output PPR Outlet Cable type Encoder Diameter Shaft size Weight Kubeler 8.3700.1321.0360 5-30VDC Push pull (AA,BB,OO) 360 axial Dia. 37, Dia.6mm x length12mm 120 gm
If you need any additional details, spares or service support for this unit you may directly communicate to the manufacturer / Dealer / Indian Supplier. Kuebler Germany Indian supplier: Rajdeep Automation Pvt. Ltd. Survey No. 143, 3rd floor, Sinhgad Road, Vadgaon Dhayari, Pune 411 041.
Manufacturers address
Piezo sensor
These miniature sensor series are intended for general purpose pressure measurements. Models HSM111A22 and M108A02 are designed for applications where acceleration compensation is not required. Other applications for these sensors include the monitoring of pulsating pneumatic and hydraulic pressures in R & D and industrial applications. This versatile transducer series is designed for dynamic measurement of compression, combustion, explosion, pulsation, cavitations, blast, pneumatic, hydraulic, fluidic and other such pressures.
Introduction
Technical specifications
Sensor name Make Model Range, FS (5V output) Useful range (10V output) Maximum pressure Resolution Sensitivity Resonant frequency Rise time Discharge time constant Linearity (zero based BSL) Output impedance
Hydraulic pressure transducer With built in amplifier PCB Piezotronics, INC. M108A02 10000 psi 20000 psi 50000 psi 0.4 psi 0.5 mV/psi 300 kHz 2 s 1000 s 2% 100 ohms
17-06-2008
Im224
Page 43
Apex Innovations Acceleration sensitivity Temperature coefficient Temperature range Vibration Shock Sealing Excitation (Constant current) Voltage to current regulator Sensing geometry Sensing element Housing material Diaphragm Electrical connector Mounting thread Weight Cable model 0.01 psi/g 0.03 %/0F -100 to +250 0F 2000 g peak 20000 g peak Hermetic welded 2 to 20 mA +18 to 28 VDC Compression Quartz C-300 C-300 10-32 coaxial jack M10 x 0.1pitch 12 gm 002C20 white coaxial cable
Technical specifications
Sensor name Make Model Range, FS (5V output) Useful range (10V output) Maximum pressure Resolution Sensitivity Resonant frequency Rise time Discharge time constant Low frequency response (-5%) Linearity (Best straight line) Output polarity Output impedance Output bias Acceleration sensitivity Temperature coefficient Temperature range Flash temperature Vibration / Shock Ground isolation Excitation (Constant current) Voltage to current regulator Sensing geometry Sensing element Housing material Diaphragm Sealing Electric connector Mounting thread Weight (with clamp nut) Cable model
Dynamic pressure transducer With built in amplifier PCB Piezotronics, INC. M111A22 5000 psi 10000 psi 15000 psi 0.1 psi 1 mV/psi 400 kHz 2 s 500 s 0.001 Hz 2% Positive 100 ohms 8-14 volt 0.002 psi/g 0.03 %/0F -100 to +275 0F 3000 0F 2000 / 20000 g peak No (2) 2 to 20 mA +18 to 28 VDC Compression Quartz 17.4 SS Invar Welded hermetic 10-32 coaxial jack M7 x 0.75 pitch 6 gm 002C20 white coaxial cable
17-06-2008
Im224
Page 44
Apex Innovations
Principle of operation
1. Hydraulic pressure transducer: Unlike conventional diaphragm type sensors, the 108A is pressure sensitive over the entire frontal area. For this reason, extra care should be exercised to avoid bottoming in mounting hole when recessed mounted and especially when mounting into existing mounting ports. A torque wrench should be used to monitor the mounting torque valve when installing the series 108A. Mounting in existing recessed ports: Before installing the sensor in previously used mounting ports, clean off residue from previous tests. This can be accomplished by hand reaming the required size reamer. During prolonged testing, should waveform distortion occur, Remove sensor and remove reside. Flash Temperature Effects: The ceramic coating on the diaphragm of these sensors should render the flash thermal effect insignificant in most cases, especially when recessed mounted. However, if more protection from flash thermal effects is required with the recessed mount, the passage can be filled with silicone grease (DC-4 or equivalent). Several layers of black vinyl electrical tape directly on the diaphragm have proven effective in many cases. Flash temperature effects are usually longer term and will show up as baseline shift long after the event to be measured has passed. For flush mount installations, a silicone rubber coating approximately 0.010 thick can be effective. General electric RTV type 106 silicone rubbers are recommended. 