Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Doc No. SR. NO. : M-1600 Application Size Pressure Class 300 900 900 1500 600 150 600 1500 900 900 600 300 300 300 150 150 150 300 600 600 Operating Pressure (kg/cm2)(g) 15 115 115 70 13 7 13 70 119 115 18 13 13 13 7 7 7 13 10 10
FEED CONTROL VALVES 1 FEED REGULATING VALVE IN HP BFP DISCH LINE 2" 2 FEED REGULATING VALVE IN HP BFP DISCH LINE-FULL LOAD 3" 3 FEED REGULATING VALVE IN HP BFP DISCH LINE-LOW LOAD 2" SPRAY VALVES 1 HP STEAM BYPASS VALVES 6" 2 HP BYPASS SPRAY VALVES 2" 3 LP STEAM BYPASS VALVES 8" 4 LP BYPASS SPRAY VALVES 1" PRDS VALVES 1 PRESSURE RED VALVE IN HP LINE TO AUX HEADER 2" 2 PRDS SPRAY CONTROL VALVES 1" FEED PUMP RECIRCULATION VALVES 1 RECIRCULATION VALVE FOR HP BFP 1.5" 2 RECIRCULATION VALVE FOR LP BFP 1" HEATER DRAIN VALVES & CONDENSATE SYSTEM VALVES 1 MAIN CONDENSATE CONTROL VALVES 6" 2 MIN FLOW RECIRCULATION CONTROL VALVE 2" 3 EXCESS RETURN CONTROL VALVES 2" 4 DEAERATOR OVERFLOW TO DM STORAGE TANK 3" 5 PRESSURE REDUCING VALVE TO DEAERATOR 3" 6 PRESSURE REDUCING VALVE TO DEAERATOR 8" 7 REHEATER INLET CONTROL VALVE 4" 8 NORMAL MAKE UP VALVE 1" 9 DUMP MAKE UP VALVE 2"
Operating Temp (oC) 121 121 121 4890 50 147 50 480 121 122 122 48 48 48 120 147 147 118 40 40
FEED CONTROL VALVES 1 FULL LOAD FEED WATER CONTROL(MAIN) 2 FULL LOAD FEED WATER CONTROL(BYPASS) 3 LOW LOAD FEED WATER CONTROL SPRAY & SOOT BLOWER VALVES 1 2 3 4 5 6 7 8 1 2 3 4 5 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SH SPRAY STAGE I BLOCK SH STAGE I SPRAY CONTROL SH SPRAY STAGE II BLOCK SH STAGE II SPRAY CONTROL RH SPRAY MAIN BLOCK RH BRANCH BLOCK RH SPRAY CONTROL SOOT BLOWER STEAM PR REDUCING VALVE
12"X8" 12"X8" 6"X4" 6"X4" 2.5" 3" 1.5" 2.5" 1.5" 1.5" 2"
PRDS VALVES AUX PRDS 100% STEAM CONTROL VALVE 6"X3" 2500 SPL AUX PRDS 10% STEAM CONTROL VALVE 2" 2500 SPL AUX PRDS 100% SPRAY FLOW CONTROL VALVE 1.5" 2500 AUX PRDS 10% SPRAY FLOW CONTROL VALVE 1" 2500 BLOCK VALVE ON SPRAY WATER TO AUX PRDS 2" 2500 FEED PUMP RECIRCULATION VALVE FEED PUMP MINIMUM RECIRCULATION VALVES 4"X2" 2500 HEATER DRAIN VALVES & CONDENSATE SYSTEM VALVES PEGGING STEAM AUX STEAM HEADER TO DEAERATOR 6" 300 PEGGING STEAM FROM CRH TO DEAERATOR 10" 600 HPH-6 NORMAL DRAIN TO HPH-5 3" 600 HPH-6 ALT DRAIN TO DEAERATOR 3" 600 HPH-6 ALT DRAIN TO HP FLASH TANK 3' 600 HPH-5 ALT DRAIN TO DEAERATOR 4" 300 HPH-5 ALT DRAIN TO HP FLASH TANK 4" 300 LPH-3 NORMAL DRAIN TO LPH-2 3" 300 LPH-3 ALT DRAIN TO LP FLASH TANK 4" 300 LPH-2 NORMAL DRAIN TO LPH-1 8" 300 LPH-2 ALT DRAIN TO LP FLASH TANK 8" 300 DEAERATOR OVERFLOW TO LP FLASH TANK 10" 300 MAIN CONDENSATE CONTROL 10" 300 EXCESS CONDENSATE DUMP CONTROL 6"X4" 300 CONDENSATE EXTRACT PUMP MIN RECIRCULATION VALVE 6" 300 HP DRAINS FLASH TANK SPRAY 1" 300
