Sei sulla pagina 1di 1

Hydro-Flo Technologies, Inc.

The Art and Science... of Wastewater Treatment

Company Location USER INPUTS IN YELLOW DESIGN FLOW RATE (IN GPM) TEMPERATURE (IN DEGREES F) SPECIFIC GRAVITY OF THE OIL (IN G/CM) OIL DROPLET SIZE (IN MICRONS) MEDIA SPACING ( 0.5 0.75 or 1.20 )

150.000 60.000 0.900 30.000 0.750

For more detailed information go to www.HydroFloTech.com HOPPER BOTTOM SKIMMER COVERS AUGER MODEL NUMBER 0.000 0.000 0.000 0.000 LIST OF OPTIONS MARK 0 FOR NO 1 FOR YES

132 - FB - NS - NC - NA

Call 630-762-0380 to talk to a Hydro-Flo application engineer OUTPUTS IN BLUE DENSITY OF THE WATER (IN G/CM) VISCISITY (IN POISE) RISE RATE OF OIL DROPLET (IN GPM/FT) PROJECTED SURFACE AREA (IN FT/FT) REQUIRED MEDIA VOLUME (IN FT) HORIZONTAL SERAPATOR AREA IN FT REQUIRED TO ACHIEVE DESIRED OIL REMOVAL EFFICENCY

1.00 0.0113 0.0632 21 112.96

2372

Use the formula below if you know the degrees API but not the specific gravity of the product to be removed Conversion from Degrees API to Specific Gravity: Formula: Sw = (141.5 / (API + 131.5)) DEGREES API 35.000 SPECIFIC GRAVITY 0.84984985 Formula: Qm / (AH * 7.48) = (j2 * 1.072 x 10 6) (Sw - So) / m Qm = design flow, in ft3 AH = horizontal separator area, in ft2 j = oil droplet diameter in microns Sw = specific gravity of the wastewater So = specific gravity of the wastewaters oil phase m = wastewaters absolute (dynamic viscosity, in poise)