2. Dynamic pressure transducer: It is necessary only to supply the sensor with a 2 to 20 mA constant current at +20 to +30 VDC through a current regulating diode or equivalent circuit. Most of the signal conditioners manufactured by PCB have adjustable current features allowing a choice of input currents from 2 to 20 mA. In general, for lowest noise (best resolution), choose the lower current ranges. When driving long cables (to several thousand feet), use the higher current, up to 20 mA maximum. Switch power on and observe reading of bias monitoring voltmeter on front panel of power unit. Flash Temperature Protection Where flash temperatures such as those generated by combustion processes are present, it may be necessary to thermally insulate the diaphragm to minimize spurious signals generated by these effects. Common black vinyl electrical tape has been found to be an effective insulating material in many cases. One or more layers may be used across the end of the diaphragm without affecting response or sensitivity. A silicone rubber coating approximately 0.010 inches thick has also been proven effective in many applications. General electric RTV type 106 silicone rubbers are recommended. Low Frequency Response The discharge time constant of the sensor. If AC coupled at the power unit, the coupling time constant. Depending upon the sensors built-in discharge time constant, repetitive output signals slowly or rapidly move toward a stable condition where the average signal level corresponds to a zero voltage position. In this position, the area contained by the signal above zero is equalized with the area below zero. Such output signal behavior is typical of an AC-coupled system. Since the signal output from the sensor is inherently AC coupled, any static pressure influence applied to the unit will decay away according to the nature of the systems discharge time constant.
17-06-2008
Im224
Page 45
Apex Innovations
Troubleshooting
Problem No signal Sensor damaged or ceases to operate Check Remove sensor and clean by dampened cloth Return the equipment to company for repair
Calibration
1. Piezoelectric sensors are dynamic devices, but static calibration techniques can be employed if discharge time constants are sufficiently long. Generally, static calibration methods are not employed when testing sensors with a discharge time constant that is less than several hundred seconds. 2. Direct couple the sensor to the DVM readout using a T-connector from the Xducer jack or use the model 484B in the calibrate mode. 3. Apply pressure with a dead weight tester and take reading quickly. Release pressure after each calibration point. 4. For shorter TC series, rapid step functions of pressure are generated by a pneumatic pressure pulse calibrator or dead weight tester and readout is by recorder or storage oscilloscope.
Manufacturers address
If you need any additional details, spares or service support for this unit you may directly communicate to the manufacturer / Dealer / Indian Supplier. PCB Piezotronics, Inc. 3425 Walden Avenue, Depew, New York 14043-2495. E-mail: pressure@pcb.com Web: www.pcb.com Indian supplier: Structural soluction (India) Pvt. Ltd.
Technical specifications
AG10 Saj Test Plant Pvt. Ltd. Cardon shaft model 1260 type A 1.6bar 160 23 0.77/0.63 11.5 60 5.0
17-06-2008
Im224
Page 46
Apex Innovations Cold resistance ohms Speed max. Load Bolt size Weight Model Make End flanges both side Water inlet Minimum kPa Pressure lbf/in2 Air gap mm Torque Nm Hot coil voltage max. Continuous current amps Cold resistance ohms Speed max. Load Bolt size Weight Model Make End flanges both side Water inlet Minimum kPa Pressure lbf/in2 Air gap mm Torque Nm Hot coil voltage max. Continuous current amps Cold resistance ohms Speed max. Load Bolt size Weight 9.8 10000rpm 3.5kg M12 x 1.75 130kg AG20 Saj Test Plant Pvt. Ltd. Cardon shaft model 1260 type A 1.6bar 160 23 0.88/0.72 11.5 60 5.0 9.8 10000rpm 5.0Kg M12 x 1.75 220Kg AG80 Saj Test Plant Pvt. Ltd. Cardon shaft model 1260 type A 1.0bar 100 14.5 1.047/0.855 11.5 75 5.0 12.8 9000rpm 40kg M16 x 2.00 330kg
Technical specifications
Technical specifications
1. The dynamometer unit comprises basically a rotor mounted on a shaft running in bearings which rotates within a casing supported in ball bearing trunnions which form part of the bed plate of the machine. 2. Secured in the casing are two field coils connected in series. When these coils are supplied with a direct current (DC) a magnetic field is created in the casing across the air gap at either side of the rotor. When the rotor turns in this magnetic field, eddy currents are induced creating a breaking effect between the rotor and casing. The rotational torque exerted on the casing is measured by a strain gauge load cell incorporated in the restraining linkage between the casing and dynamometer bed plate. 3. To prevent overheating of the dynamometer a water supply pressurized to minimum indicated in specification is connected to a flanged inlet on the bed plate. Water passes from the inlet to the casing via a flexible connection; permitting
Principle of operation
17-06-2008
Im224
Page 47
Apex Innovations movement of the casing. Water passes through loss (Grooved) plates in the casing positioned either side of the rotor and absorbs the heat generated. 4. Heated water discharges from the casing through a flexible connection to an outlet flange on the bed plate. An orifice plate is fitted at the bed plate outlet and a DIFFERENTIAL pressure switch is connected to water passages either side of the plate. The switch detects a COOLANT FLOW and will function with a free discharge or under back pressure.