17 DM MAKE UP TO HOT WELL-LOW CAPACITY 18 DM MAKE UP TO HOT WELL-HIGH CAPACITY 19 CONDENSATE FOR VALVE GLAND SEALING
10 10 25
50 50 55
1 2 3 4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
FEED CONTROL VALVES FULL LOAD FEED WATER CONTROL(MAIN) 14"X10" FULL LOAD FEED WATER CONTROL(BYPASS) 14"X10" LOW LOAD FEED WATER CONTROL 6"X4" FEED REGULATING VALVE IN HP BFP DISCH LINE-FULL LOAD SPRAY & SOOT BLOWER VALVES SH SPRAY STAGE I BLOCK 6" SH STAGE I SPRAY CONTROL 2.5" SH SPRAY STAGE Ii BLOCK 3" SH STAGE Ii SPRAY CONTROL 1.5" RH SPRAY MAIN BLOCK 3" RH BRANCH BLOCK 2" RH SPRAY CONTROL 2" SOOT BLOWER STEAM PR REDUCING VALVE 2" PRDS VALVES MS PRDS SPRAY CONTROL 6"X4" MS PRDS SPRAY CONTROL 1.5" MS PRDS SPRAY CONTROL 1.5" CRH STEAM PRDS 2.5" CRH PRDS SPRAY CONTROL 1" CRH PRDS SPRAY CONTROL 1" FEED PUMP RECIRCULATION VALVE FEED PUMP MINIMUM RECIRCULATION VALVES 4"X2" HEATER DRAIN VALVES & CONDENSATE SYSTEM VALVES PEGGING STEAM AUX STEAM HEADER TO DEAERATOR 8" PEGGING STEAM FROM CRH TO DEAERATOR 10" HPH-6 NORMAL DRAIN TO HPH-5 3" HPH-6 ALT DRAIN TO DEAERATOR 3" HPH-6 ALT DRAIN TO HP FLASH TANK 3' HPH-5 ALT DRAIN TO DEAERATOR 4" HPH-5 ALT DRAIN TO HP FLASH TANK 4" LPH-3 NORMAL DRAIN TO LPH-2 4" LPH-3 ALT DRAIN TO LP FLASH TANK 4" LPH-2 NORMAL DRAIN TO LPH-1 8" LPH-2 ALT DRAIN TO LP FLASH TANK 8" DEAERATOR OVERFLOW TO LP FLASH TANK 3" MAIN CONDENSATE CONTROL 12" CONDENSATE EXTRACT PUMP MIN RECIRCULATION VALVE 3" EXCESS CONDENSATE DUMP CONTROL 6"X3" HP DRAINS FLASH TANK SPRAY 1" EMERGENCY MAKE UP TO CONDENSATE HOT WELL 3" DM MAKE UP TO HOT WELL-LOW CAPACITY 3" DM MAKE UP TO HOT WELL-HIGH CAPACITY 4" EMERGENCY DM MAKE UP TO DEAERATOR EXCESS CONDENSATE RETURN TO CST CONDENSATE FOR VALVE GLAND SEALING
L VALVES
Pressure Class 2500 2500 2500 Operating Pressure (kg/cm2)(g) 330 330 330 187 262 182 262 182 282 282 182 182 169 267 267 48 267 267 260 14 48 48 48 48 20 20 8 8 8 8 11 27 27 27 30 8 8 8 4.8 Operating Temp (oC) 248 248 248 138 260 260 350 350 350 350 350 450 545 170 170 360 170 170 250 220 360 215 215 215 175 175 130 130 105 105 170 55 55 55 55 55 40 40 45
S 2500 2500 2500 2500 2500 2500 2500 2500 2500 SPL 2500 SPL 2500 600 2500 2500 2500 300 600 600 600 600 300 300 150 150 150 150 300 300 600 300 300 150 300 150 150
VE
STEM VALVES
FEED CONTROL VALVES 1 FULL LOAD FEED WATER CONTROL(MAIN & BYPASS) 14"X10" 2 LOW LOAD FEED WATER CONTROL 12"x8" SPRAY & SOOT BLOWER VALVES 1 SH SPRAY BLOCK 8" 2 SH STAGE SPRAY CONTROL 4"X3" 3 RH SPRAY MAIN BLOCK 4"X3" 4 RH BRANCH BLOCK 3" 5 RH SPRAY CONTROL 2.5" 6 SOOT BLOWER STEAM PR REDUCING VALVE 4"X2" PRDS VALVES 1 MS PRDS SPRAY CONTROL 2 MS PRDS SPRAY CONTROL 3 MS PRDS SPRAY CONTROL data not Availabe 4 CRH STEAM PRDS 5 CRH PRDS SPRAY CONTROL 6 CRH PRDS SPRAY CONTROL FEED PUMP RECIRCULATION VALVE 1 FEED PUMP MINIMUM RECIRCULATION VALVES HEATER DRAIN VALVES & CONDENSATE SYSTEM VALVES 1 PEGGING STEAM AUX STEAM HEADER TO DEAERATOR 12" 2 PEGGING STEAM FROM CRH TO DEAERATOR 16" 3 CONDENSATE PUMP MIN FLOW RECIRC VALVE 4" 4 CONDENSATE FLOW TO DEAERATOR 10" 5 CONDENSATE SPILL TO COND STORAGE TANK 8" 6 CONDENSATE NORMAL MAKE UP 4" 7 CONDENSATE EMERGENCY MAKE UP 8" 8 GSC MAIN FLOW 4" 9 HPH-6A & B NORMAL LEVEL 3" 10 HPH-6A & B EMERGENCY LEVEL 4" 11 HPH 5A & B NORMAL LEVEL 3" 12 HPH 5A & B EMERGENCY LEVEL 4" 13 LPH 3 NORMAL LEVEL 3" 14 LPH 3 EMERGENCY LEVEL 3" 15 LPH 2 NORMAL LEVEL 6" 16 LPH 2 EMERGENCY LEVEL 6" 17 LPH 1 NORMAL LEVEL 8" 18 LPH 1 EMERGENCY LEVEL 8" 19 VALVE GLAND SEALING PRESSURE CONTROL 2" 20 EQUIPMENT COOLING WATR DIFFERENTIAL PR CONTROL 12" 21 DM WATER OVERHEAD LEVEL CONTROL 1.5" SCAPH CONTROL VALVES 1 SECONDARY SCAPH 8" 2 PRIMARY SCAPH 4"
L VALVES
Pressure Class 2500 2500 2500 2500 2500 2500 2500 2500 Operating Pressure (kg/cm2)(g) 360 360 340 340 340 340 340 213 Operating Temp (oC) 200 200 260 260 350 350 350 482
VE
STEM VALVES 300 600 600 300 300 300 150 600 600 600 300 600 300 300 300 300 300 300 300 150 300 300 300 20 57 47 47 47 10 10 47 57 57 34 34 4 4 3 3 3 3 47 10 10 20 20 295 410 47 47 50 40 40 50 230 240 190 190 110 110 90 90 60 60 50 40 46 250 250
FEED CONTROL VALVES 1 FULL LOAD FEED WATER CONTROL(MAIN & BYPASS) 14"X10" LOW LOAD FEED WATER CONTROL 2 FEED REGULATING VALVE IN HP BFP DISCH LINE-FULL LOAD 6"X4" SPRAY & SOOT BLOWER VALVES 1 SH SPRAY STAGE I BLOCK 6" 2 SH STAGE I SPRAY CONTROL 2.5" 3 SH SPRAY STAGE Ii BLOCK 3" 4 SH STAGE Ii SPRAY CONTROL 1.5" 5 RH SPRAY MAIN BLOCK 3" 6 RH BRANCH BLOCK 2" 7 RH SPRAY CONTROL 2" 8 SOOT BLOWER STEAM PR REDUCING VALVE 2" PRDS VALVES 1 MS PRDS SPRAY CONTROL 6"X4" 2 MS PRDS SPRAY CONTROL 1.5" 3 MS PRDS SPRAY CONTROL 1.5" 4 CRH STEAM PRDS 2.5" 5 CRH PRDS SPRAY CONTROL 1" 6 CRH PRDS SPRAY CONTROL 1" FEED PUMP RECIRCULATION VALVE 1 FEED PUMP MINIMUM RECIRCULATION VALVES 4"X2" HEATER DRAIN VALVES & CONDENSATE SYSTEM VALVES PEGGING STEAM AUX STEAM HEADER TO DEAERATOR 1 PEGGING STEAM FROM CRH TO DEAERATOR 2 MAIN CONDENSATE CONTROL 3 MAIN CONDENSATE CONTROL 4 EXCESS CONDENSATE DUMP CONTROL 5 