Troubleshooting
Problem Calibration of dynamometer not coming in accuracy limit Check Remove the obstruction for the free movement of casing Calibrate the weights from authorized source. Maintain constant water flow Clean & lubricate properly with grease Bearings clean & refit properly Load cell link tighten properly Clean & refit trunnion bearings Dynamometer foundation bolts tighten properly Arrest engine vibrations Cardon shaft cover secure properly Align guard properly Replace rotor if warped Replace main bearing Check correct water flow De-scale with suitable solution Clear off water passages Grease with proper brand Remove excess grease & avoid over grease Use specified grease and do not mix two types of grease Clear the drain Replace the bearings Replace shaft & coupling Replace bearings Replace rotor / loss plates after checking Replace casing o rings Loss plates bolts tighten properly Replace loss plate o rings Casing plugs tighten properly Replace pipe o rings Pressure switch connection tighten properly
Calibration
1. It is important to note that the torque applied during calibration is: Nm = applied weight (kg) x g x arm length (m) S.I. units Lbf.ft = applied weight (ibf) x arm length (ft) Imperial units Kg.m = applied weight (kg) x arm length (m) MKS units
17-06-2008
Im224
Page 48
Apex Innovations 2. Switch on the mains electrical supply to the control equipment at least 30 minutes before starting the calibration procedure. 3. Turn on the water supply and allow water to flow through the dynamometer at normal operating pressure. 4. With no load applied to the dynamometer ensure that the load indicator on the control unit reads ZERO if necessary adjust the control equipment until ZERO is indicated.
Operation
1. New dynamometers are run in before delivery to ensure that all components run smoothly and grease is evently distributed within the shaft bearings. 2. The dynamometer has been calibrated the power developed by the engine on test may be calculated using the following formula:
3. The dynamometer will be calibrated in either Imperial or S.I. units or MKS as specified. Power =
Torque( Nm) xSpeed ( Radians / sec .) inS .I .units 1000 Torque(lbfft ) xSpeed ( Radians / sec .) Power (hp) = in.imperialunits 550
Power (kW) =
Where N = Shaft speed in rev/min W = Torque (Indicated on torque indicator) K = Constant dependant on units of power and torque
WN k
Manufacturers address
If you need any additional details, spares or service support for this unit you may directly communicate to the manufacturer / Dealer / Indian Supplier. Saj Test Plant Pvt. Ltd. 72-76, Mundhwa, Pune Cantonment, Pune 411 036. Email:sajdyno@vsnl.com
17-06-2008
Im224
Page 49
Apex Innovations
Load/Temperature indicator
17-06-2008
Im224
Page 50
Apex Innovations
17-06-2008
Im224
Page 51
Apex Innovations
Model EJA110A-DMS5A-92NN Make Yokogawa Output signal 4 20mA DC with digital communication (Linear) Measurement span 1 to 100kPa (100 to 10000mmH2O) Calibration range 0 200, 0 500 mmH2O Wetted parts material Body SCS14A, Capsule SUS316L Process connections without process connector (1/4BSP body connection) Bolts and nuts material SCM 435 Installation Horizontal impulse piping left side high pressure Electrical connection 1/2NPT female Cover O rings Buna-N Supply 10 to 24VDC Process temperature limit -40 to 120 0C Housing Weather proof Weight 3.9Kg
Technical specifications
Manufacturers address
If you need any additional details, spares or service support for this unit you may directly communicate to the manufacturer / Dealer / Indian Supplier. Yokogawa Electrical Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750, Japan. Indian supplier: Yokogawa Blue Star Ltd. 40/4 Lavelle Road, Bangalore 560 001.