GSC MIN FLOW RECIRCULATION 6 CONDENSATE FOR VALVE GLAND SEALING 7 HPH-6A NORMAL DRAIN TO HPH-5A 8 HPH-6B NORMAL DRAIN TO HPH-5B 9 HPH-6B ALT DRAIN TO FLASH TANK B 10 HPH-6A ALT DRAIN TO FLASH TANK B 11 HPH-5A NORMAL DRAIN TO DEAERATOR 12 HPH-5B NORMAL DRAIN TO DEAERATOR 13 HPH-5B ALT DRAIN TO FLASH TANK A 14 HPH-5A ALT DRAIN TO FLASH TANK A 15 LPH-3 NORMAL DRAIN TO LPH-2 16 LPH-3 ALT DRAIN TO LP FLASH TANK A 17 LPH-2 NORMAL DRAIN TO LPH-1 18 LPH-2 ALT DRAIN TO LP FLASH TANK -B 19 DEAERATOR OVERFLOW TO LP FLASH TANK 20 DM NORMAL MAKE UP TO HOT WELL 21 DM EMERGENCY MAKE UP TO HOT WELL 22 CRH TO AUX STEAM HEADER
L VALVES
Pressure Class 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 SPL 2500 SPL 2500 600 2500 2500 2500 Operating Pressure (kg/cm2)(g) 330 35 330 262 182 262 182 282 282 182 182 169 267 267 48 267 267 260 Operating Temp (oC) 248 111 248 260 260 350 350 350 350 350 450 545 170 170 360 170 170 250
VE
STEM VALVES 28.5 30 30 23 33 30.1 44 44 45.3 45.3 16.43 16.43 17.8 17.8 2.5 2.3 1 1.2 9 3.3 3.3 28.5 330 50 47 50 50 50 206 206 255.2 255.2 172 172 201 201 102 118 78 95 163 35 35 322
1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
FEED WATER SYSTEM 250 FEED CONTROL STATION 200 TDBFP-A PUMP RECIRCULATION 200 TDBFP-B PUMP RECIRCULATION 200 MDBFP PUMP RECIRCULATION CONDENSATE SYSTEM 150 CEP-1 PUMP RECIRCULATION 150 CEP-2 PUMP RECIRCULATION 150 CEP-3 PUMP RECIRCULATION 150 HOTWELL NORMAL MAKEUP 200 HOTWELL OVERFLOW TO CST 150 CONDENSER CURTAIN SPRAY 200 DEAERATOR PEGGING STEAM 150 DEAERATOR OVERFLOW 400 DEAERATOR LEVEL CONTROL 200 DEAERATOR LEVEL CONTROL 300 CRH TO TDBFP COMMON LINE HEATER DRAIN SYSTEM 150 HP HEATER- 8A TO 7A 150 HP HEATER- 8A TO FLASH TANK 150 HP HEATER- 8B TO 7B 150 HP HEATER- 8B TO FLASH TANK 200 HP HEATER- 7A TO 6A 200 HP HEATER- 7A TO FLASH TANK 200 HP HEATER- 7B TO 6B 200 HP HEATER- 7B TO FLASH TANK 250 HP HEATER- 6A TO DEAERATOR 250 HP HEATER- 6A TO FLASH TANK 250 HP HEATER- 6B TO DEAERATOR 250 HP HEATER- 6B TO FLASH TANK 150 LP HEATER- 4 TO 3 150 LP HEATER- 4 TO FLASH TANK 150 LP HEATER- 3 TO 2A/B 200 LP HEATER- 3 TO FLASH TANK 150 HP HEATER- 2A TO FLASH TANK 150 HP HEATER- 2B TO FLASH TANK 250 HP HEATER- 2A/B TO INLET OF 3 250 HP HEATER- 1A TO CONDENSER 250 HP HEATER- 1A TO COND.(EMER) 250 HP HEATER- 1B TO CONDENSER 250 HP HEATER- 1B TO COND.(EMER)
4500 4500 4500 4500 300 300 300 150 300 300 600 300 300 300 600 900 900 900 900 600 600 600 600 300 300 300 300 150 150 150 150 150 150 300 150 150 150 150
ES
Operating Outlet Operating Pressure Pressure Temp (oC) (kg/cm2)(g) (kg/cm2)(g)